Visual Check of NEOL (Near End Of Life) Activation on Beacon Lights
TASK 33-48-00-200-802-A
Visual Check of NEOL (Near End Of Life) Activation on Beacon Lights
Refer to the MPD TASK: 334800-01
VISUAL CHECK OF NEOL (NEAR END OF LIFE) ACTIVATION ON BEACON LIGHTS
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 33-48-00-861-052-A ** ON A/C NOT FOR ALL
Subtask 33-48-00-210-052-A ** ON A/C NOT FOR ALL
Subtask 33-48-00-862-052-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:56:20 UTC
Visual Check of NEOL (Near End Of Life) Activation on Beacon Lights
WARNING:
DO NOT LOOK DIRECTLY AT THE LIGHT FLASH DURING THE TEST.
SUPPLY A COVER, OR SHIELD, TO GIVE PROTECTION FROM THE LIGHT FLASH TO PERSONS IN THE TEST AREA.
1. Reason for the JobRefer to the MPD TASK: 334800-01
VISUAL CHECK OF NEOL (NEAR END OF LIFE) ACTIVATION ON BEACON LIGHTS
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | STOPWATCH |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 140 | CENTER WING |
| 244 | CENTER PASSENGER COMPT OVERHEAD COMPT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 33-48-11-000-001-A | Removal of the Upper Beacon/Strobe Light from the Outside of the Fuselage |
| TASK 33-48-11-000-002-A | Removal of the Upper Beacon/Strobe Light from the Inside of the Fuselage |
| TASK 33-48-11-400-001-A | Installation of the Upper Beacon/Strobe Light from the Outside of the Fuselage |
| TASK 33-48-11-400-002-A | Installation of the Upper Beacon/Strobe Light from the Inside of the Fuselage |
| TASK 33-48-12-000-001-A | Removal of the Lower Beacon/Strobe Light from the Fuselage Outside |
| TASK 33-48-12-400-001-A | Installation of the Lower Beacon/Strobe Light from the Fuselage Outside |
Subtask 33-48-00-861-052-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 33-48-00-865-056-A ** ON A/C NOT FOR ALL (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
B. Make sure that this(these) circuit breaker(s) is(are) closed:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 122VU | LIGHTING/EXT LT/BEACON/UPPER | 1LV | U06 |
| 122VU | LIGHTING/EXT LT/BEACON/LOWER | 5LV | U03 |
Subtask 33-48-00-210-052-A ** ON A/C NOT FOR ALL
A. Visual Check of the NEOL Activation on the Beacon Lights
(1) On the EXT LT section of overhead control and indicating panel 25VU, set BEACON switch 2LV to the ON position.
(a) If these lights flash at a one-flash rate of 55 ± 5 flashes in one minute, measured with the STOPWATCH:
1 The NEOL indicator light is off.
2 The installed lights are serviceable.
(b) If these lights flash at a two-flash rate of 55 ± flashes in one minute, measured with the STOPWATCH (two short flashes and a stop):
1 The NEOL indicator light is on (the light is almost unserviceable).
2 Replace the unserviceable beacon lights with the serviceable lights in the next 100 Flight Hours (FH):
5. Close-up(1) On the EXT LT section of overhead control and indicating panel 25VU, set BEACON switch 2LV to the ON position.
- On the upper and lower fuselage, make sure that upper beacon light 7LV and lower beacon light 6LV come on.
(a) If these lights flash at a one-flash rate of 55 ± 5 flashes in one minute, measured with the STOPWATCH:
1 The NEOL indicator light is off.
2 The installed lights are serviceable.
(b) If these lights flash at a two-flash rate of 55 ± flashes in one minute, measured with the STOPWATCH (two short flashes and a stop):
1 The NEOL indicator light is on (the light is almost unserviceable).
2 Replace the unserviceable beacon lights with the serviceable lights in the next 100 Flight Hours (FH):
- For upper beacon light 7LV (Ref. AMM TASK 33-48-11-000-001) or (Ref. AMM TASK 33-48-11-000-002) and (Ref. AMM TASK 33-48-11-400-001) or (Ref. AMM TASK 33-48-11-400-002).
- For lower beacon light 6LV (Ref. AMM TASK 33-48-12-000-001) and (Ref. AMM TASK 33-48-12-400-001).
- Make sure that upper beacon light 7LV and lower beacon light 6LV go off.
Subtask 33-48-00-862-052-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
NEOL (Near End Of Life) Activation on Beacon Lights