W DOC AIRBUS | AMM A320F

Adjustment of the Proximity Switches of the Locking Handle of the Cargo Compartment Doors


TASK 52-71-00-820-004-A
Adjustment of the Proximity Switches of the Locking Handle of the Cargo Compartment Doors


ZONE: 825
ZONE: 826
FIN: 28WV
FIN: 34WV
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE
No specific
1
GAGE - FEELER
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
FOR [34WV] (PROX SW-HANDLE, AFT CARGO COMPT DOOR)
No specific
1
GAGE - FEELER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
825
FORWARD CARGO COMPARTMENT DOOR
826
AFT CARGO COMPARTMENT DOOR
825, 826
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
TASK 52-30-00-860-002-A
Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
TASK 52-31-13-000-001-A
Removal of the Lining and the Insulation
TASK 52-31-13-400-001-A
Installation of the Lining and the Insulation
TASK 52-31-14-000-801-A
Removal of the FWD Cargo-Compartment Door Access-Panel
TASK 52-31-14-400-801-A
Installation of the FWD Cargo-Compartment Door Access-Panel
TASK 52-32-14-000-801-A
Removal of the Aft Cargo-Compartment-Door Access-Panels
TASK 52-32-14-400-801-A
Installation of the Aft Cargo-Compartment-Door Access-Panels
TASK 52-71-00-710-001-A
Operational Test of the Door Warning System
TASK 06-41-52-00
DOORS - DESCRIPTION AND OPERATION
F Inner Access Panel ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 52-71-00-861-061-A
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 52-71-00-010-057-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position at applicable cargo compartment door 825 or 826.
   (2) Remove the applicable access panel (Ref. AMM TASK 52-31-14-000-801) or (Ref. AMM TASK 52-32-14-000-801).
NOTE: You can refer to AMM chapter 06 for the access panel details (Ref. AMM D/O 06-41-52-00).
Subtask 52-71-00-010-057-B ** ON A/C NOT FOR ALL
B. Get Access
   (1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position at applicable cargo compartment door 825 or 826.
   (2) Remove the applicable access panel (Ref. AMM TASK 52-31-14-000-801) or (Ref. AMM TASK 52-32-14-000-801).
NOTE: You can refer to AMM chapter 06 for the access panel details (Ref. AMM D/O 06-41-52-00).
   (3) Open the applicable cargo compartment door (Ref. AMM TASK 52-30-00-860-001).
   (4) If necessary, remove the lining and the insulation from the applicable cargo compartment door (Ref. AMM TASK 52-31-13-000-001).
   (5)
F Inner Access Panel ** ON A/C NOT FOR ALL
   (6) Close the applicable cargo compartment door (Ref. AMM TASK 52-30-00-860-002).
Subtask 52-71-00-865-054-A
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
122VUDOORS/CARGO1MJT12
4. Procedure
Subtask 52-71-00-820-055-B ** ON A/C NOT FOR ALL
A. Adjustment of the Proximity Switch
   (1) Make sure that the applicable cargo compartment door is correctly locked with the locking handle (4) in the recess of the handle flap (Ref. AMM TASK 52-30-00-860-002).
   (2) Measure clearance J2 between the target (1) and the proximity switch (2) with the GAGE - FEELER.
   (3) Make sure that clearance J2 is between 1.60 mm (0.0630 in.) and 2.00 mm (0.0787 in.).
   (4) If clearance J2 is not in the tolerance, adjust it as follows:
     (a) Open the cargo compartment door and safety it with the actuator safety locks (Ref. AMM TASK 52-30-00-860-001).
     (b) Do the adjustment of the target (1):
       1 Loosen the nuts (5).
       2 Adjust distance J1 between the locking handle (4) and the T-part of the target (1) to 3.2 mm (0.1 in.).
       3 Tighten the nuts (5).
     (c) Close the cargo compartment door (Ref. AMM TASK 52-30-00-860-002).
   (5) Do a check of clearance J2 again. For this, do steps (1) thru (3).
   (6) If clearance J2 is not in the tolerance, do step (4) again.
Subtask 52-71-00-820-055-D ** ON A/C NOT FOR ALL
A. Adjustment of the Proximity Switch
NOTE: Two persons are necessary to do the check.
   (1) Make sure that the applicable cargo compartment door is correctly locked with the locking handle (4) in the recess of the handle flap (Ref. AMM TASK 52-30-00-860-002).
   (2) FOR [34WV] (PROX SW-HANDLE, AFT CARGO COMPT DOOR)
Measure clearance J2 between the target (1) and the proximity switch (2):
     (a) Measure clearance J2 from the inner side of the door.
     (b) Bend as necessary the blades of the GAGE - FEELER to measure clearance J2.
   (3) Measure clearance J2 between the target (1) and the proximity switch (2) with the GAGE - FEELER.
   (4) Make sure that clearance J2 is between 1.60 mm (0.0630 in.) and 2.00 mm (0.0787 in.).
   (5) If clearance J2 is not in the tolerance, adjust it as follows:
     (a) Open the cargo compartment door and safety it with the actuator safety locks (Ref. AMM TASK 52-30-00-860-001).
     (b) Do the adjustment of the target (1):
       1 Loosen the nuts (5).
       2 FOR [28WV] (PROX SW-HANDLE, FWD CARGO COMPT DOOR)
Adjust distance J1 between the locking handle (4) and the T-part of the target (1) to 3.2 mm (0.1 in.).
       3 FOR [34WV] (PROX SW-HANDLE, AFT CARGO COMPT DOOR)
Adjust distance J1 between the locking handle (4) and the T-part of the target (1) to 4.0 mm (0.2 in.).
       4 Tighten the nuts (5).
     (c) Close the cargo compartment door (Ref. AMM TASK 52-30-00-860-002).
   (6) Do a check of clearance J2 again. For this, do steps (1) thru (4).
   (7) If clearance J2 is not in the tolerance, do step (5) again.
Subtask 52-71-00-710-060-A
B. Operational Test
   (1) Do the operational test of the door warning system related to the cargo compartment doors (Ref. AMM TASK 52-71-00-710-001).
5. Close-up
Subtask 52-71-00-410-059-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the applicable access panel (Ref. AMM TASK 52-31-14-400-801) or (Ref. AMM TASK 52-32-14-400-801).
NOTE: You can refer to AMM chapter 06 for the access panel details (Ref. AMM D/O 06-41-52-00).
   (3) Remove the access platform(s).
Subtask 52-71-00-410-059-B ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2)
F Inner Access Panel ** ON A/C NOT FOR ALL
   (3) If necessary, install the lining and the insulation on the applicable cargo compartment door (Ref. AMM TASK 52-31-13-400-001).
   (4) Remove the actuator safety locks and close the applicable cargo compartment door (Ref. AMM TASK 52-30-00-860-002).
   (5) Install the applicable access panel (Ref. AMM TASK 52-31-14-400-801) or (Ref. AMM TASK 52-32-14-400-801).
NOTE: You can refer to AMM chapter 06 for the access panel details (Ref. AMM D/O 06-41-52-00).
   (6) Remove the access platform(s).
Subtask 52-71-00-865-055-A
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
122VUDOORS/CARGO1MJT12
Subtask 52-71-00-862-054-A
C. De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.01 12:31:15 UTC