W DOC AIRBUS | AMM A320F

Installation of the Sense Line between the Pylon Interface and the Duct Assy


TASK 36-11-49-400-028-A
Installation of the Sense Line between the Pylon Interface and the Duct Assy


WARNING: MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 1M(3 FT)
No specific
AR
FOIL - ALUMINUM
No specific
AR
WARNING NOTICE(S)
No specific
Torque wrench: range to between 1.7 and 1.5 m.daN (12.54 and 11.06 lbf.ft ) T
No specific
Torque wrench: range to between 3.2 and 2.9 m.daN (23.60 and 21.39 lbf.ft ) T
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.14QEB1)
Wire-Locking Dia: 0.6 mm CRES Nickel Alloy -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR, 451AL, 452AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR, 461AL, 462AR
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 36-12-00-860-001-A
Pressurization of the Bleed System with the APU
TASK 36-12-00-860-002-A
Pressurization of the Bleed System through the HP Ground Connector
TASK 49-00-00-860-006-A
APU Shutdown by External Power
TASK 49-00-00-860-006-A-01
APU Shutdown by Batteries
TASK 49-00-00-860-009-A
APU Shutdown by External Power (131-9(A))
TASK 49-00-00-860-009-A-01
APU Shutdown by Batteries (131-9(A))
TASK 71-13-00-010-040-B
Opening of the Fan Cowl Doors
TASK 71-13-00-410-040-B
Closing of the Fan Cowl Doors
TASK 78-30-00-081-041-B
Make the Thrust Reverser Serviceable after Maintenance
TASK 78-30-00-481-041-B
Make the Thrust Reverser Unserviceable for Maintenance
TASK 78-36-00-010-040-B
Opening of the Thrust Reverser Doors
TASK 78-36-00-410-040-B
Closing of the Thrust Reverser Doors
3. Job Set-up
Subtask 36-11-49-860-109-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the aircraft electrical circuits are energized (Ref. AMM TASK 24-41-00-861-002) or (Ref. AMM TASK 24-41-00-861-002).
   (2) Make sure that engine 1(2) is shutdown for a minimum of 5 minutes before you do this procedure.
   (3) In the cockpit, on AIR COND panel 30VU:
     (a) Make sure that the ENG 1(2) BLEED pushbutton-switch is released (the OFF legend is on).
     (b) Make sure that the APU BLEED pushbutton-switch is released (the ON legend is off).
     (c) Make sure that the WARNING NOTICE(S) is(are) in position to tell persons not to operate the pneumatic system
   (4) In the cockpit, on ENG panel 115VU:
     (a) Make sure that the WARNING NOTICE(S) is(are) in position to tell persons not to start engine 1(2).
   (5) On the HP ground connector:
     (a) Make sure that the WARNING NOTICE(S) is(are) in position to tell persons not to pressurize the pneumatic system.
   (6) On the ENG section of maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR 1(2) pushbutton-switch is off.
     (b) Make sure that the WARNING NOTICE(S) is(are) in position to tell persons not to energize FADEC 1(2).
   (7) Make sure that the ACCESS PLATFORM 1M(3 FT) is in position below the applicable engine.
Subtask 36-11-49-010-187-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Make sure that the fan cowl doors are open (Ref. AMM TASK 71-13-00-010-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
   (2) Make sure that the thrust reverser doors are open (Ref. AMM TASK 78-36-00-010-040):
     (a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
     (b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
Subtask 36-11-49-040-138-A ** ON A/C NOT FOR ALL
C. Make sure that the Thrust Reverser is Unserviceable for Maintenance (Ref. AMM TASK 78-30-00-481-041).
Subtask 36-11-49-865-164-A ** ON A/C NOT FOR ALL
D. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR BLEED/ENG 1/CTL3HA1D12
49VUAIR BLEED/ENG 1/MONG2HA1D11
122VUAIR BLEED/ENG 2/CTL3HA2Z23
122VUAIR BLEED/ENG 2/MONG2HA2Z22
4. Procedure
Subtask 36-11-49-420-111-B ** ON A/C NOT FOR ALL
A. Installation of the Sense Line between the Pylon Interface and the Duct Assy
   (1) If you use the APU to energize the electrical circuits, stop the APU:
   (2) In the cockpit, on the SD bleed page:
     (a) Make sure that the pressure and the temperature of the bleed-air duct system are in ambient conditions.
WARNING: MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING: DO NOT TOUCH THE UNIT UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS WHEN YOU DO THE MAINTENANCE TASK(S).
   (3) Do an inspection of the component interfaces and the adjacent area.
   (4) Clean the component interfaces and the adjacent area.
   (5) Remove the plug from the duct assy (1).
   (6) Remove the PLUG-BLANKING from each disconnected line end.
   (7) Put the sense line (2) in position between the pylon interface (3) and the duct assy (1).
   (8) Install the washers (5) and the screws (6) on the pylon interface (3).
   (9) Tighten the screws (6).
   (10) Connect the sense line (2) to the port of the duct assy (1):
WARNING: TIGHTEN THE UNION(S) TO THE CORRECT TORQUE VALUE. IF YOU DO NOT TIGHTEN THEM SUFFICIENTLY, HOT AIR LEAKAGE CAN CAUSE INJURY TO PERSONS OR DAMAGE TO EQUIPMENT.
     (a) TORQUE the nut of the sense line (2) to between 1.7 and 1.5 m.daN (12.54 and 11.06 lbf.ft ) T.
   (11) Connect the sense line (4) to the sense line (2):
WARNING: TIGHTEN THE UNION(S) TO THE CORRECT TORQUE VALUE. IF YOU DO NOT TIGHTEN THEM SUFFICIENTLY, HOT AIR LEAKAGE CAN CAUSE INJURY TO PERSONS OR DAMAGE TO EQUIPMENT.
     (a) TORQUE the nut of the sense line (4) to between 3.2 and 2.9 m.daN (23.60 and 21.39 lbf.ft )
T.
Subtask 36-11-49-480-075-A ** ON A/C NOT FOR ALL
B. Prepare for the Leak Test
   (1) Do the steps that follow to install FOIL - ALUMINUM on the sense line connections on the duct assy and on the pylon interface:
  • Wind the foil wrap around the joint one time.
  • Twist the seam of the foil wrap tight.
  • Make the foil wrap as tight as possible on the tube but do not cause damage to the wrap.
  • Attach the foil wrap at the two sides of the pneumatic joint with lockwire 14QEB1Wire-Locking Dia: 0.6 mm CRES Nickel Alloy -.
Subtask 36-11-49-790-052-B ** ON A/C NOT FOR ALL
C. Leak Test
   (1) Pressurize the bleed system through the HP ground connector (
Ref. AMM TASK 36-12-00-860-002) or with the APU (Ref. AMM TASK 36-12-00-860-001).
     (a) Make sure that there are no leaks at the sense line connections.
NOTE: There is a leak when the foil installed on the pneumatic connection breaks or when it is too hot.
   (2) Remove the materials used to do the leak test.
5. Close-up
Subtask 36-11-49-410-161-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the thrust reverser doors (Ref. AMM TASK 78-36-00-410-040):
     (a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
     (b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
Subtask 36-11-49-440-104-A ** ON A/C NOT FOR ALL
B. Make the Thrust Reverser Serviceable after Maintenance (Ref. AMM TASK 78-30-00-081-041).
Subtask 36-11-49-865-165-A ** ON A/C NOT FOR ALL
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR BLEED/ENG 1/CTL3HA1D12
49VUAIR BLEED/ENG 1/MONG2HA1D11
122VUAIR BLEED/ENG 2/CTL3HA2Z23
122VUAIR BLEED/ENG 2/MONG2HA2Z22
Subtask 36-11-49-410-160-A ** ON A/C NOT FOR ALL
D. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
   (3) Remove the WARNING NOTICE(S).
   (4) Remove the access platform(s).
Subtask 36-11-49-862-098-A ** ON A/C NOT FOR ALL
E. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002) or (Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.01 01:10:46 UTC