CIDS receives no Data from the ZC
TASK 21-63-00-810-859-A
CIDS receives no Data from the ZC
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-63-00-710-149-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 21-63-00-810-154-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:25:05 UTC
CIDS receives no Data from the ZC
1. Possible Causes
- wiring
- DIR-CIDS, 1 [101RH]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-63-00-710-004 | Operational Test of the Cockpit and Cabin Temperature Control with CFDS/MCDU |
| ASM 216301 | |
| AMM 23-73-00-740-003 | BITE-Test of the Cabin Intercommunication Data System (CIDS) through the PTP |
| AMM 23-73-34-000-001 | Removal of the CIDS Director |
| AMM 23-73-34-400-001 | Installation of the CIDS Director |
Subtask 21-63-00-710-149-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 21-63-00-810-154-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 21-63-00-810-155-A ** ON A/C NOT FOR ALL B. If the test gives the maintenance message ZC(8HK)/SDAC1(1WV1)/DIR1(101RH):
(2) If the fault continues:
(a) Do a check and repair if necessary the connector pin at the connector 8HK/BA for the CIDS option.
(a) Do a check and repair the ARINC 429 wiring as necessary of the signal INPUT Zone Controller from: ASM 216301
Replace the DIR-CIDS, 1 [101RH] AMM 23-73-34-000-001 and AMM 23-73-34-400-001.
Subtask 21-63-00-710-150-A ** ON A/C NOT FOR ALL - do the operational test of the cockpit and cabin temperature-control system with CFDS/MCDU AMM 21-63-00-710-004.
(2) If the fault continues:
(a) Do a check and repair if necessary the connector pin at the connector 8HK/BA for the CIDS option.
- Pin BA3 to ground.
(a) Do a check and repair the ARINC 429 wiring as necessary of the signal INPUT Zone Controller from: ASM 216301
- the CIDS Director (101RH) connector AA/6A to the Zone Controller (8HK) connector AA/3A.
- the CIDS Director (101RH) connector AA/6B to the Zone Controller (8HK) connector AA/B3.
Replace the DIR-CIDS, 1 [101RH] AMM 23-73-34-000-001 and AMM 23-73-34-400-001.
C. Do the test given in Para. 3.