W DOC AIRBUS | AMM A320F

Installation of the Cabin Intercommunication Data System (CIDS) Data Converter


TASK 33-21-32-400-801-A
Installation of the Cabin Intercommunication Data System (CIDS) Data Converter


ZONE: 240
FIN: 581LG ** ON A/C NOT FOR ALL
FIN: 582LG ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
STEPLADDER 1.0 M (3.3 FT)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
240
MID PASSENGER COMPARTMENT
FOR [581LG] (CONVERTER-DATA)
FOR [582LG] (CONVERTER-DATA)
241EC
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 25-23-41-000-001-A
Removal of the Ceiling Panels
TASK 33-21-00-710-001-A
Operational Test of the General Illumination
TASK 33-21-00-740-002-A
Bite Test of the General Illumination with the MCDU
FOR [581LG] (CONVERTER-DATA)
FOR [582LG] (CONVERTER-DATA)
TASK 25-23-41-400-001-A
Installation of the Ceiling Panels
3. Job Set-up
Subtask 33-21-32-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the aircraft electrical circuits are energized
(Ref. AMM TASK 24-41-00-861-002).
   (2) Make sure that the STEPLADDER 1.0 M (3.3 FT) is in the position below the related ceiling panel.
   (3) Make sure that the related ceiling panel is removed (Ref. AMM TASK 25-23-41-000-001).
Subtask 33-21-32-865-051-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2000VULIGHT-HATRACK-STRIP312LGJ05
4. Procedure
Subtask 33-21-32-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the CIDS Data Converter
   (1) Clean the component interfaces and the adjacent area.
   (2) Do an inspection of the component interfaces and the adjacent area.
   (3) Install the CIDS data converter (2) on the clip (1).
   (4) Make sure that the CIDS data converter (2) is engaged on the clip (1) correctly.
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
   (5) Connect the electrical connector (3).
Subtask 33-21-32-865-052-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2000VULIGHT-HATRACK-STRIP312LGJ05
Subtask 33-21-32-710-050-A ** ON A/C NOT FOR ALL
C. Test of the Underbin LED Light Strips and the Data Coverter(s):
   (1) Do the BITE test of the general illumination with the MCDU (Ref. AMM TASK 33-21-00-740-002).
   (2) Do the operational test of the scenario lighting from the Flight Attendant Panel (FAP) (Ref. AMM TASK 33-21-00-710-001).
5. Close-up
Subtask 33-21-32-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the ceiling panel:
     (a) FOR [581LG] (CONVERTER-DATA), [582LG] (CONVERTER-DATA)
Install 241EC (Ref. AMM TASK 25-23-41-400-001).
   (3) Remove the STEPLADDER 1.0 M (3.3 FT).
Subtask 33-21-32-862-050-A ** ON A/C NOT FOR ALL
B. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.01 00:53:30 UTC