Installation of the Pylon Interface Duct
TASK 36-11-49-400-042-A
Installation of the Pylon Interface Duct
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Expendable Parts
D. Referenced Information
3. Job Set-up
Subtask 36-11-49-860-059-A ** ON A/C NOT FOR ALL
Subtask 36-11-49-420-050-A ** ON A/C NOT FOR ALL
Subtask 36-11-49-865-052-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:10:24 UTC
Installation of the Pylon Interface Duct
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE |
| No specific | AR | HAMMER - FIBER |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR, 451AL, 452AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR, 461AL, 462AR | |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 10 | E-SEAL | AIPC 36-11-52-02-040 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 36-12-00-860-001-A | Pressurization of the Bleed System with the APU |
| TASK 36-12-00-860-002-A | Pressurization of the Bleed System through the HP Ground Connector |
| TASK 49-00-00-860-006-A | APU Shutdown by External Power |
| TASK 49-00-00-860-006-A-01 | APU Shutdown by Batteries |
| TASK 49-00-00-860-009-A | APU Shutdown by External Power (131-9(A)) |
| TASK 49-00-00-860-009-A-01 | APU Shutdown by Batteries (131-9(A)) |
| TASK 71-13-00-010-040-B | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-040-B | Closing of the Fan Cowl Doors |
| TASK 78-30-00-081-041-B | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-481-041-B | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-36-00-010-040-B | Opening of the Thrust Reverser Doors |
| TASK 78-36-00-410-040-B | Closing of the Thrust Reverser Doors |
Subtask 36-11-49-860-059-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the aircraft electrical circuits are energized (Ref. AMM TASK 24-41-00-861-002) or (Ref. AMM TASK 24-41-00-861-002).
(2) Make sure that engine 1(2) is shutdown for a minimum of 5 minutes before you do this procedure.
(3) In the cockpit, on AIR COND panel 30VU:
(a) Make sure that the ENG 1(2) BLEED pushbutton-switch is released (the OFF legend is on).
(b) Make sure that the APU BLEED pushbutton-switch is released (the ON legend is off).
(c) Make sure that the WARNING NOTICE(S) is(are) in position to tell persons not to operate the pneumatic system
(4) In the cockpit, on ENG panel 115VU:
(a) Make sure that the WARNING NOTICE(S) is(are) in position to tell persons not to start engine 1(2).
(5) On the HP ground connector:
(a) Make sure that the WARNING NOTICE(S) is(are) in position to tell persons not to pressurize the pneumatic system
(6) On the ENG section of maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR 1(2) pushbutton-switch is off.
(b) Make sure that the WARNING NOTICE(S) is(are) in position to tell persons not to energize FADEC 1(2).
(7) Make sure that the ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE is in position below the engine.
Subtask 36-11-49-010-074-A ** ON A/C NOT FOR ALL (1) Make sure that the aircraft electrical circuits are energized (Ref. AMM TASK 24-41-00-861-002) or (Ref. AMM TASK 24-41-00-861-002).
(2) Make sure that engine 1(2) is shutdown for a minimum of 5 minutes before you do this procedure.
(3) In the cockpit, on AIR COND panel 30VU:
(a) Make sure that the ENG 1(2) BLEED pushbutton-switch is released (the OFF legend is on).
(b) Make sure that the APU BLEED pushbutton-switch is released (the ON legend is off).
(c) Make sure that the WARNING NOTICE(S) is(are) in position to tell persons not to operate the pneumatic system
(4) In the cockpit, on ENG panel 115VU:
(a) Make sure that the WARNING NOTICE(S) is(are) in position to tell persons not to start engine 1(2).
(5) On the HP ground connector:
(a) Make sure that the WARNING NOTICE(S) is(are) in position to tell persons not to pressurize the pneumatic system
(6) On the ENG section of maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR 1(2) pushbutton-switch is off.
(b) Make sure that the WARNING NOTICE(S) is(are) in position to tell persons not to energize FADEC 1(2).
(7) Make sure that the ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE is in position below the engine.
B. Get Access
(1) Make sure that the fan cowl doors are open (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Make sure that the thrust reverser doors are open (Ref. AMM TASK 78-36-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 36-11-49-040-056-A ** ON A/C NOT FOR ALL Subtask 36-11-49-865-051-A ** ON A/C NOT FOR ALL (1) Make sure that the fan cowl doors are open (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Make sure that the thrust reverser doors are open (Ref. AMM TASK 78-36-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
D. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR BLEED/ENG 1/CTL | 3HA1 | D12 |
| 49VU | AIR BLEED/ENG 1/MONG | 2HA1 | D11 |
| 122VU | AIR BLEED/ENG 2/CTL | 3HA2 | Z23 |
| 122VU | AIR BLEED/ENG 2/MONG | 2HA2 | Z22 |
Subtask 36-11-49-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the Pylon Interface Duct
(1) If you use the APU to energize the electrical circuits, stop the APU:
(a) Make sure that the pressure and the temperature of the bleed-air duct system are in ambient conditions.
(4) Loosely install the pylon interface duct (15) between the pylon duct and the bleed PRV (20).
(5) Attach the interface duct (15) to the pylon duct with the coupling (5).
(6) Attach the pylon interface duct (15) to the bleed PRV (20) with a serviceable AIPC 36-11-52-02-040 E-SEAL (10) and the coupling (25).
(8) Make sure that the pylon interface duct (15) is in the correct position.
(9) TORQUE the coupling nuts, as follows:
(a) TORQUE the coupling nut to the value shown on the coupling.
(b) Tap the perimeter of the coupling with a HAMMER - FIBER, then torque the coupling nut again.
(c) Do the torque procedure two times, then torque the coupling nut again.
Subtask 36-11-49-720-055-A ** ON A/C NOT FOR ALL (1) If you use the APU to energize the electrical circuits, stop the APU:
- For GTCP 36-300 APU (Ref. AMM D/O 49-00-00-86)
- For APS 3200 APU (Ref. AMM TASK 49-00-00-860-006)
- For 131-9(A) APU (Ref. AMM TASK 49-00-00-860-009).
(a) Make sure that the pressure and the temperature of the bleed-air duct system are in ambient conditions.
WARNING:
MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING:
DO NOT TOUCH THE UNIT UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS WHEN YOU DO THE MAINTENANCE TASK(S).
(3) Remove the blanking plugs from the pylon interface duct, the pylon duct (15), and the bleed PRV (20). (4) Loosely install the pylon interface duct (15) between the pylon duct and the bleed PRV (20).
(5) Attach the interface duct (15) to the pylon duct with the coupling (5).
(6) Attach the pylon interface duct (15) to the bleed PRV (20) with a serviceable AIPC 36-11-52-02-040 E-SEAL (10) and the coupling (25).
CAUTION:
MAKE SURE THE SMOOTH CIRCULAR SURFACE OF THE COUPLING IS RADIALLY OUTBOARD FROM THE ENGINE. DO NOT LET THE COUPLING TOUCH ENGINE COMPONENTS OR STRUCTURE. DAMAGE TO THE COMPONENTS OR STRUCTURE COULD OCCUR.
(7) Tighten the nuts of the couplings (5) and (25) sufficiently to hold the duct in position. Do not torque the coupling nuts at this time.(8) Make sure that the pylon interface duct (15) is in the correct position.
(9) TORQUE the coupling nuts, as follows:
(a) TORQUE the coupling nut to the value shown on the coupling.
(b) Tap the perimeter of the coupling with a HAMMER - FIBER, then torque the coupling nut again.
(c) Do the torque procedure two times, then torque the coupling nut again.
B. Do this test:
(1) Pressurize the bleed system through the HP ground connector (Ref. AMM TASK 36-12-00-860-002) or with the APU (Ref. AMM TASK 36-12-00-860-001).
(2) 0n the panel 30VU, put the X-BLEED selector switch in the OPEN position.
(3) If you pressurize the bleed system through the HP ground connector, the supplied pressure 30 psi (2.07 bar) must be stable.
(4) Make sure that there are no leaks at the junctions of the installed duct.
5. Close-up(1) Pressurize the bleed system through the HP ground connector (Ref. AMM TASK 36-12-00-860-002) or with the APU (Ref. AMM TASK 36-12-00-860-001).
(2) 0n the panel 30VU, put the X-BLEED selector switch in the OPEN position.
(3) If you pressurize the bleed system through the HP ground connector, the supplied pressure 30 psi (2.07 bar) must be stable.
(4) Make sure that there are no leaks at the junctions of the installed duct.
Subtask 36-11-49-865-052-A ** ON A/C NOT FOR ALL
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 36-11-49-410-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR BLEED/ENG 1/CTL | 3HA1 | D12 |
| 49VU | AIR BLEED/ENG 1/MONG | 2HA1 | D11 |
| 122VU | AIR BLEED/ENG 2/CTL | 3HA2 | Z23 |
| 122VU | AIR BLEED/ENG 2/MONG | 2HA2 | Z22 |
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser cowl doors (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
(3) Remove the access platform(s).
Subtask 36-11-49-440-059-A ** ON A/C NOT FOR ALL Subtask 36-11-49-410-082-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser cowl doors (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
(3) Remove the access platform(s).
D. Close Access
(1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Remove the WARNING NOTICE(S).
Subtask 36-11-49-862-055-A ** ON A/C NOT FOR ALL (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Remove the WARNING NOTICE(S).
E. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002) or (Ref. AMM TASK 24-41-00-862-002).
(Ref. AMM TASK 24-41-00-862-002) or (Ref. AMM TASK 24-41-00-862-002).
Pylon Interface Duct