Pack 2 Trim Air Check Valve Fault
TASK 21-63-00-810-851-A
Pack 2 Trim Air Check Valve Fault
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-63-00-710-136-A 4. Fault Isolation
Subtask 21-63-00-810-142-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:05 UTC
Pack 2 Trim Air Check Valve Fault
1. Possible Causes
- P2 CHECK VALVE TRIM AIR [19HM]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-63-00-710-005 | Operational Test of the Trim Air Check-Valves |
| AMM 21-63-42-000-001 | Removal of the Trim-Air Check Valves |
| AMM 21-63-42-400-001 | Installation of the Trim-Air Check Valves |
Subtask 21-63-00-710-136-A 4. Fault Isolation
Subtask 21-63-00-810-142-A
A. If during the test the pack 2 discharge temperature increases:
Subtask 21-63-00-720-054-A - replace the P2 CHECK VALVE TRIM AIR [19HM] AMM 21-63-42-000-001 and AMM 21-63-42-400-001.
B. Do the test given in Para. 3.