Operational Test of the Wireless Ground Link-Quick Access Recorder (WGL-QAR)
TASK 31-33-00-710-021-A
Operational Test of the Wireless Ground Link-Quick Access Recorder (WGL-QAR)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 31-33-00-861-071-C ** ON A/C NOT FOR ALL
Subtask 31-33-00-710-093-C ** ON A/C NOT FOR ALL
Subtask 31-33-00-410-076-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 08:31:12 UTC
Operational Test of the Wireless Ground Link-Quick Access Recorder (WGL-QAR)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 120 | AVIONICS COMPARTMENT |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 31-32-00-860-008-A | Procedure to Get Access to the SYSTEM REPORT/TEST/INST Page |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 31-60-00-860-002-A | EIS Stop Procedure |
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
| TASK 31-33-00-00 | DIGITAL FLIGHT DATA RECORDING SYSTEM (DFDRS) - INTERCONNECTION - DESCRIPTION AND OPERATION |
Subtask 31-33-00-861-071-C ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the aircraft is in Ground configuration (the landing gear is compressed and all engines are stopped).
(2) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(3) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
(4) Energize the CFDS (Ref. AMM TASK 31-32-00-860-008).
(5) On overhead maintenance panel 50VU, push the ENG FADEC GND PWR 1 pushbutton switch (the white ON legend comes on).
(6) On overhead maintenance panel 50VU, push the ENG FADEC GND PWR 2 pushbutton switch (the white ON legend comes on).
Subtask 31-33-00-010-077-A ** ON A/C NOT FOR ALL (1) Make sure that the aircraft is in Ground configuration (the landing gear is compressed and all engines are stopped).
(2) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(3) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
(4) Energize the CFDS (Ref. AMM TASK 31-32-00-860-008).
(5) On overhead maintenance panel 50VU, push the ENG FADEC GND PWR 1 pushbutton switch (the white ON legend comes on).
(6) On overhead maintenance panel 50VU, push the ENG FADEC GND PWR 2 pushbutton switch (the white ON legend comes on).
B. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below access door 824.
(2) Open access door 824 (Ref. AMM TASK 52-41-00-010-002).
(3) For the location of the WGL-QAR, refer to paragraph Component Location (Ref. AMM D/O 31-33-00-00).
Subtask 31-33-00-865-088-A ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below access door 824.
(2) Open access door 824 (Ref. AMM TASK 52-41-00-010-002).
(3) For the location of the WGL-QAR, refer to paragraph Component Location (Ref. AMM D/O 31-33-00-00).
C. Make sure that this(these) circuit breaker(s) is(are) closed:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | ENGINE/2/FADEC A/AND EIU 2 | 2KS2 | A05 |
| 49VU | ENGINE/1/FADEC A/AND EIU 1 | 2KS1 | A04 |
| 49VU | AUTO FLT/MCDU/1 | 11CA1 | B01 |
| 121VU | CFDS/CFDIU/SPLY | 2TW | J18 |
| 121VU | CFDS/CFDIU/BACK/UP | 8TW | J17 |
| 121VU | RCDR/ACCLRM | 9TU | K18 |
| 121VU | AIDS & RCDR/QAR | 14TU | K17 |
| 121VU | RCDR/DFDR | 7TU | K16 |
| 121VU | AIDS & RCDR/FDIMU | 5TV | K15 |
| 121VU | AUTO FLT/MCDU/2 | 11CA2 | N20 |
| 121VU | ENGINE/ENG2/FADEC B | 4KS2 | Q40 |
| 121VU | ENGINE/ENG1/FADEC B/AND EIU 1 | 4KS1 | R41 |
Subtask 31-33-00-710-093-C ** ON A/C NOT FOR ALL
A. Test of the Wireless Ground Link (WGL)-Quick Access Recorder (QAR)
Subtask 31-33-00-865-092-A ** ON A/C NOT FOR ALL | ACTION | RESULT |
|---|---|
| 1.On the WGL-QAR: |
|
|
|
| | On the WGL-QAR display:
|
| 2.In the cockpit, on overhead control panel 21VU: | In the cockpit, on overhead control panel 21VU: |
|
|
| | On the WGL-QAR Display: |
| |
|
| In the cockpit, on overhead control panel 21VU: | In the cockpit, on overhead control panel 21VU: |
|
|
| | On the WGL-QAR Display: |
| |
|
| 3.On the WGL-QAR Display: | On the WGL-QAR Display: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NOTE: The recording speed must agree with the SSFDR data rate. |
|
|
|
|
|
|
|
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 31-33-00-918-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | RCDR/ACCLRM | 9TU | K18 |
C. Wait response
(1) Wait for 5 seconds.
Subtask 31-33-00-865-091-A ** ON A/C NOT FOR ALL (1) Wait for 5 seconds.
D. Close this(these) circuit breaker(s):
5. Close-up| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | RCDR/ACCLRM | 9TU | K18 |
Subtask 31-33-00-410-076-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Close access door 824 (Ref. AMM TASK 52-41-00-410-002).
(2) Remove the access platform(s).
Subtask 31-33-00-862-071-C ** ON A/C NOT FOR ALL (1) Close access door 824 (Ref. AMM TASK 52-41-00-410-002).
(2) Remove the access platform(s).
B. Put the aircraft back to its initial configuration.
(1) De-energize the CFDS (Ref. AMM TASK 31-32-00-860-008).
(2) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
(3) On overhead maintenance panel 50VU, push the ENG FADEC GND PWR 1 pushbutton switch (the white ON legend goes off).
(4) On overhead maintenance panel 50VU, push the ENG FADEC GND PWR 2 pushbutton switch (the white ON legend goes off).
(5) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(1) De-energize the CFDS (Ref. AMM TASK 31-32-00-860-008).
(2) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
(3) On overhead maintenance panel 50VU, push the ENG FADEC GND PWR 1 pushbutton switch (the white ON legend goes off).
(4) On overhead maintenance panel 50VU, push the ENG FADEC GND PWR 2 pushbutton switch (the white ON legend goes off).
(5) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).