W DOC AIRBUS | AMM A320F

Visual Check of NEOL (Near End Of Life) Activation on Beacon Lights


TASK 33-48-00-200-802-A
Visual Check of NEOL (Near End Of Life) Activation on Beacon Lights


WARNING: DO NOT LOOK DIRECTLY AT THE LIGHT FLASH DURING THE TEST. SUPPLY A COVER, OR SHIELD, TO GIVE PROTECTION FROM THE LIGHT FLASH TO PERSONS IN THE TEST AREA.
ZONE: 140
ZONE: 244
1. Reason for the Job
Refer to the MPD TASK: 334800-01
VISUAL CHECK OF NEOL (NEAR END OF LIFE) ACTIVATION ON BEACON LIGHTS
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
STOPWATCH
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
140
CENTER WING
244
CENTER PASSENGER COMPT OVERHEAD COMPT
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 33-48-11-000-001-A
Removal of the Upper Beacon/Strobe Light from the Outside of the Fuselage
TASK 33-48-11-000-002-A
Removal of the Upper Beacon/Strobe Light from the Inside of the Fuselage
TASK 33-48-11-400-001-A
Installation of the Upper Beacon/Strobe Light from the Outside of the Fuselage
TASK 33-48-11-400-002-A
Installation of the Upper Beacon/Strobe Light from the Inside of the Fuselage
TASK 33-48-12-000-001-A
Removal of the Lower Beacon/Strobe Light from the Fuselage Outside
TASK 33-48-12-400-001-A
Installation of the Lower Beacon/Strobe Light from the Fuselage Outside
3. Job Set-up
Subtask 33-48-00-861-052-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 33-48-00-865-056-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
122VULIGHTING/EXT LT/BEACON/UPPER1LVU06
122VULIGHTING/EXT LT/BEACON/LOWER5LVU03
4. Procedure
Subtask 33-48-00-210-052-A ** ON A/C NOT FOR ALL
A. Visual Check of the NEOL Activation on the Beacon Lights
   (1) On the EXT LT section of overhead control and indicating panel 25VU, set BEACON switch 2LV to the ON position.
  • On the upper and lower fuselage, make sure that upper beacon light 7LV and lower beacon light 6LV come on.
   (2) Do a visual check of the NEOL activation on the beacon lights:
     (a) If these lights flash at a one-flash rate of 55 ± 5 flashes in one minute, measured with the STOPWATCH:
       1 The NEOL indicator light is off.
       2 The installed lights are serviceable.
     (b) If these lights flash at a two-flash rate of 55 ± flashes in one minute, measured with the STOPWATCH (two short flashes and a stop):
       1 The NEOL indicator light is on (the light is almost unserviceable).
       2 Replace the unserviceable beacon lights with the serviceable lights in the next 100 Flight Hours (FH):
   (3) On the EXT LT section of overhead control and indicating panel 25VU, set BEACON switch 2LV to the OFF position.
  • Make sure that upper beacon light 7LV and lower beacon light 6LV go off.
5. Close-up
Subtask 33-48-00-862-052-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.01 00:56:20 UTC