W DOC AIRBUS | AMM A320F

Reactivation of the Spoiler Servo-Control


TASK 27-64-00-440-001-A
Reactivation of the Spoiler Servo-Control


ZONE: 580
ZONE: 680
FIN: 31CE1
FIN: 31CE10
FIN: 31CE2
FIN: 31CE3
FIN: 31CE4
FIN: 31CE5
FIN: 31CE6
FIN: 31CE7
FIN: 31CE8
FIN: 31CE9
1. Reason for the Job
MMEL 27-64-01A
SPOILER 5
MMEL 27-64-02A
SPOILER 1 OR 3
MMEL 27-64-03A
SPOILER 2 OR 4
MMEL 27-64-05A
SPOILERS 3 AND 4
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
TOMMY BAR DIA 4 MM (0,157 IN) - METALLIC
No specific
AR
WARNING NOTICE(S)
98D27603002000
1
KEY-SPOILER MAINTENANCE
OR
OR
98D27603002001
1
KEY-SPOILER MAINTENANCE
98D27903500000
2
PIN-SIDE STICK LOCKING
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
580
LEFT WING FLAPS AND SPOILERS
680
RIGHT WING FLAPS AND SPOILERS
FOR [31CE1] (SERVO CTL-SPLR1, L G)
573BB
FOR [31CE10] (SERVO CTL-SPLR5, R G)
675GB
FOR [31CE2] (SERVO CTL-SPLR1, R G)
673BB
FOR [31CE3] (SERVO CTL-SPLR2, L Y)
575BB
FOR [31CE4] (SERVO CTL-SPLR2, R Y)
675BB
FOR [31CE5] (SERVO CTL-SPLR3, L B)
575DB
FOR [31CE6] (SERVO CTL-SPLR3, R B)
675DB
FOR [31CE7] (SERVO CTL-SPLR4, L Y)
575EB
FOR [31CE8] (SERVO CTL-SPLR4, R Y)
675EB
FOR [31CE9] (SERVO CTL-SPLR5, L G)
575GB
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 27-50-00-866-008-A
Extension of the Flaps on the Ground
TASK 27-50-00-866-008-A-01
Extension of the Flaps/Slats on the Ground
TASK 27-50-00-866-009-A
Retraction of the Flaps on the Ground
TASK 27-50-00-866-009-A-01
Retraction of the Flaps/Slats on the Ground
TASK 27-64-00-710-001-A
Operational Test of the Spoiler Hydraulic Actuation
TASK 29-10-00-864-003-A
Depressurize the Blue Hydraulic System
TASK 29-23-00-864-001-A
Depressurize the Green and Yellow Hydraulic Systems after Operation of the PTU
TASK 29-24-00-864-001-A
Depressurize the Yellow Hydraulic System
FOR [31CE1] (SERVO CTL-SPLR1, L G)
TASK 57-51-37-000-002-A
Removal of the Access Panels 571AB(671AB), 573AB(673AB), 573BB(673BB), 573CB(673CB), 573EB(673EB)
TASK 57-51-37-400-002-A
Installation of the Access Panels 571AB(671AB), 573AB(673AB), 573BB(673BB), 573CB(673CB), 573EB(673EB)
FOR [31CE10] (SERVO CTL-SPLR5, R G)
TASK 57-51-37-000-004-A
Removal of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB)
TASK 57-51-37-400-004-A
Installation of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB)
FOR [31CE2] (SERVO CTL-SPLR1, R G)
TASK 57-51-37-000-002-A
Removal of the Access Panels 571AB(671AB), 573AB(673AB), 573BB(673BB), 573CB(673CB), 573EB(673EB)
TASK 57-51-37-400-002-A
Installation of the Access Panels 571AB(671AB), 573AB(673AB), 573BB(673BB), 573CB(673CB), 573EB(673EB)
FOR [31CE3] (SERVO CTL-SPLR2, L Y)
TASK 57-51-37-000-004-A
Removal of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB)
TASK 57-51-37-400-004-A
Installation of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB)
FOR [31CE4] (SERVO CTL-SPLR2, R Y)
TASK 57-51-37-000-004-A
Removal of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB)
TASK 57-51-37-400-004-A
Installation of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB)
FOR [31CE5] (SERVO CTL-SPLR3, L B)
TASK 57-51-37-000-004-A
Removal of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB)
TASK 57-51-37-400-004-A
Installation of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB)
FOR [31CE6] (SERVO CTL-SPLR3, R B)
TASK 57-51-37-000-004-A
Removal of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB)
TASK 57-51-37-400-004-A
Installation of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB)
FOR [31CE7] (SERVO CTL-SPLR4, L Y)
TASK 57-51-37-000-004-A
Removal of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB)
TASK 57-51-37-400-004-A
Installation of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB)
FOR [31CE8] (SERVO CTL-SPLR4, R Y)
TASK 57-51-37-000-004-A
Removal of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB)
TASK 57-51-37-400-004-A
Installation of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB)
FOR [31CE9] (SERVO CTL-SPLR5, L G)
TASK 57-51-37-000-004-A
Removal of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB)
TASK 57-51-37-400-004-A
Installation of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB)
3. Job Set-up
Subtask 27-64-00-860-058-A
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
   (2) Extend the flaps (Ref. AMM TASK 27-50-00-866-008).
   (3) On the overhead panel, on FLT CTL panel 23VU, release the SEC 1 pushbutton switch (the OFF legend comes on).
   (4) On the overhead panel, on FLT CTL panel 24VU, release the SEC 2 and SEC 3 pushbutton switches (the OFF legends come on).
   (5) Depressurize the hydraulic system related to the spoiler that you must reactivate:
     (a) For spoiler 1 or 5, depressurize the Green hydraulic system (Ref. AMM TASK 29-23-00-864-001).
     (b) For spoiler 2 or 4, depressurize the Yellow hydraulic system (Ref. AMM TASK 29-24-00-864-001).
     (c) For spoiler 3, depressurize the Blue hydraulic system (Ref. AMM TASK 29-10-00-864-003).
Subtask 27-64-00-941-064-A
B. Safety Precautions
   (1) On the CAPT and F/O side-stick assemblies:
  • Put the 98D27903500000 PIN-SIDE STICK LOCKING in position.
  • Put the WARNING NOTICE(S) in position to tell persons not to touch them.
Subtask 27-64-00-010-064-B
C. Get Access
   (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position in:
     (a) Zone 580 for the left spoilers
     (b) Zone 680 for the right spoilers.
   (2) Open the applicable access panels:
     (a) FOR [31CE1] (SERVO CTL-SPLR1, L G)
Access panel 573BB (Ref. AMM TASK 57-51-37-000-002)
     (b) FOR [31CE2] (SERVO CTL-SPLR1, R G)
Access panel 673BB (Ref. AMM TASK 57-51-37-000-002)
     (c) FOR [31CE3] (SERVO CTL-SPLR2, L Y)
Access panel 575BB (Ref. AMM TASK 57-51-37-000-004)
     (d) FOR [31CE4] (SERVO CTL-SPLR2, R Y)
Access panel 675BB (Ref. AMM TASK 57-51-37-000-004)
     (e) FOR [31CE5] (SERVO CTL-SPLR3, L B)
Access panel 575DB (Ref. AMM TASK 57-51-37-000-004)
     (f) FOR [31CE6] (SERVO CTL-SPLR3, R B)
Access panel 675DB (Ref. AMM TASK 57-51-37-000-004)
     (g) FOR [31CE7] (SERVO CTL-SPLR4, L Y)
Access panel 575EB (Ref. AMM TASK 57-51-37-000-004)
     (h) FOR [31CE8] (SERVO CTL-SPLR4, R Y)
Access panel 675EB (Ref. AMM TASK 57-51-37-000-004)
     (i) FOR [31CE9] (SERVO CTL-SPLR5, L G)
Access panel 575GB (Ref. AMM TASK 57-51-37-000-004)
     (j) FOR [31CE10] (SERVO CTL-SPLR5, R G)
Access panel 675GB (Ref. AMM TASK 57-51-37-000-004).
4. Procedure
Subtask 27-64-00-440-050-B
A. Reactivation of the Spoiler Servo-Control
   (1) If there is no plate with the 'O' and 'M' indications on the maintenance device (PRE GOODRICH VSB 31077-27-15):
     (a) Put the servo-control in the Maintenance position:
CAUTION: DO NOT APPLY A HIGH TORQUE LOAD ON THE KEY SPOILER MAINTENANCE TOOL WHEN YOU SET THE SERVOCONTROL TO OPERATIONAL MODE OR MAINTENANCE MODE. IF YOU APPLY A HIGH TORQUE LOAD, IT CAN CAUSE DAMAGE TO THE TOOL AND/OR TO THE SERVOCONTROL.
       1 Install the 98D27603002000 KEY-SPOILER MAINTENANCE98D27603002001 KEY-SPOILER MAINTENANCE (3) and turn it a quarter turn counterclockwise.
NOTE: The necessary torque to operate the maintenance device is 0.350 m.daN (30.97 lbf.in). If 0.350 m.daN (30.97 lbf.in) is not sufficient to turn the KEY-SPOILER MAINTENANCE, it is possible that the maintenance device is damaged. To prevent more damage to the maintenance device, remove the spoiler servo-control and send it back to the supplier for analysis.
         a If you cannot turn the spoiler maintenance key, use the TOMMY BAR DIA 4 MM (0,157 IN) - METALLIC.
     (b) Remove and discard the tie-wraps.
     (c) Remove the CAP - BLANKING from the receptacle (1) and the connector (2).
     (d) Connect the connector (2) to the receptacle (1) of the servo-control.
     (e) Make sure that the spoiler is in the fully retracted position.
     (f) Put the servo-control in the Operation position:
CAUTION: DO NOT APPLY A HIGH TORQUE LOAD ON THE KEY SPOILER MAINTENANCE TOOL WHEN YOU SET THE SERVOCONTROL TO OPERATIONAL MODE OR MAINTENANCE MODE. IF YOU APPLY A HIGH TORQUE LOAD, IT CAN CAUSE DAMAGE TO THE TOOL AND/OR TO THE SERVOCONTROL.
       1 Turn the 98D27603002000 KEY-SPOILER MAINTENANCE98D27603002001 KEY-SPOILER MAINTENANCE (3) a quarter turn clockwise and remove it.
NOTE: The necessary torque to operate the maintenance device is 0.350 m.daN (30.97 lbf.in). If 0.350 m.daN (30.97 lbf.in) is not sufficient to turn the KEY-SPOILER MAINTENANCE, it is possible that the maintenance device is damaged. To prevent more damage to the maintenance device, remove the spoiler servo-control and send it back to the supplier for analysis.
         a If you cannot turn the spoiler maintenance key, use the TOMMY BAR DIA 4 MM (0,157 IN) - METALLIC.
     (g) Make sure that the work area is clean and clear of tools and other items.
     (h) Make sure that you cannot extend the spoiler:
CAUTION: MAKE SURE THAT NO SPOILER MAINTENANCE KEY STAYS ENGAGED IN THE MAINTENANCE DEVICE HOUSING. AERODYNAMIC FORCES WILL CAUSE UNWANTED MOVEMENT OF THE SPOILER IF THE MAINTENANCE KEY STAYS IN ITS HOUSING.
       1 Gradually apply a manual force on the spoiler surface trailing-edge.
   (2) If there is a plate with the 'O' and 'M' indications on the maintenance device (POST GOODRICH VSB 31077-27-15):
     (a) Put the servo-control in the Maintenance position:
CAUTION: DO NOT APPLY A HIGH TORQUE LOAD ON THE KEY SPOILER MAINTENANCE TOOL WHEN YOU SET THE SERVOCONTROL TO OPERATIONAL MODE OR MAINTENANCE MODE. IF YOU APPLY A HIGH TORQUE LOAD, IT CAN CAUSE DAMAGE TO THE TOOL AND/OR TO THE SERVOCONTROL.
       1 Install the 98D27603002000 KEY-SPOILER MAINTENANCE98D27603002001 KEY-SPOILER MAINTENANCE (3) and turn it a quarter turn counterclockwise to the 'M' position (Maintenance).
NOTE: The necessary torque to operate the maintenance device is 0.350 m.daN (30.97 lbf.in). If 0.350 m.daN (30.97 lbf.in) is not sufficient to turn the KEY-SPOILER MAINTENANCE, it is possible that the maintenance device is damaged. To prevent more damage to the maintenance device, remove the spoiler servo-control and send it back to the supplier for analysis.
         a If you cannot turn the spoiler maintenance key, use the TOMMY BAR DIA 4 MM (0,157 IN) - METALLIC.
     (b) Remove and discard the tie-wraps.
     (c) Remove the CAP - BLANKING from the receptacle (1) and the connector (2).
     (d) Connect the connector (2) to the receptacle (1) of the servo-control.
     (e) Make sure that the spoiler is in the fully retracted position.
     (f) Put the servo-control in the Operation position:
CAUTION: DO NOT APPLY A HIGH TORQUE LOAD ON THE KEY SPOILER MAINTENANCE TOOL WHEN YOU SET THE SERVOCONTROL TO OPERATIONAL MODE OR MAINTENANCE MODE. IF YOU APPLY A HIGH TORQUE LOAD, IT CAN CAUSE DAMAGE TO THE TOOL AND/OR TO THE SERVOCONTROL.
       1 Turn the 98D27603002000 KEY-SPOILER MAINTENANCE98D27603002001 KEY-SPOILER MAINTENANCE (3) a quarter turn clockwise to the 'O' position (Operation) and remove it.
NOTE: The necessary torque to operate the maintenance device is 0.350 m.daN (30.97 lbf.in). If 0.350 m.daN (30.97 lbf.in) is not sufficient to turn the KEY-SPOILER MAINTENANCE, it is possible that the maintenance device is damaged. To prevent more damage to the maintenance device, remove the spoiler servo-control and send it back to the supplier for analysis.
         a If you cannot turn the spoiler maintenance key, use the TOMMY BAR DIA 4 MM (0,157 IN) - METALLIC.
     (g) Make sure that the work area is clean and clear of tools and other items.
     (h) Make sure that you cannot extend the spoiler:
CAUTION: MAKE SURE THAT NO SPOILER MAINTENANCE KEY STAYS ENGAGED IN THE MAINTENANCE DEVICE HOUSING. AERODYNAMIC FORCES WILL CAUSE UNWANTED MOVEMENT OF THE SPOILER IF THE MAINTENANCE KEY STAYS IN ITS HOUSING.
CAUTION: MAKE SURE THAT THE STOP OF THE HEXAGONAL-HEAD CONTROL SWITCH IS AGAINST THE LETTER 'O' ON THE HOUSING. IF IT IS AGAINST THE LETTER 'M', AERODYNAMIC FORCES WILL CAUSE UNWANTED MOVEMENT OF THE SPOILER AND POSSIBLE DAMAGE TO EQUIPMENT.
       1 Gradually apply a manual force on the spoiler surface trailing-edge.
Subtask 27-64-00-410-069-A
B. Preparation of the Test
   (1) Remove the 98D27903500000 PIN-SIDE STICK LOCKING and the WARNING NOTICE(S) from each side stick assembly.
   (2) Retract the flaps (Ref. AMM TASK 27-50-00-866-009).
   (3) On the overhead panel, on FLT CTL panel 23VU, push the SEC 1 pushbutton switch (the OFF legend goes off).
   (4) On the overhead panel, on FLT CTL panel 24VU, push the SEC 2 and SEC 3 pushbutton switches (the OFF legends go off).
Subtask 27-64-00-710-053-A
C. Do an operational test of the reactivated spoilers (Ref. AMM TASK 27-64-00-710-001).
Subtask 27-64-00-810-050-A
D. Do the troubleshooting on the defective spoiler servo-control that you deactivated with the Fault Symptom as entry into the Trouble Shooting Manual (TSM).
5. Close-up
Subtask 27-64-00-410-068-B
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the applicable access panels:
     (a) FOR [31CE1] (SERVO CTL-SPLR1, L G)
Access panel 573BB (Ref. AMM TASK 57-51-37-400-002)
     (b) FOR [31CE2] (SERVO CTL-SPLR1, R G)
Access panel 673BB (Ref. AMM TASK 57-51-37-400-002)
     (c) FOR [31CE3] (SERVO CTL-SPLR2, L Y)
Access panel 575BB (Ref. AMM TASK 57-51-37-400-004)
     (d) FOR [31CE4] (SERVO CTL-SPLR2, R Y)
Access panel 675BB (Ref. AMM TASK 57-51-37-400-004)
     (e) FOR [31CE5] (SERVO CTL-SPLR3, L B)
Access panel 575DB (Ref. AMM TASK 57-51-37-400-004)
     (f) FOR [31CE6] (SERVO CTL-SPLR3, R B)
Access panel 675DB (Ref. AMM TASK 57-51-37-400-004)
     (g) FOR [31CE7] (SERVO CTL-SPLR4, L Y)
Access panel 575EB (Ref. AMM TASK 57-51-37-400-004)
     (h) FOR [31CE8] (SERVO CTL-SPLR4, R Y)
Access panel 675EB (Ref. AMM TASK 57-51-37-400-004)
     (i) FOR [31CE9] (SERVO CTL-SPLR5, L G)
Access panel 575GB (Ref. AMM TASK 57-51-37-400-004)
     (j) FOR [31CE10] (SERVO CTL-SPLR5, R G)
Access panel 675GB (Ref. AMM TASK 57-51-37-400-004).
   (3) Remove the access platform(s).
Subtask 27-64-00-860-059-A
B. Put the aircraft back to its initial configuration.
   (1) De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.03.31 23:55:18 UTC