W DOC AIRBUS | TSM A320F

CIDS receives no Data from the ZC


TASK 21-63-00-810-859-A
CIDS receives no Data from the ZC


1. Possible Causes
  • wiring
  • DIR-CIDS, 1 [101RH]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-63-00-710-004
Operational Test of the Cockpit and Cabin Temperature Control with CFDS/MCDU
ASM 216301
AMM 23-73-00-740-003
BITE-Test of the Cabin Intercommunication Data System (CIDS) through the PTP
AMM 23-73-34-000-001
Removal of the CIDS Director
AMM 23-73-34-400-001
Installation of the CIDS Director
3. Fault Confirmation
Subtask 21-63-00-710-149-A ** ON A/C NOT FOR ALL
A. Do the bite test of the CIDS AMM 23-73-00-740-003.
4. Fault Isolation
Subtask 21-63-00-810-154-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 21-63-00-810-155-A ** ON A/C NOT FOR ALL
B. If the test gives the maintenance message ZC(8HK)/SDAC1(1WV1)/DIR1(101RH):
  • do the operational test of the cockpit and cabin temperature-control system with CFDS/MCDU AMM 21-63-00-710-004.
   (1) If the test gives a different maintenance message, do the related trouble shooting procedure.
   (2) If the fault continues:
     (a) Do a check and repair if necessary the connector pin at the connector 8HK/BA for the CIDS option.
  • Pin BA3 to ground.
   (3) If the fault continues:
     (a) Do a check and repair the ARINC 429 wiring as necessary of the signal INPUT Zone Controller from: ASM 216301
  • the CIDS Director (101RH) connector AA/6A to the Zone Controller (8HK) connector AA/3A.
  • the CIDS Director (101RH) connector AA/6B to the Zone Controller (8HK) connector AA/B3.
   (4) If the fault continues:
Replace the DIR-CIDS, 1 [101RH] AMM 23-73-34-000-001 and AMM 23-73-34-400-001.
Subtask 21-63-00-710-150-A ** ON A/C NOT FOR ALL
C. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:25:05 UTC