Removal of the Upper Beacon/Strobe Light from the Inside of the Fuselage
TASK 33-48-11-000-002-A
Removal of the Upper Beacon/Strobe Light from the Inside of the Fuselage
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 33-48-11-860-050-A ** ON A/C NOT FOR ALL
Subtask 33-48-11-020-052-B ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 12:34:01 UTC
Removal of the Upper Beacon/Strobe Light from the Inside of the Fuselage
WARNING:
ISOLATE THE ELECTRICAL CIRCUITS FROM THE RELATED EQUIPMENT AND THE ENVIRONMENT.
NOTE: You can also remove the upper beacon/strobe light from the outside of the fuselage (Ref. TASK 33-48-11-000-001).
FIN: 7LV
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | 1 | STEPLADDER 1.5 M (5 FT) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 241CC |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 25-23-41-000-001-A | Removal of the Ceiling Panels |
Subtask 33-48-11-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that switch 2LV BEACON ON-OFF on the overhead panel 25VU is in the OFF position.
(2) Make sure that switch 4WL EMER EXIT LT OFF-ARM-ON on the overhead panel 25VU is in the OFF position.
(3) Make sure that the pushbutton EMERG LIGHT on Forward Attendant Panel (FAP) 120RH is in the released position.
Subtask 33-48-11-860-050-B ** ON A/C NOT FOR ALL (1) Make sure that switch 2LV BEACON ON-OFF on the overhead panel 25VU is in the OFF position.
(2) Make sure that switch 4WL EMER EXIT LT OFF-ARM-ON on the overhead panel 25VU is in the OFF position.
(3) Make sure that the pushbutton EMERG LIGHT on Forward Attendant Panel (FAP) 120RH is in the released position.
A. Aircraft Maintenance Configuration
(1) Make sure that the switch 2LV BEACON ON-OFF on the overhead panel 25VU is in the OFF position.
(2) Make sure that the switch 4WL EMER EXIT LT OFF-ARM-ON on the overhead panel 25VU is in the OFF position.
(3) Make sure that the EMER button on the Flight Attendant Panel (FAP) 120RH is OFF.
Subtask 33-48-11-865-051-A (1) Make sure that the switch 2LV BEACON ON-OFF on the overhead panel 25VU is in the OFF position.
(2) Make sure that the switch 4WL EMER EXIT LT OFF-ARM-ON on the overhead panel 25VU is in the OFF position.
(3) Make sure that the EMER button on the Flight Attendant Panel (FAP) 120RH is OFF.
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 33-48-11-010-053-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | LIGHTING/EXT LT/BEACON/UPPER | 1LV | U06 |
C. Get Access
(1) Put the STEPLADDER 1.5 M (5 FT) in position.
(2) Remove center ceiling panel 241CC to get access to the upper beacon/strobe light (Ref. AMM TASK 25-23-41-000-001).
4. Procedure(1) Put the STEPLADDER 1.5 M (5 FT) in position.
(2) Remove center ceiling panel 241CC to get access to the upper beacon/strobe light (Ref. AMM TASK 25-23-41-000-001).
Subtask 33-48-11-020-052-B ** ON A/C NOT FOR ALL
A. Removal of Upper Beacon/Strobe Light 7LV
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Loosen the screw (9) from the clamp (10).
(4) Remove the clamp (10).
(5) Lower the flange (7) with the O-ring (6).
(6) Remove the screws (4) from the LED module (5).
(7) Remove the LED module (5) from the flange (7).
Subtask 33-48-11-020-052-C ** ON A/C NOT FOR ALL CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
(1) Disconnect the electrical connector (8) from the LED module (5). (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Loosen the screw (9) from the clamp (10).
(4) Remove the clamp (10).
(5) Lower the flange (7) with the O-ring (6).
(6) Remove the screws (4) from the LED module (5).
(7) Remove the LED module (5) from the flange (7).
A. Removal of Upper Beacon/Strobe Light 7LV
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Loosen the screw (7) and remove the V-clamp (6) from the flange (3).
(4) Disengage the pin (13) of the light assembly (2) from the bung (10).
(5) Lower the moveable part of the flange (3) with the O-ring (4).
(6) Remove the screws (5) from the light assembly (2).
(7) Remove the light assembly (2) with the seal (12) from the moveable part of the flange (3).
CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
(1) Disconnect the electrical connector (1) from the light assembly (2). (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Loosen the screw (7) and remove the V-clamp (6) from the flange (3).
(4) Disengage the pin (13) of the light assembly (2) from the bung (10).
(5) Lower the moveable part of the flange (3) with the O-ring (4).
(6) Remove the screws (5) from the light assembly (2).
(7) Remove the light assembly (2) with the seal (12) from the moveable part of the flange (3).
Upper Beacon/Strobe Light 7LV