W DOC AIRBUS | AMM A320F

Operational Test of the FADEC on the Ground (with Engine Motoring) [CFMB]


TASK 73-29-00-710-040-B
Operational Test of the FADEC on the Ground (with Engine Motoring)


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
WARNING: MAKE SURE THAT ALL ENGINE OPERATING AREAS ARE AS CLEAN AS POSSIBLE. ALL RAMPS, TAXIWAYS, RUNWAYS AND OTHER OPERATING AREAS MUST BE VERY CLEAN TO PREVENT BAD DAMAGE TO THE ENGINE, AIRCRAFT AND PERSONS IN THE AREA.
WARNING: DO NOT TRY TO STOP THE FAN FROM TURNING BY HAND. THIS CAN CAUSE INJURY TO THE PERSONS AND DAMAGE TO THE EQUIPMENT.
WARNING: MAKE SURE THAT THE LANDING GEAR GROUND SAFETIES AND THE WHEEL CHOCKS ARE IN POSITION. MOVEMENT OF THE AIRCRAFT CAN BE DANGEROUS.
WARNING: MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
CAUTION: - SEE THE APPLICABLE FIGURE FOR WIND LIMIT RESTRICTIONS WHEN THE ENGINE OPERATES.
  • NATURAL WINDS AND IRREGULAR FORCES FROM SUDDEN GUSTS INCREASE THE DANGEROUS AREA.
  • DO NOT GO ABOVE OPEN COWLING LIMITATIONS WHEN YOU DO THE TESTS.
  • THE OPERATOR MUST FULLY KNOW ALL THE OPERATING LIMITS AND PROCEDURES BEFORE THE ENGINE OPERATES.
CAUTION: DO NOT REPLACE AN IDLE LEAK CHECK BY A MOTORING TEST. YOU CANNOT DETECT POTENTIAL OIL LEAKS WITH A MOTORING TEST. IF YOU DO A MOTORING TEST INSTEAD OF AN IDLE LEAK CHECK, YOU CAN CAUSE AN ENGINE SHUTDOWN.
CAUTION: MAKE SURE THAT THERE IS NO HYDRAULIC GROUND POWER SUPPLY CONNECTED TO THE AIRCRAFT WHEN YOU DO THIS PROCEDURE. IF A HYDRAULIC GROUND POWER SUPPLY IS CONNECTED, THERE IS A RISK OF DAMAGE TO THE ENGINE PUMPS.
ZONE: 210
ZONE: 400
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
GROUND AIR-SUPPLY UNIT(HIGH PRESSURE)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
400
POWER PLANT, NACELLES AND PYLONS
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 10-11-00-555-013-A
Installation of the Aircraft Protection Equipment
TASK 10-11-00-555-014-A
Removal of the Aircraft Protection Equipment
TASK 12-12-29-611-001-A
Fill the Hydraulic Fluid Reservoir with a Hand Pump
TASK 12-12-29-611-002-A
Fill the Hydraulic Fluid Reservoir with a Hydraulic Service Cart
TASK 12-13-79-610-002-A
Check oil level and replenish Check Pop Out Indicator of EMCD (Electrical Master Chip Detector)
TASK 12-13-79-610-002-A-01
Check oil level and replenish (Pressure Filling)
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 29-14-00-614-002-A
Pressurization of the Hydraulic Reservoirs through the Ground Connector
TASK 29-14-00-614-002-A-01
Pressurization of the Hydraulic Reservoirs with the Auxiliary Power Unit (APU)
TASK 31-32-00-860-012-A
Procedure to Get Access to the SYSTEM REPORT/TEST/ENG Page
TASK 36-12-00-860-001-A
Pressurization of the Bleed System with the APU
TASK 36-12-00-860-002-A
Pressurization of the Bleed System through the HP Ground Connector
TASK 78-36-00-010-040-B
Opening of the Thrust Reverser Doors
3. Job Set-up
Subtask 73-29-00-869-050-A ** ON A/C NOT FOR ALL
A. Safety Precautions
WARNING: DO NOT TRY TO STOP THE FAN FROM TURNING BY HAND. THIS CAN CAUSE INJURY TO THE PERSONS AND DAMAGE TO THE EQUIPMENT.
CAUTION: REMOVE THE PROTECTIVE COVERS FROM THE PROBES BEFORE YOU DO THIS PROCEDURE. IF YOU DO NOT REMOVE THEM, THE PROBES AND PROTECTIVE COVERS CAN BECOME DAMAGED OR BURNED.
   (1) Remove the protective covers from the probes and sensors before you do this procedure (Ref. AMM TASK 10-11-00-555-014).
   (2) Make sure that:
  • the engine,
  • the air intake,
  • the exhaust areas,
    are clear of equipment, persons, tools, blockages, all unwanted objects and ice.
   (3) Make sure that the fan parts and the engine inlet area are in the correct condition. Make a full inspection of the fan blades.
   (4) Examine the external surfaces of the cowl. Make sure that there are no leaks of fuel and oil at the drain ports.
Subtask 73-29-00-861-050-A ** ON A/C NOT FOR ALL
B. Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
Subtask 73-29-00-860-050-A ** ON A/C NOT FOR ALL
C. Do a check of the Aircraft Condition:
   (1) On the lower display unit of the ECAM system on the ENG page:
     (a) make sure that the oil level is correct.
       1 If it is necessary, do the servicing of the tank (Ref. AMM TASK 12-13-79-610-002).
   (2) If you let the engine stay open to freezing rain, ice or snow ; make sure that the fan turns freely.
     (a) If the fan does not turn freely, you must make the engine warm with hot air. You must do this step before an engine motoring.
   (3) Make sure that the hydraulic reservoirs are pressurized (Ref. AMM TASK 29-14-00-614-002).
   (4) Make sure that the level of the hydraulic fluid in the reservoir is correct. If necessary, fill the reservoir (Ref. AMM TASK 12-12-29-611-001) or (Ref. AMM TASK 12-12-29-611-002).
NOTE: You can do this test with the thrust reverser doors in open position (35 deg.) (Ref. AMM TASK 78-36-00-010-040).
Subtask 73-29-00-865-050-A ** ON A/C NOT FOR ALL
D. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUENGINE/1 AND 2/IGN/SYS A1JHA03
FOR FIN: 1000EM1 (ENGINE1)
49VUFUEL/LP VALVE/MOT1/ENG11QGA08
49VUENGINE/1/FADEC A/AND EIU 12KS1A04
49VUENGINE/1/HP FUEL SOV1KC1A01
121VUFUEL/LP VALVE/MOT2/ENG13QGM25
121VUENGINE/IGN/ENG1/SYS B3JH1P41
121VUENGINE/IGN/ENG1/SYS A BAT2JH1P39
121VUENGINE/ENG1/FADEC B/AND EIU 14KS1R41
FOR FIN: 1000EM2 (ENGINE2)
49VUFUEL/LP VALVE/MOT1/ENG22QGA09
49VUENGINE/2/FADEC A/AND EIU 22KS2A05
49VUENGINE/2/HP FUEL SOV1KC2A02
121VUFUEL/LP VALVE/MOT2/ENG24QGM26
121VUENGINE/IGN/ENG2/SYS B3JH2P42
121VUENGINE/IGN/ENG2/SYS A BAT2JH2P40
121VUENGINE/ENG2/FADEC B4KS2Q40
Subtask 73-29-00-941-050-A ** ON A/C NOT FOR ALL
E. Connect a GROUND AIR-SUPPLY UNIT(HIGH PRESSURE) to the HP connectors or use the air from the APU (Ref. AMM TASK 36-12-00-860-001) or (Ref. AMM TASK 36-12-00-860-002). Make sure that the pressure of the air supply is between 25 psi (1.7 bar) and 55 psi (3.8 bar).
Subtask 73-29-00-860-051-A ** ON A/C NOT FOR ALL
F. Do a check of the Panels to Prepare for Test.
   (1) On the AIR COND panel 30VU, set the PACK 1/ENG 1 BLEED and PACK 2/ENG 2 BLEED pushbutton switches to OFF.
   (2) On the maintenance panel 50VU, push then release the FADEC GND PWR 1(2) pushbutton switch (on this pushbutton switch, the ON legend is on).
   (3) On the left or right MCDU, get the SYSTEM REPORT/TEST, ENG page (Ref. AMM TASK 31-32-00-860-012).
   (4) On the fuel part of the fuel control panel 40VU, push all the PUMPS pushbutton switches. On the pushbutton switches, the OFF legend go off.
   (5) On the ADIRS control display panel set the ADIRU to the NAV position. (the OFF light goes off).
4. Procedure
Subtask 73-29-00-710-050-B ** ON A/C NOT FOR ALL
CAUTION: DO NOT OPERATE THE ENGINE IF THE FUEL INLET PRESSURE IS NOT POSITIVE. THE FUEL IS NECESSARY TO LUBRICATE THE ENGINE FUEL PUMP AND THE HMU AND THUS PREVENT DAMAGE.
A. Do this test:
F FADEC Test Engine Motoring ** ON A/C NOT FOR ALL
NOTE: This test is for the system 1. For the other system(s), use the indications between the parentheses.
ACTION
RESULT
1.Supply the engine with fuel.
NOTE: If the fuel line or fuel equipment has been disconnected/removed dowstream of the LP valve before the FADEC test with engine motoring, start the fuel pumps and open the LP valve.
A.On the HYD/FUEL panel 40VU:
  • Make sure that the engine 1(2) pump is serviceable (the OFF legend of the ENG1(2) PUMP pushbutton switch must be off).

B.Open the circuit breaker 1KC1(2) to open the LP valve.
  • On the upper ECAM display unit this message comes into view:
  • ENG 1(2) LP VALVE OPEN
  • The single chime operates.
  • The MASTER CAUT light comes on.
2.Push the line key adjacent to the FADEC 1A (2A) indication.
The ENGINE 1(2) MAIN MENU comes into view.
3.Push the line key adjacent to the FADEC TEST indication.
The FADEC TEST menu comes into view.
4.On the MCDU, push the line key adjacent to the PUSH BUTTON TO START THE TEST indication.
A new FADEC TEST menu comes into view
5.On the ENG panel 115VU, make sure that the ENG MODE CRANK/NORM/IGN/START selector switch is set to NORM.

6.On the ENG panel 115VU, set the ENG MASTER 1(2) control switch to ON and make sure that:
  • The engine operates (N2).
  • The oil pressure indication is positive.
The indication "WARNING TEST ACTIVE" comes into view. When the test is finish the FADEC TEST REPORT comes into view
7.Push the line key adjacent to RETURN
The page TEST COMPLETE comes into view
8.Set the ENG MASTER 1(2) lever to OFF.

9.Push the line key adjacent to the RETURN indication until the SYSTEM REPORT/TEST ENG MENU comes into view.
The ENGINE 1(2) MAIN MENU page comes into view
10.Do an ECU reset. To do this position the ENG MASTER control switch to ON then OFF.

11.Do the same procedure for channel B of the FADEC 1 (2).

12.On the MCDU, push the line select key adjacent to the RETURN indication until the CFDS menu page comes into view.
The MCDU menu comes into view.
13.Stop the MCDU.

14.Close the circuit breaker 1KC1(2) to close the LP valve.
On the upper ECAM display unit:
  • The ENG 1(2) LP VALVE OPEN message goes out of view.

The master CAUT light goes off.
5. Close-up
Subtask 73-29-00-860-052-A ** ON A/C NOT FOR ALL
A. Check Panels for Close-up.
   (1) On the FUEL part of the fuel control panel 40VU, release all the PUMPS pushbutton switches. On the pushbutton switches, the OFF legends come on.
   (2) On the maintenance panel 50VU, push the ENG1 (2) FADEC GND PWR pushbutton switch. On the pushbutton switch, the ON legend goes off.
   (3) Set the ADIRU to the OFF position.
   (4) On the overhead panel 40VU, make sure that the ENG PUMP pushbutton switches are set to on (FAULT and OFF lights are off).
   (5) Install the protective covers on the probes and sensors (Ref. AMM TASK 10-11-00-555-013).
Subtask 73-29-00-942-050-A ** ON A/C NOT FOR ALL
B. Disconnect the HP ground air supply unit, or stop the APU.
Subtask 73-29-00-862-050-A ** ON A/C NOT FOR ALL
C. De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.01 02:59:47 UTC