Installation of the Lining and the Insulation
TASK 52-31-13-400-001-A
Installation of the Lining and the Insulation
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 52-31-13-865-051-A
Subtask 52-31-13-420-050-D
Subtask 52-31-13-865-052-A
[Rev.10 from 2021]
2026.04.01 01:41:08 UTC
Installation of the Lining and the Insulation
CAUTION:
IMMEDIATELY AFTER YOU OPEN THE CARGO COMPARTMENT DOOR, RECORD ON THE WORK CARD ON THE DOOR, THE DATE AND TIME WHEN YOU OPENED IT. IF THE CARGO COMPARTMENT DOOR STAYS OPEN FOR 12 HOURS OR MORE, YOU MUST BLEED THE HYDRAULIC SYSTEM RELATED TO IT. IF YOU DO NOT OBEY THESE PRECAUTIONS, THE DOOR CAN CLOSE SUDDENLY WHEN YOU SET THE DOOR TO "CLOSE". THIS CAN CAUSE DAMAGE TO THE DOOR AND TO THE AIRCRAFT STRUCTURE.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-002-A | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 52-31-13-865-051-A
A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
Subtask 52-31-13-860-052-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/HYD POWER/Y | 3803GX | N30 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/HYD POWER/Y | 3803GX | N31 |
| ** ON A/C ALL | |||
| 122VU | DOORS/CARGO | 1MJ | T12 |
| 123VU | Y HYD/ELEC/PUMP | 3802GX | AB06 |
| 123VU | Y HYD/ELEC/ELEC PUMP/NORM | 3801GX | AB03 |
B. Aircraft Maintenance Configuration
(1) Make sure that the FWD and/or AFT cargo-compartment door(s) (referred to as cargo door(s)) are opened and the actuator safety locks are installed (Ref. AMM TASK 52-30-00-860-001).
(2) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below the opened cargo door.
4. Procedure(1) Make sure that the FWD and/or AFT cargo-compartment door(s) (referred to as cargo door(s)) are opened and the actuator safety locks are installed (Ref. AMM TASK 52-30-00-860-001).
(2) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below the opened cargo door.
Subtask 52-31-13-420-050-D
A. Installation of the Protective Lining
(1) Put the protective lining (3) with the self-adhesive insulation mat in position at the cargo door (1) and engage the VELCRO tapes.
(2) Attach the protective lining (3) with the quick-release fasteners (2) to the cargo door (1).
5. Close-up(1) Put the protective lining (3) with the self-adhesive insulation mat in position at the cargo door (1) and engage the VELCRO tapes.
(2) Attach the protective lining (3) with the quick-release fasteners (2) to the cargo door (1).
Subtask 52-31-13-865-052-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 52-31-13-410-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/HYD POWER/Y | 3803GX | N30 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/HYD POWER/Y | 3803GX | N31 |
| ** ON A/C ALL | |||
| 122VU | DOORS/CARGO | 1MJ | T12 |
| 123VU | Y HYD/ELEC/PUMP | 3802GX | AB06 |
| 123VU | Y HYD/ELEC/ELEC PUMP/NORM | 3801GX | AB03 |
B. Close Access
(1) Remove the actuator safety locks and close the FWD and/or AFT cargo-compartment door(s) (Ref. AMM TASK 52-30-00-860-002).
(2) Remove the access platform(s).
(1) Remove the actuator safety locks and close the FWD and/or AFT cargo-compartment door(s) (Ref. AMM TASK 52-30-00-860-002).
(2) Remove the access platform(s).
Lining and Insulation