COCKPIT AND CABIN TEMPERATURE CONTROL - TASK SUPPORTING DATA
** ON A/C NOT FOR ALL
A. CFDS Fault Information
Additional information about a failed component is available in the MCDU CAB TEMP CONT menu.
The related LAST LEG REPORT page shows:
Additional information about a failed component is available in the MCDU CAB TEMP CONT menu.
The related LAST LEG REPORT page shows:
- the date and time when the fault occured,
- the ATA number of the component,
- the FIN of the component.
B. Troubleshooting Data
If a fault is detected during the ZC initiated test, a fault code for shop maintenance is given in addition to the related CFDS message.
The subsequent table shows the possible fault codes with their attached fault origns:
The trouble shooting data give additional information for shop maintenance.
If a fault is detected during the ZC initiated test, a fault code for shop maintenance is given in addition to the related CFDS message.
The subsequent table shows the possible fault codes with their attached fault origns:
The trouble shooting data give additional information for shop maintenance.
| .-------.--------------------------------------.------------------------------. |
| ! FAULT ! FAULT ORIGIN ! CFDS MESSAGE ! |
| ! CODE ! ! ! |
| !-------!--------------------------------------!------------------------------! |
| ! 10 ! TAV CKPT MOTOR, MECHANIC ! TRIM VALVE CKPT ! |
| !-------!--------------------------------------!------------------------------! |
| ! 11 ! TAV FWD CAB MOTOR, MECHANIC ! TRIM VALVE FWD CAB ! |
| !-------!--------------------------------------!------------------------------! |
| ! 12 ! TAV AFT CAB MOTOR, MECHANIC ! TRIM VALVE AFT CAB ! |
| !-------!--------------------------------------!------------------------------! |
| ! 13 ! TAPRV FAILED OPEN/CLOSED, SOLENOID ! TRIM AIR PRESS VALVE ! |
| ! ! REDUCED ! ! |
| !-------!--------------------------------------!------------------------------! |
| ! 14 ! CKPT TEMPERATURE SENSOR ! TEMP SENSOR CKPT ! |
| !-------!--------------------------------------!------------------------------! |
| ! 15 ! FWD CAB TEMPERATURE SENSOR ! TEMP SENSOR FWD CAB ! |
| !-------!--------------------------------------!------------------------------! |
| ! 16 ! AFT CAB TEMPERATURE SENSOR ! TEMP SENSOR AFT CAB ! |
| !-------!--------------------------------------!------------------------------! |
| ! 17 ! CKPT DUCT TEMPERATURE SENSOR ! TEMP SENSOR CKPT DUCT ! |
| !-------!--------------------------------------!------------------------------! |
| ! 18 ! FWD CAB DUCT TEMPERATURE SENSOR ! TEMP SENSOR FWD CAB DUCT ! |
| !-------!--------------------------------------!------------------------------! |
| ! 19 ! AFT CAB DUCT TEMPERATURE SENSOR ! TEMP SENSOR AFT CAB DUCT ! |
| !-------!--------------------------------------!------------------------------! |
| ! 1D ! L/H MIXER MANIFOLD TEMP SENSOR ! TEMP SENSOR L/H MIXER ! |
| !-------!--------------------------------------!------------------------------! |
| ! 1E ! R/H MIXER MANIFOLD TEMP SENSOR ! TEMP SENSOR R/H MIXER ! |
| !-------!--------------------------------------!------------------------------! |
| ! 1F ! CKPT TEMPERATURE SELECTOR ! CKPT TEMP SELECTOR ! |
| !-------!--------------------------------------!------------------------------! |
| ! 20 ! FWD CAB TEMPERATURE SELECTOR ! FWD CAB TEMP SELECTOR ! |
| !-------!--------------------------------------!------------------------------! |
| ! 21 ! AFT CAB TEMPERATURE SELECTOR ! AFT CAB TEMP SELECTOR ! |
| !-------!--------------------------------------!------------------------------! |
| ! 22 ! G & T FAN FAULT/OFF ! GALY & TOIL FAN OR SPLY ! |
| !-------!--------------------------------------!------------------------------! |
| ! 23 ! HIGH HOT AIR PRESSURE ! TRIM AIR PRESS VALVE OR ! |
| ! ! ! PRESS SWITCH ! |
| !-------!--------------------------------------!------------------------------! |
| ! 24 ! FLOW SELECTOR ! FLOW SEL ! |
| !-------!--------------------------------------!------------------------------! |
| ! 2E ! ZC 429 RCV EXT ! NO DATA FROM CFDS ! |
| !-------!--------------------------------------!------------------------------! |
| ! 2F ! ZC 429 RCV EXT ! NO DATA FROM ADIRS ! |
| !-------!--------------------------------------!------------------------------! |
| ! 30 ! ZC RAM, EPROM, CPU, A/D CONVERTER, ! ZONE CONT ! |
| ! ! DISCRETE INPUTS, DISCRETE OUTPUTS, ! ! |
| ! ! 429 XTR INT, 429 XTR EXT, PWR SPLY, ! ! |
| ! ! TAV DRIVE OUTPUTS, 429 RCV INT, ! ! |
| ! ! WATCHDOG BACKUP SWITCHING ! ! |
| !-------!--------------------------------------!------------------------------! |
| ! 31 ! WRG SHORT CIRCUIT ! ZONE CONT OR SENSOR ! |
| ! ! ! SUPPLY SHORT ! |
| !-------!--------------------------------------!------------------------------! |
| ! 34 ! TAPRV FAILED OPEN ! ZONE CONT ! |
| !-------!--------------------------------------!------------------------------! |
| ! 38 ! TAPRV DRIVE ! ZONE CONT ! |
| !-------!--------------------------------------!------------------------------! |
| ! 39 ! RECIRCULATION FAN 1 ! RECIRC FAN 1 OR SPLY ! |
| !-------!--------------------------------------!------------------------------! |
| ! 3A ! RECIRCULATION FAN 2 ! RECIRC FAN 2 OR SPLY ! |
| !-------!--------------------------------------!------------------------------! |
| ! 3B ! FWD CARGO VENTILATION ! FWD CARGO FAN OR SPLY ! |
| !-------!--------------------------------------!------------------------------! |
| ! 3C ! AFT CARGO VENTILATION ! AFT CARGO FAN OR SPLY ! |
| !-------!--------------------------------------!------------------------------! |
| ! 3D ! LH ANTI ICE SYSTEM ! WAI FILTER OR VALVE 9DL ! |
| !-------!--------------------------------------!------------------------------! |
| ! 3E ! RH ANTI ICE SYSTEM ! WAI FILTER OR VALVE 10DL ! |
| !-------!--------------------------------------!------------------------------! |
| ! 3F ! LH ANTI ICE SYSTEM ! NO BLEED AIR ENG 1 ! |
| !-------!--------------------------------------!------------------------------! |
| ! 40 ! RH ANTI ICE SYSTEM ! NO BLEED AIR ENG 2 ! |
| !-------!--------------------------------------!------------------------------! |
| ! 41 ! MIXER FLAP DISAGREE ! MIXER FLAP DRIVE OR SPLY ! |
| !-------!--------------------------------------!------------------------------! |
| ! 43 ! P 1 COMPRESSOR TEMP SENSOR / P 1 ! PC1 COMP TEMP/OVHT SENSOR ! |
| ! ! COMPRESSOR OVHT SENSOR DISAGREE ! DISAGREE ! |
| !-------!--------------------------------------!------------------------------! |
| ! 44 ! P 2 COMPRESSOR TEMP SENSOR / P 2 ! PC2 COMP TEMP/OVHT SENSOR ! |
| ! ! COMPRESSOR OVHT SENSOR DISAGREE ! DISAGREE ! |
| !-------!--------------------------------------!------------------------------! |
| ! 49 ! PC 1 MAIN DC SUPPLY ! NO 28V ON PACK 1 MAIN ! |
| !-------!--------------------------------------!------------------------------! |
| ! 4A ! PC 2 MAIN DC SUPPLY ! NO 28V ON PACK 2 MAIN ! |
| !-------!--------------------------------------!------------------------------! |
| ! 4B ! PC 1 SECD DC SUPPLY ! NO 28V ON PACK 1 SECD ! |
| !-------!--------------------------------------!------------------------------! |
| ! 4C ! PC 2 SECD DC SUPPLY ! NO 28V ON PACK 2 SECD ! |
| !-------!--------------------------------------!------------------------------! |
| ! 4E ! ZC MAIN DC SUPPLY ! NO 28V ON ZONE MAIN ! |
| !-------!--------------------------------------!------------------------------! |
| ! 4F ! ZC SECD DC SUPPLY ! NO 28V ON ZONE SECD ! |
| !-------!--------------------------------------!------------------------------! |
| ! 52 ! PACK 1 PRESSURE INLET SENSOR ! P1 PRESS INL SENSOR ! |
| !-------!--------------------------------------!------------------------------! |
| ! 53 ! PACK 2 PRESSURE INLET SENSOR ! P2 PRESS INL SENSOR ! |
| !-------!--------------------------------------!------------------------------! |
| ! 54 ! PACK 1 DISCHARGE OVERHEAT ! P1 AIR CYCLE MACH CHECK ! |
| !-------!--------------------------------------!------------------------------! |
| ! 55 ! PACK 2 DISCHARGE OVERHEAT ! P2 AIR CYCLE MACH CHECK ! |
| !-------!--------------------------------------!------------------------------! |
| ! 56 ! PACK 1 COMPRESSOR TEMP SENSOR ! P1 COMP TEMP SENSOR ! |
| !-------!--------------------------------------!------------------------------! |
| ! 57 ! PACK 2 COMPRESSOR TEMP SENSOR ! P2 COMP TEMP SENSOR ! |
| !-------!--------------------------------------!------------------------------! |
| ! 58 ! PACK 1 COMPRESSOR OVERHEAT SENSOR ! P1 COMP OVHT SENSOR ! |
| !-------!--------------------------------------!------------------------------! |
| ! 59 ! PACK 2 COMPRESSOR OVERHEAT SENSOR ! P2 COMP OVHT SENSOR ! |
| !-------!--------------------------------------!------------------------------! |
| ! 5A ! PACK 1 OUTLET TEMPERATURE SENSOR ! P1 OUTLET TEMP SENSOR ! |
| !-------!--------------------------------------!------------------------------! |
| ! 5B ! PACK 2 OUTLET TEMPERATURE SENSOR ! P2 OUTLET TEMP SENSOR ! |
| !-------!--------------------------------------!------------------------------! |
| ! 5C ! PACK 1 WATER EXTRACTOR TEMP SENSOR ! P1 WATER EX TEMP SENSOR ! |
| !-------!--------------------------------------!------------------------------! |
| ! 5D ! PACK 2 WATER EXTRACTOR TEMP SENSOR ! P2 WATER EX TEMP SENSOR ! |
| !-------!--------------------------------------!------------------------------! |
| ! 5E ! PACK 1 RAI MOTOR, POT, MECHANIC, ! P1 RAM AIR IN ACTUATOR ! |
| ! ! LIMIT SWITCH ! ! |
| !-------!--------------------------------------!------------------------------! |
| ! 5F ! PACK 2 RAI MOTOR, POT, MECHANIC, ! P2 RAM AIR IN ACTUATOR ! |
| ! ! LIMIT SWITCH ! ! |
| !-------!--------------------------------------!------------------------------! |
| ! 62 ! PACK 1 BPV MOTOR, POT, MECHANIC, ! P1 BYPASS VALVE ! |
| ! ! LIMIT SWITCH ! ! |
| !-------!--------------------------------------!------------------------------! |
| ! 63 ! PACK 2 BPV MOTOR, POT, MECHANIC, ! P2 BYPASS VALVE ! |
| ! ! LIMIT SWITCH ! ! |
| !-------!--------------------------------------!------------------------------! |
| ! 64 ! PACK 1 FCV MOTOR, POT, MECHANIC ! P1 FLOW CONT VALVE ! |
| !-------!--------------------------------------!------------------------------! |
| ! 65 ! PACK 2 FCV MOTOR, POT, MECHANIC ! P2 FLOW CONT VALVE ! |
| !-------!--------------------------------------!------------------------------! |
| ! 66 ! PACK 1 AIV PERMANENT OPEN/CLOSED ! P1 CONT OR ANTI ICE VALVE ! |
| !-------!--------------------------------------!------------------------------! |
| ! 67 ! PACK 2 AIV PERMANENT OPEN/CLOSED ! P2 CONT OR ANTI ICE VALVE ! |
| !-------!--------------------------------------!------------------------------! |
| ! 68 ! PACK 1 PRESSURE (FLOW) SENSOR ! P1 FLOW SENSOR ! |
| !-------!--------------------------------------!------------------------------! |
| ! 69 ! PACK 2 PRESSURE (FLOW) SENSOR ! P2 FLOW SENSOR ! |
| !-------!--------------------------------------!------------------------------! |
| ! 6A ! PC 1 RAM, EPROM, CPU, A/D CONVERTER, ! P1 CONT ! |
| ! ! DISCRETE INPUTS, 429 RCV, BPV DRIVE ! ! |
| ! ! OUTPUT ! ! |
| !-------!--------------------------------------!------------------------------! |
| ! 6B ! PC 2 RAM, EPROM, CPU, A/D CONVERTER, ! P2 CONT ! |
| ! ! DISCRETE INPUTS, 429 RCV, BPV DRIVE ! ! |
| ! ! OUTPUT ! ! |
| !-------!--------------------------------------!------------------------------! |
| ! 6C ! ZC AC SUPPLY ! AC SUPPLY ZONE CONT ! |
| !-------!--------------------------------------!------------------------------! |
| ! 6D ! PC 1 NO TEST ! NO TEST RESULT RECEPTION ! |
| ! ! ! FROM P1 CONT ! |
| !-------!--------------------------------------!------------------------------! |
| ! 6E ! PC 2 NO TEST ! NO TEST RESULT RECEPTION ! |
| ! ! ! FROM P2 CONT ! |
| !-------!--------------------------------------!------------------------------! |
| ! 6F ! PRESSURE SWITCH OUTPUT ! PRESS SWITCH ! |
| !-------!--------------------------------------!------------------------------! |
| ! 7B ! ZC 429 XTR ! CHECK BUS ZONE CONT TO ! |
| ! ! ! P1 CONT + P2 CONT ! |
| !-------!--------------------------------------!------------------------------! |
| ! 7C ! ZC DC SUPPLY ! DC SUPPLY ZONE CONT ! |
| !-------!--------------------------------------!------------------------------! |
| ! 7D ! PC 1 DC SUPPLY ! DC SUPPLY P1 CONT ! |
| !-------!--------------------------------------!------------------------------! |
| ! 7E ! PC 2 DC SUPPLY ! DC SUPPLY P2 CONT ! |
| !-------!--------------------------------------!------------------------------! |
| ! 76 ! RECIRCULATION FAN 1 AND 2 ! RECIRC FAN 1 AND 2 OR SPLY ! |
| !-------!--------------------------------------!------------------------------! |
| ! 77 ! L/H AND R/H MIXER UNIT TEMP SENSORS ! TEMP SENSOR L/H AND R/H MIXER! |
| !_______!______________________________________!______________________________! |
Cockpit and Cabin Temperature Control - Block Diagram