Functional Check of ECAM Oxygen-Cylinder Contents Indication Compared with Cylinder Pressure Gauge
TASK 35-10-00-720-001-A
Functional Check of ECAM Oxygen-Cylinder Contents Indication Compared with Cylinder Pressure Gauge
1. Reason for the Job
Refer to the MPD TASK: 351000-08
FUNCTIONAL CHECK OF ECAM OXYGEN CYLINDER CONTENTS INDICATION COMPARED WITH CYLINDER PRESSURE GAUGE
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 35-10-00-010-059-A ** ON A/C NOT FOR ALL
Subtask 35-10-00-720-051-A ** ON A/C NOT FOR ALL
Subtask 35-10-00-410-057-B
[Rev.10 from 2021]
2026.04.01 01:03:51 UTC
Functional Check of ECAM Oxygen-Cylinder Contents Indication Compared with Cylinder Pressure Gauge
1. Reason for the Job
Refer to the MPD TASK: 351000-08
FUNCTIONAL CHECK OF ECAM OXYGEN CYLINDER CONTENTS INDICATION COMPARED WITH CYLINDER PRESSURE GAUGE
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 123 | NOSE GEAR WELL |
| 125 | LATERAL AVIONIC COMPARTMENT |
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| 812 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 31-60-00-860-002-A | EIS Stop Procedure |
| TASK 35-00-00-860-001-A | Special Precautions When Working on a Gaseous Oxygen System |
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
Subtask 35-10-00-010-059-A ** ON A/C NOT FOR ALL
A. Get access to the avionics compartment.
(1) Obey the special precautions when you do work on a gaseous oxygen system (Ref. AMM TASK 35-00-00-860-001).
(2) Put a WARNING NOTICE(S) in position to tell persons not to release the CREW SUPPLY pushbutton switch.
(3) Put an ACCESS PLATFORM 2M (6 FT) in position at access door 812.
(4) Open access door 812 (Ref. AMM TASK 52-41-00-010-002).
(5) Make sure that the valve of the oxygen storage cylinder (5750HM) is fully open.
(6) Put a WARNING NOTICE(S) in position to tell persons not to close the valve of oxygen storage cylinder 5750HM.
Subtask 35-10-00-010-059-B ** ON A/C NOT FOR ALL (1) Obey the special precautions when you do work on a gaseous oxygen system (Ref. AMM TASK 35-00-00-860-001).
(2) Put a WARNING NOTICE(S) in position to tell persons not to release the CREW SUPPLY pushbutton switch.
(3) Put an ACCESS PLATFORM 2M (6 FT) in position at access door 812.
(4) Open access door 812 (Ref. AMM TASK 52-41-00-010-002).
(5) Make sure that the valve of the oxygen storage cylinder (5750HM) is fully open.
(6) Put a WARNING NOTICE(S) in position to tell persons not to close the valve of oxygen storage cylinder 5750HM.
A. Get access to the avionics compartment.
(1) Obey the special precautions when you do work on a gaseous oxygen system (Ref. AMM TASK 35-00-00-860-001).
(2) Put a WARNING NOTICE(S) in position to tell persons not to release the CREW SUPPLY pushbutton switch.
(3) Put an ACCESS PLATFORM 2M (6 FT) in position at access door 812.
(4) Open access door 812 (Ref. AMM TASK 52-41-00-010-002).
(5) Make sure that the two manual shutoff-valves of the crew oxygen-storage cylinders 5750HM1 and 5750HM2 are fully open.
(6) Put a WARNING NOTICE(S) in position to tell persons not to close the two manual shutoff-valves of the crew oxygen-storage cylinders 5750HM1 and 5750HM2.
Subtask 35-10-00-860-063-A (1) Obey the special precautions when you do work on a gaseous oxygen system (Ref. AMM TASK 35-00-00-860-001).
(2) Put a WARNING NOTICE(S) in position to tell persons not to release the CREW SUPPLY pushbutton switch.
(3) Put an ACCESS PLATFORM 2M (6 FT) in position at access door 812.
(4) Open access door 812 (Ref. AMM TASK 52-41-00-010-002).
(5) Make sure that the two manual shutoff-valves of the crew oxygen-storage cylinders 5750HM1 and 5750HM2 are fully open.
(6) Put a WARNING NOTICE(S) in position to tell persons not to close the two manual shutoff-valves of the crew oxygen-storage cylinders 5750HM1 and 5750HM2.
B. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
Subtask 35-10-00-865-054-A (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
C. Make sure that this(these) circuit breaker(s) is(are) closed:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | OXYGEN/CREW/OXY/SPLY | 1HT | HA01 |
Subtask 35-10-00-720-051-A ** ON A/C NOT FOR ALL
A. Test
Subtask 35-10-00-720-051-B ** ON A/C NOT FOR ALL | ACTION | RESULT |
|---|---|
1.On the ECAM control panel:
| On the lower ECAM display unit:
|
2.On the lower ECAM display unit, on the DOOR/OXY page:
| |
3.In the avionics compartment:
| |
| 4.Compare the oxygen pressure values recorded on the DOOR/OXY page and on the direct-reading pressure gauge. | Make sure that the oxygen pressure values are the same, approximately plus or minus 100 psi (6.89 bar). |
A. Test
5. Close-up| ACTION | RESULT |
|---|---|
1.On the ECAM control panel:
| On the lower ECAM DU:
|
2.On the lower ECAM DU, on the DOOR/OXY page:
| |
3.In the avionics compartment:
| |
4.Compare the oxygen pressure values:
| Make sure that the oxygen pressure values are the same, approximately plus or minus 100 psi (6.89 bar). |
Subtask 35-10-00-410-057-B
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) In the avionics compartment:
(4) Remove the access platform(s).
Subtask 35-10-00-860-064-B (1) Make sure that the work area is clean and clear of tools and other items.
(2) In the avionics compartment:
- Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).
B. Put the aircraft back to its initial configuration.
(1) In the cockpit:
(Ref. AMM TASK 31-60-00-860-002).
(3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(1) In the cockpit:
- Remove the WARNING NOTICE(S).
(Ref. AMM TASK 31-60-00-860-002).
(3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).