AFT Cabin Duct Overheat Detection
TASK 21-63-00-810-825-A
AFT Cabin Duct Overheat Detection
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-63-00-710-099-A ** ON A/C NOT FOR ALL
Subtask 21-63-00-810-093-B ** ON A/C NOT FOR ALL
Subtask 21-63-00-860-074-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:03 UTC
AFT Cabin Duct Overheat Detection
1. Possible Causes
- TEMP SENSOR AFT CAB DUCT [17HK]
- wiring
- TRIM VALVE AFT CAB [13HK]
- TRIM AIR PRESS VALVE [14HK]
- CONT-AIR COND SYSTEM 1 [47HH]
- ZONE CONTROLLER [8HK]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-61-34-000-002 | Removal of the Air-Conditioning System Controller |
| AMM 21-61-34-400-002 | Installation of the Air-Conditioning System Controller |
| AMM 21-63-00-710-004 | Operational Test of the Cockpit and Cabin Temperature Control with CFDS/MCDU |
| ASM 216302 | |
| ASM 216303 | |
| AMM 21-63-15-000-001 | Removal of the Duct Temperature Sensors |
| AMM 21-63-15-400-001 | Installation of the Duct Temperature Sensors |
| AMM 21-63-34-000-001 | Removal of the Zone Controller |
| AMM 21-63-34-400-001 | Installation of the Zone Controller |
| AMM 21-63-51-000-001 | Removal of the Trim Air Valve |
| AMM 21-63-51-400-001 | Installation of the Trim Air Valve |
| AMM 21-63-52-000-001 | Removal of the Pressure Regulating Valve |
| AMM 21-63-52-400-001 | Installation of the Pressure Regulating Valve |
Subtask 21-63-00-710-099-A ** ON A/C NOT FOR ALL
A. Do the operational test of the cockpit and cabin temperature-control system with CFDS/MCDU AMM 21-63-00-710-004.
Subtask 21-63-00-710-099-B ** ON A/C NOT FOR ALL NOTE: If a fault is detected, the ZC gives a fault code for shop maintenance in addition to the related CFDS message(s). For detailed information see the applicable Page Block 301.
A. Do the operational test of the cockpit and cabin temperature-control system with CFDS/MCDU AMM 21-63-00-710-004.
4. Fault IsolationSubtask 21-63-00-810-093-B ** ON A/C NOT FOR ALL
A. If the test confirms the fault:
(1) If the resistance values are out of the specified limits:
Subtask 21-63-00-810-093-C ** ON A/C NOT FOR ALL - do a check that the resistance of the AFT cabin-duct temperature sensor (17HK) measured between connector A/E and A/F and connector A/C and A/D is in these limits ASM 216303:
| Temp (Deg.C) | OHMS |
|---|---|
| + 10 | 18820 +/- 5 % |
| + 18 | 13340 +/- 5 % |
| + 25 | 10000 +/- 5 % |
| + 30 | 8197 +/- 5 % |
| + 40 | 5598 +/- 5 % |
| + 50 | 3903 +/- 5 % |
- replace the TEMP SENSOR AFT CAB DUCT [17HK] AMM 21-63-15-000-001 and AMM 21-63-15-400-001.
- do a check and repair the wiring ASM 216302 from:
- the SENSOR-DUCT TEMPERATURE,AFT CABIN (17HK) to the ACSC2 (57HH) and,
- the SENSOR-DUCT TEMPERATURE,AFT CABIN (17HK) to ground.
- replace the TRIM VALVE AFT CAB [13HK] AMM 21-63-51-000-001 and AMM 21-63-51-400-001.
- do a check and repair the wiring ASM 216302 from:
- the VALVE-TRIM AIR,AFT CABIN (13HK) to the ACSC2 (57HH) and,
- the VALVE-TRIM AIR,AFT CABIN (13HK) to ground.
- replace the TRIM AIR PRESS VALVE [14HK] AMM 21-63-52-000-001 and AMM 21-63-52-400-001.
- do a check and repair the wiring ASM 216303 from:
- the VALVE-PRESSURE REGULATING (14HK) to the ACSC1 (47HH) and,
- the VALVE-PRESSURE REGULATING(14HK) to ground.
- replace the CONT-AIR COND SYSTEM 1 [47HH] AMM 21-61-34-000-002 and AMM 21-61-34-400-002.
A. If the test confirms the fault:
(1) If the resistance values are out of the specified limits:
Subtask 21-63-00-810-107-B - do a check that the resistance of the AFT cabin-duct temperature sensor (17HK) measured between connector A/E and A/F and connector A/C and A/D is in these limits ASM 216303:
| Temp (Deg.C) | OHMS |
|---|---|
| + 10 | 18820 +/- 5 % |
| + 18 | 13340 +/- 5 % |
| + 25 | 10000 +/- 5 % |
| + 30 | 8197 +/- 5 % |
| + 40 | 5598 +/- 5 % |
| + 50 | 3903 +/- 5 % |
- replace the TEMP SENSOR AFT CAB DUCT [17HK] AMM 21-63-15-000-001 and AMM 21-63-15-400-001.
- do a check and repair the wiring ASM 216303 from:
- the SENSOR-DUCT TEMPERATURE,AFT CABIN (17HK) to the ZC (8HK) and,
- the SENSOR-DUCT TEMPERATURE,AFT CABIN (17HK) to ground.
- replace the TRIM VALVE AFT CAB [13HK] AMM 21-63-51-000-001 and AMM 21-63-51-400-001.
- do a check and repair the wiring ASM 216303 from:
- the VALVE-TRIM AIR,AFT CABIN (13HK) to the ZC (8HK) and,
- the VALVE-TRIM AIR,AFT CABIN (13HK) to ground.
- replace the TRIM AIR PRESS VALVE [14HK] AMM 21-63-52-000-001 and AMM 21-63-52-400-001.
- do a check and repair the wiring ASM 216303 from:
- the VALVE-PRESSURE REGULATING (14HK) to the ZC (8HK) and,
- the VALVE-PRESSURE REGULATING(14HK) to ground.
- replace the ZONE CONTROLLER [8HK] AMM 21-63-34-000-001 and AMM 21-63-34-400-001.
B. If the test gives the maintenance message TEST OK, but on the ECAM upper DU the warning COND AFT CAB DUCT OVHT comes on:
Subtask 21-63-00-710-100-A - do a check of the AFT cabin-duct inlet temperature on the ECAM COND page.
- replace the TEMP SENSOR AFT CAB DUCT [17HK] AMM 21-63-15-000-001 and AMM 21-63-15-400-001.
C. Do the test as given in the Para. 3.A.
5. Close-upSubtask 21-63-00-860-074-A
A. Put the aircraft back to its initial configuration.