ZC receives no Data from the ADIRS
TASK 21-63-00-810-820-A
ZC receives no Data from the ADIRS
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-63-00-710-089-A ** ON A/C NOT FOR ALL
Subtask 21-63-00-810-082-A ** ON A/C NOT FOR ALL
Subtask 21-63-00-860-069-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:25:01 UTC
ZC receives no Data from the ADIRS
1. Possible Causes
- ZONE CONTROLLER [8HK]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-63-00-710-004 | Operational Test of the Cockpit and Cabin Temperature Control with CFDS/MCDU |
| ASM 216303 | |
| AMM 21-63-34-000-001 | Removal of the Zone Controller |
| AMM 21-63-34-400-001 | Installation of the Zone Controller |
| AMM 34-13-00-740-002 | INTERFACE TEST of the ADR |
| ASM 341301 |
Subtask 21-63-00-710-089-A ** ON A/C NOT FOR ALL
A. Test
(1) On the ADIRS CDU panel 20VU:
4. Fault Isolation(1) On the ADIRS CDU panel 20VU:
- make sure that the 3 OFF/NAV/ATT switches are in the NAV position and that the ADR 1, ADR 2 and ADR 3 pushbutton switches are in the on position (with the FAULT and OFF legends off).
NOTE: If a fault is detected, the ZC gives a fault code for shop maintenance in addition to the related CFDS message(s). For detailed information see the applicable Page Block 301.
Subtask 21-63-00-810-082-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message NO DATA FROM ADIRS:
Subtask 21-63-00-710-090-A ** ON A/C NOT FOR ALL - replace the ZONE CONTROLLER [8HK] AMM 21-63-34-000-001 and AMM 21-63-34-400-001.
- do a check and repair the wiring if necessary of the signal DATA BUS £4 from the ADIRS 3 (1FP3) to the ZC (8HK) ASM 216303 and ASM 341301.
- do the INTERFACE test of the ADR system AMM 34-13-00-740-002.
B. Do the test as given in the Para. 3.A.
5. Close-upSubtask 21-63-00-860-069-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.