W DOC AIRBUS | AMM A320F

Removal of the Access Panels 571AB(671AB), 573AB(673AB), 573BB(673BB), 573CB(673CB), 573EB(673EB)


TASK 57-51-37-000-002-A
Removal of the Access Panels 571AB(671AB), 573AB(673AB), 573BB(673BB), 573CB(673CB), 573EB(673EB)


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
CAUTION: BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING EDGE:
  • DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.
  • DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.
  • MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. INCORRECT INSTALLATION CAN CAUSE DAMAGE.
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 4M (13 FT)
No specific
AR
SAFETY BARRIER(S)
No specific
AR
WARNING NOTICE(S)
98D27803500001
1
LOCKING TOOL ZERO POS
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 27-50-00-866-009-A
Retraction of the Flaps on the Ground
TASK 27-50-00-866-009-A-01
Retraction of the Flaps/Slats on the Ground
3. Job Set-up
Subtask 57-51-37-941-052-A
A. Safety Precautions
As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
   (1) Make sure that the flaps are fully retracted (Ref. AMM TASK 27-50-00-866-009).
   (2) Install the 98D27803500001 LOCKING TOOL ZERO POS on the flap/slat control lever.
   (3) Put the WARNING NOTICE(S) in the cockpit to tell persons not to operate the flaps.
Subtask 57-51-37-010-052-A
B. Get Access
   (1) Put the ACCESS PLATFORM 4M (13 FT) below the applicable access panel, zone 573(673).
4. Procedure
Subtask 57-51-37-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Access Panels
   (1) For the access panel 573AB(673AB) (6):
     (a) Release the nine camloc fasteners (5) then remove the access panel (6).
   (2) For the access panel 573BB(673BB) (4):
     (a) Release the eight camloc fasteners (3) then remove the access panel (4).
   (3) For the access panel 573CB(673CB) (2):
     (a) Release the five camloc fasteners (1) then remove the access panel (2).
   (4) For the access panel 573EB(673EB) (11):
NOTE: Record the position of the pipes for the installation procedure.
     (a) Remove and discard the strip-protective (10).
     (b) Remove the bolts (9), the plate clamp (8) and the plate (7).
     (c) Remove the bolts (12) and the access panel (11).
   (5) For the access panel 571AB(671AB) (15):
     (a) Remove the nuts (13), the bolts (16) from the access panel (15).
     (b) Remove the nut plate (14) and the access panel (15).
Subtask 57-51-37-020-050-B ** ON A/C NOT FOR ALL
A. Removal of the Access Panels
   (1) For the access panel 573AB(673AB) (6):
     (a) Release the nine camloc fasteners (5) then remove the access panel (6).
   (2) For the access panel 573BB(673BB) (4):
     (a) Release the eight camloc fasteners (3) then remove the access panel (4).
   (3) For the access panel 573CB(673CB) (2):
     (a) Release the five camloc fasteners (1) then remove the access panel (2).
   (4) For the access panel 573EB(673EB) (8):
NOTE: Record the position of the pipes for the installation procedure.
     (a) Remove the bolts (7) from the access panel (8).
     (b) Remove the access panel (8).
   (5) For the access panel 571AB(671AB)(11):
     (a) Remove the nuts (9), the bolts (12) from the access panel (11).
     (b) Remove the nut plate (10) and the access panel (11).
[Rev.10 from 2021] 2026.04.01 02:15:27 UTC