Operational Test of the Door Warning System
TASK 52-71-00-710-001-A
Operational Test of the Door Warning System
Refer to the MPD TASK: 527100-01
OPERATIONAL CHECK OF DOOR WARNING SYSTEM
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 52-71-00-861-050-A Subtask 52-71-00-865-051-A
Subtask 52-71-00-710-050-B ** ON A/C NOT FOR ALL
Subtask 52-71-00-860-061-A
[Rev.10 from 2021]
2026.04.01 12:44:09 UTC
Operational Test of the Door Warning System
ZONE: 210
1. Reason for the JobRefer to the MPD TASK: 527100-01
OPERATIONAL CHECK OF DOOR WARNING SYSTEM
NOTE: This task is only applicable to these doors without mechanical and/or permanent blockage from the inner/outer part of the aircraft:
2. Job Set-up Information- The passenger/crew doors
- The emergency exit doors
- The avionics compartment doors.
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE |
| No specific | AR | WARNING NOTICE(S) |
| No specific | 1 | WRENCH - SPANNER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 31-60-00-860-002-A | EIS Stop Procedure |
| TASK 52-10-00-010-001-A | Opening of the Passenger/Crew Door |
| TASK 52-10-00-410-001-A | Closing of the Passenger/Crew Door |
| TASK 52-10-00-860-001-A | Special Precautions before Work on the Passenger/Crew Door |
| TASK 52-10-00-860-002-A | Special Precautions after Work on the Passenger/Crew Door |
| TASK 52-22-00-010-002-A | Opening of the Emergency Exit Doors from the Outside |
| TASK 52-22-00-410-002-A | Closing of the Emergency Exit Doors from the Outside |
| TASK 52-22-00-860-003-A | Special Precaution before Maintenance on the Door Damper and Emergency Operation Cylinder |
| TASK 52-22-00-860-004-A | Special Precaution after Maintenance on the Door Damper and Emergency Operation Cylinder |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-002-A | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 52-71-00-861-050-A Subtask 52-71-00-865-051-A
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
Subtask 52-71-00-869-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | LIGHTING/EMER LT/CABIN | 2WL | H06 |
| 49VU | LIGHTING/EMER LT/CABIN | 1WL | H05 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | LIGHTING/EMER LT/CABIN | 2WL | H04 |
| 49VU | LIGHTING/EMER LT/CABIN | 1WL | H03 |
| ** ON A/C ALL | |||
| 122VU | LIGHTING/CABIN/EMER/LT | 3WL | V07 |
C. Get Access
(1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position in front of the passenger/crew door at zone 831, 832, 841 or 842.
(2) Open the applicable passenger/crew door (Ref. AMM TASK 52-10-00-010-001).
(3) Obey the special precautions before you start the work on the door (Ref. AMM TASK 52-10-00-860-001).
(4) Disarm the escape slides of the four emergency exits doors (3):
(a) Open and remove the flaps (2) from the four emergency exits doors (3).
Subtask 52-71-00-869-050-B ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position in front of the passenger/crew door at zone 831, 832, 841 or 842.
(2) Open the applicable passenger/crew door (Ref. AMM TASK 52-10-00-010-001).
(3) Obey the special precautions before you start the work on the door (Ref. AMM TASK 52-10-00-860-001).
(4) Disarm the escape slides of the four emergency exits doors (3):
(a) Open and remove the flaps (2) from the four emergency exits doors (3).
NOTE: The two SLIDE ARMED indicator lights (4) come on.
(b) On the four emergency exits doors (3), use the applicable wrench to turn the head of the latch pin (1) a quarter turn counterclockwise to retract the latch pin (1). NOTE: The two SLIDE ARMED indicator lights (4) go off.
(c) Install and close the flaps (2) on the four emergency exits doors (3). C. Get Access
(1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position in front of the passenger/crew door at zone 831, 841, 832 or 842.
(2) Open the applicable passenger/crew door (Ref. AMM TASK 52-10-00-010-001).
(3) Obey the special precautions before you start the work on the door (Ref. AMM TASK 52-10-00-860-001).
(4) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in front of the applicable emergency exit door at zone 833, 834, 843 or 844.
(5) Open the applicable emergency exit door (Ref. AMM TASK 52-22-00-010-002).
(6) Obey the safety precautions before you start the work on the emergency exit door (Ref. AMM TASK 52-22-00-860-003).
(7) Close the doors from the inside.
Subtask 52-71-00-869-050-C ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position in front of the passenger/crew door at zone 831, 841, 832 or 842.
(2) Open the applicable passenger/crew door (Ref. AMM TASK 52-10-00-010-001).
(3) Obey the special precautions before you start the work on the door (Ref. AMM TASK 52-10-00-860-001).
(4) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in front of the applicable emergency exit door at zone 833, 834, 843 or 844.
(5) Open the applicable emergency exit door (Ref. AMM TASK 52-22-00-010-002).
(6) Obey the safety precautions before you start the work on the emergency exit door (Ref. AMM TASK 52-22-00-860-003).
(7) Close the doors from the inside.
C. Get Access
(1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position in front of the passenger/crew door at zone 831, 832, 841 or 842.
(2) Open the applicable passenger/crew door (Ref. AMM TASK 52-10-00-010-001).
(3) Obey the special precautions before you start the work on the door (Ref. AMM TASK 52-10-00-860-001).
(4) Disarm the escape slides of the two emergency exit doors (3):
(a) Open and remove the flaps (2) from the two emergency exit doors (3).
Subtask 52-71-00-869-050-G ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position in front of the passenger/crew door at zone 831, 832, 841 or 842.
(2) Open the applicable passenger/crew door (Ref. AMM TASK 52-10-00-010-001).
(3) Obey the special precautions before you start the work on the door (Ref. AMM TASK 52-10-00-860-001).
(4) Disarm the escape slides of the two emergency exit doors (3):
(a) Open and remove the flaps (2) from the two emergency exit doors (3).
NOTE: The two SLIDE ARMED indicator lights (4) come on.
(b) On the two emergency exit doors (3), use the applicable wrench to turn the head of the latch pin (1) a quarter turn counterclockwise to retract the latch pin (1). NOTE: The two SLIDE ARMED indicator lights (4) go off.
(c) Install and close the flaps (2) on the two emergency exits doors (3). C. Get Access
(1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position in front of the applicable passenger/crew door at zone 831 or 841 or 832 or 842.
(2) Open the applicable passenger/crew door (Ref. AMM TASK 52-10-00-010-001).
(3) Obey the special precautions before you start the work on the door (Ref. AMM TASK 52-10-00-860-001).
(4) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position in front of the applicable emergency exit door at zone 835 or 845.
(5) Open the applicable emergency exit door (Ref. AMM TASK 52-22-00-010-002).
(6) Obey the safety precautions before you start the work on the emergency exit door (Ref. AMM TASK 52-22-00-860-003).
(7) Close the doors from the inside.
Subtask 52-71-00-860-060-A ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position in front of the applicable passenger/crew door at zone 831 or 841 or 832 or 842.
(2) Open the applicable passenger/crew door (Ref. AMM TASK 52-10-00-010-001).
(3) Obey the special precautions before you start the work on the door (Ref. AMM TASK 52-10-00-860-001).
(4) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position in front of the applicable emergency exit door at zone 835 or 845.
(5) Open the applicable emergency exit door (Ref. AMM TASK 52-22-00-010-002).
(6) Obey the safety precautions before you start the work on the emergency exit door (Ref. AMM TASK 52-22-00-860-003).
(7) Close the doors from the inside.
D. Aircraft Maintenance Configuration
(2) Do the EIS start procedure (Ref. AMM TASK 31-60-00-860-001).
(3) On the ECAM control panel, push the DOOR key. On the lower ECAM Display Unit (DU), the "DOOR/OXY" page comes into view.
(4) Put the WARNING NOTICE(S) in position on the applicable door to tell persons not to open the door during the test procedure.
(5) Make sure that these doors are closed and locked:
Subtask 52-71-00-860-060-C ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE SLIDING WINDOW IS OPEN. THIS PREVENTS PRESSURIZATION OF THE AIRCRAFT WHEN THE AVIONICS VENTILATION SYSTEM OPERATES AND ALL THE DOORS ARE CLOSED.
(1) Make sure that all the doors are closed. (2) Do the EIS start procedure (Ref. AMM TASK 31-60-00-860-001).
(3) On the ECAM control panel, push the DOOR key. On the lower ECAM Display Unit (DU), the "DOOR/OXY" page comes into view.
(4) Put the WARNING NOTICE(S) in position on the applicable door to tell persons not to open the door during the test procedure.
(5) Make sure that these doors are closed and locked:
- The four avionics compartment access-doors
- The forward and aft cargo-compartment doors (Ref. AMM TASK 52-30-00-860-002)
- The four passenger/crew doors
- The bulk cargo-compartment door (if installed)
- The entrance stairs door (if installed)
- The emergency exit doors.
D. Aircraft Maintenance Configuration
(2) Do the EIS start procedure (Ref. AMM TASK 31-60-00-860-001).
(3) On the ECAM control panel, push the DOOR key. On the lower ECAM DU, the "DOOR/OXY" page comes into view.
(4) Put the WARNING NOTICE(S) in position on the applicable door to tell persons not to open the door during the test procedure.
(5) Make sure that these doors are closed and locked:
Subtask 52-71-00-865-050-A WARNING:
MAKE SURE THAT THE SLIDING WINDOW IS OPEN. THIS PREVENTS PRESSURIZATION OF THE AIRCRAFT WHEN THE AVIONICS VENTILATION SYSTEM OPERATES AND ALL THE DOORS ARE CLOSED.
(1) Make sure that all the doors are closed. (2) Do the EIS start procedure (Ref. AMM TASK 31-60-00-860-001).
(3) On the ECAM control panel, push the DOOR key. On the lower ECAM DU, the "DOOR/OXY" page comes into view.
(4) Put the WARNING NOTICE(S) in position on the applicable door to tell persons not to open the door during the test procedure.
(5) Make sure that these doors are closed and locked:
- The four avionics compartment access-doors
- The forward and aft cargo-compartment doors (Ref. AMM TASK 52-30-00-860-002)
- The four passenger/crew doors
- The bulk cargo-compartment door (if installed)
- The entrance stairs door (if installed)
- The two emergency exit doors
- The four overwing emergency-exit doors.
E. Make sure that this(these) circuit breaker(s) is(are) closed:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | L/G/LGCIU/SYS1/NORM | 1GA | C09 |
| 49VU | SDAC/1/SPLY | 3WV | F04 |
| 49VU | FWS/FWC1/SPLY | 3WW | F01 |
| 121VU | EIS/SLIDES/ARM AND WARN/FLT | 15WN | P11 |
| 121VU | EIS/SLIDES/ARM AND WARN/GND | 13WN | P10 |
| 121VU | EIS/SDAC1 AND 2/DOOR/DET/PAX | 48WV | P05 |
| 121VU | EIS/SDAC1 AND 2/DOOR/DET/AVNCS | 46WV | P02 |
| 121VU | HYDRAULIC/LGCIU/SYS2 | 2GA | Q35 |
| 121VU | HYDRAULIC/LGCIU/SYS1/GRND SPLY | 52GA | Q34 |
| 121VU | EIS/FWC2/SPLY | 2WW | Q07 |
| 121VU | EIS/SDAC/2/SPLY | 2WV | Q06 |
Subtask 52-71-00-710-050-B ** ON A/C NOT FOR ALL
A. Test of the Door Warning System
(Ref. AMM TASK 52-30-00-860-001) (Ref. AMM TASK 52-30-00-860-002)
Subtask 52-71-00-710-050-G ** ON A/C NOT FOR ALL (Ref. AMM TASK 52-30-00-860-001) (Ref. AMM TASK 52-30-00-860-002)
WARNING:
INSTALL A SAFETY BARRIER WHEN YOU OPEN A DOOR IF THE ACCESS PLATFORM IS NOT USED.
(1) Do the test that follows: | ACTION | RESULT |
|---|---|
| 1.On the ECAM control panel, push the DOOR key. | On the lower ECAM DU, on the "DOOR/OXY" page:
|
2.On circuit breaker panel 121VU:
| No change. |
3.On circuit breaker panel 121VU:
| No change. |
| 4.Open the four avionics compartment doors. | On the lower ECAM DU, on the "DOOR/OXY" page:
|
| 5.Open the two cargo compartment doors (Ref. AMM TASK 52-30-00-860-001). | On the lower ECAM DU, on the "DOOR/OXY" page:
|
| 6.Open the bulk cargo-compartment door. | On the lower ECAM DU, on the "DOOR/OXY" page:
|
| 7.Open the four passenger/crew doors and the four flaps that give access to the control handles of the emergency exit doors. | On the lower ECAM DU, on the "DOOR/OXY" page:
|
8.On circuit breaker panel 121VU:
| No change. |
| 9.Close the four passenger/crew doors and the four flaps that give access to the control handles of the emergency exit doors. | On the lower ECAM DU, on the "DOOR/OXY" page:
|
| 10.Close the four avionics compartment doors, the two cargo compartment doors (Ref. AMM TASK 52-30-00-860-002) and the bulk cargo-compartment door. | On the lower ECAM DU, on the "DOOR/OXY" page:
|
11.On circuit breaker panel 121VU:
| |
12.On circuit breaker panel 49VU:
| |
A. Test of the Door Warning System
(Ref. AMM TASK 52-30-00-860-001) (Ref. AMM TASK 52-30-00-860-002)
Subtask 52-71-00-710-050-I ** ON A/C NOT FOR ALL (Ref. AMM TASK 52-30-00-860-001) (Ref. AMM TASK 52-30-00-860-002)
WARNING:
INSTALL A SAFETY BARRIER WHEN YOU OPEN A DOOR IF THE ACCESS PLATFORM IS NOT USED.
(1) Do the test that follows: | ACTION | RESULT |
|---|---|
| 1.On the ECAM control panel, push the DOOR key: | On the lower ECAM DU, on the "DOOR/OXY" page:
|
2.On circuit breaker panel 121VU:
| No change. |
3.On circuit breaker panel 121VU:
| No change. |
| 4.Open the four avionics compartment doors. | On the lower ECAM DU, on the "DOOR/OXY" page:
|
| 5.Open the two cargo compartment doors (Ref. AMM TASK 52-30-00-860-001). | On the lower ECAM DU, on the "DOOR/OXY" page:
|
| 6.Open the four passenger/crew doors and the two flaps that give access to the control handles of the emergency exit doors. | On the lower ECAM DU, on the "DOOR/OXY" page:
|
7.On circuit breaker panel 121VU:
| No change. |
| 8.Close the four passenger/crew doors and the two flaps that give access to the control handles of the emergency exit doors. | On the lower ECAM DU, on the "DOOR/OXY" page:
|
| 9.Close the four avionics compartment doors and the two cargo compartment doors (Ref. AMM TASK 52-30-00-860-002). | On the lower ECAM DU, on the "DOOR/OXY" page:
|
10.On circuit breaker panel 121VU:
| |
11.On circuit breaker panel 49VU:
| |
A. Test of the Door Warning System
(Ref. AMM TASK 52-30-00-860-001) (Ref. AMM TASK 52-30-00-860-002)
Subtask 52-71-00-710-050-N ** ON A/C NOT FOR ALL (Ref. AMM TASK 52-30-00-860-001) (Ref. AMM TASK 52-30-00-860-002)
WARNING:
INSTALL A SAFETY BARRIER WHEN YOU OPEN A DOOR IF THE ACCESS PLATFORM IS NOT USED.
(1) Do the test that follows: | ACTION | RESULT |
|---|---|
| 1.On the ECAM control panel, push the DOOR key. | On the lower ECAM DU, on the "DOOR/OXY" page:
|
2.On circuit breaker panel 121VU:
| No change. |
3.On circuit breaker panel 121VU:
| No change. |
| 4.Open the four avionics compartment doors. | On the lower ECAM DU, on the "DOOR/OXY" page:
|
| 5.Open the two cargo compartment doors (Ref. AMM TASK 52-30-00-860-001). | On the lower ECAM DU, on the "DOOR/OXY" page:
|
| 6.Open the bulk cargo-compartment door. | On the lower ECAM DU, on the "DOOR/OXY" page:
|
| 7.Open the four passenger/crew doors and the four emergency exit doors. | On the lower ECAM DU, on the "DOOR/OXY" page:
|
8.On circuit breaker panel 121VU:
| No change. |
| 9.Close the four passenger/crew doors and the four emergency exit doors. | On the lower ECAM DU, on the "DOOR/OXY" page:
|
| 10.Close the four avionics compartment doors, the two cargo compartment doors (Ref. AMM TASK 52-30-00-860-002) and the bulk cargo-compartment door. | On the lower ECAM DU, on the "DOOR/OXY" page:
|
11.On circuit breaker panel 121VU:
| |
12.On circuit breaker panel 49VU:
| |
A. Test of the Door Warning System
(Ref. AMM TASK 52-30-00-860-001) (Ref. AMM TASK 52-30-00-860-002)
5. Close-up(Ref. AMM TASK 52-30-00-860-001) (Ref. AMM TASK 52-30-00-860-002)
WARNING:
INSTALL A SAFETY BARRIER WHEN YOU OPEN A DOOR IF THE ACCESS PLATFORM IS NOT USED.
(1) Do the test that follows: | ACTION | RESULT |
|---|---|
| 1.On the ECAM control panel, push the DOOR key. | On the lower ECAM DU, on the "DOOR/OXY" page:
|
2.On circuit breaker panel 121VU:
| No change. |
3.On circuit breaker panel 121VU:
| No change. |
4.On circuit breaker panel 49VU:
| No change. |
| 5.Open the four avionics compartment access-doors. | On the lower ECAM DU, on the "DOOR/OXY" page:
|
| 6.Open the two cargo compartment doors (Ref. AMM TASK 52-30-00-860-001). | On the lower ECAM DU, on the "DOOR/OXY" page:
|
| 7.Open the bulk cargo-compartment door. | On the lower ECAM DU, on the "DOOR/OXY" page:
|
| 8.Open the four passenger/crew doors, the applicable emergency exit doors and the applicable overwing emergency-exit doors. | On the lower ECAM DU, on the "DOOR/OXY" page:
|
9.On circuit breaker panel 121VU:
| No change. |
| 10.Close the four passenger/crew doors, the applicable emergency exit doors and the applicable overwing emergency-exit doors. | On the lower ECAM DU, on the "DOOR/OXY" page:
|
| 11.Close the four avionics compartment access-doors, the two cargo compartment doors (Ref. AMM TASK 52-30-00-860-002) and the bulk cargo-compartment door. | On the lower ECAM DU, on the "DOOR/OXY" page:
|
12.On circuit breaker panel 121VU:
| |
13.On circuit breaker panel 49VU:
| |
Subtask 52-71-00-860-061-A
A. Put the aircraft back to its initial configuration.
(1) Do the EIS stop procedure (Ref. AMM TASK 31-60-00-860-002).
Subtask 52-71-00-865-081-A (1) Do the EIS stop procedure (Ref. AMM TASK 31-60-00-860-002).
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 52-71-00-410-071-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | LIGHTING/EMER LT/CABIN | 2WL | H06 |
| 49VU | LIGHTING/EMER LT/CABIN | 1WL | H05 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | LIGHTING/EMER LT/CABIN | 2WL | H04 |
| 49VU | LIGHTING/EMER LT/CABIN | 1WL | H03 |
| ** ON A/C ALL | |||
| 122VU | LIGHTING/CABIN/EMER/LT | 3WL | V07 |
C. Close Access
(1) Arm the escape slides of the emergency exits (3):
Disarming of the Emergency Exit Doors ** ON A/C NOT FOR ALL
Disarming of the Emergency Exit Doors ** ON A/C NOT FOR ALL
(a) Open and remove the cover flaps (2) from the emergency exit doors (3).
(b) Use the WRENCH - SPANNER to turn the head of the latch pin (1) a quarter turn clockwise to extend the latch pin (1).
(c) Make sure that the SLIDE ARMED indicator lights (4) come on.
(d) Install and close the cover flaps (2) on the emergency exit doors (3).
(e) Make sure that the SLIDE ARMED indicator lights (4) go off.
(2) Obey the special precautions after the work on the door (Ref. AMM TASK 52-10-00-860-002).
(3) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(4) Close the applicable passenger/crew door (Ref. AMM TASK 52-10-00-410-001).
(5) Remove the access platform(s).
(6) Make sure that the work area is clean and clear of tools and other items.
Subtask 52-71-00-410-071-B ** ON A/C NOT FOR ALL (1) Arm the escape slides of the emergency exits (3):
Disarming of the Emergency Exit Doors ** ON A/C NOT FOR ALL
Disarming of the Emergency Exit Doors ** ON A/C NOT FOR ALL (b) Use the WRENCH - SPANNER to turn the head of the latch pin (1) a quarter turn clockwise to extend the latch pin (1).
(c) Make sure that the SLIDE ARMED indicator lights (4) come on.
(d) Install and close the cover flaps (2) on the emergency exit doors (3).
(e) Make sure that the SLIDE ARMED indicator lights (4) go off.
(2) Obey the special precautions after the work on the door (Ref. AMM TASK 52-10-00-860-002).
(3) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(4) Close the applicable passenger/crew door (Ref. AMM TASK 52-10-00-410-001).
(5) Remove the access platform(s).
(6) Make sure that the work area is clean and clear of tools and other items.
C. Close Access
(1) Obey the special precautions after the work on the door (Ref. AMM TASK 52-10-00-860-002).
(2) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(3) Close the applicable passenger/crew door (Ref. AMM TASK 52-10-00-410-001).
(4) Obey the special precautions after the work on the emergency exit door (Ref. AMM TASK 52-22-00-860-004).
(5) Close the applicable emergency exit door (Ref. AMM TASK 52-22-00-410-002).
(6) Remove the access platform(s).
(7) Make sure that the work area is clean and clear of tools and other items.
Subtask 52-71-00-862-050-A (1) Obey the special precautions after the work on the door (Ref. AMM TASK 52-10-00-860-002).
(2) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(3) Close the applicable passenger/crew door (Ref. AMM TASK 52-10-00-410-001).
(4) Obey the special precautions after the work on the emergency exit door (Ref. AMM TASK 52-22-00-860-004).
(5) Close the applicable emergency exit door (Ref. AMM TASK 52-22-00-410-002).
(6) Remove the access platform(s).