Installation of the Smart PCMCIA Card (SPC) of the FDIMU
TASK 31-36-00-400-805-A
Installation of the Smart PCMCIA Card (SPC) of the FDIMU
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 31-36-00-861-089-A ** ON A/C NOT FOR ALL
Subtask 31-36-00-400-057-A ** ON A/C NOT FOR ALL
Subtask 31-36-00-865-175-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 08:35:54 UTC
Installation of the Smart PCMCIA Card (SPC) of the FDIMU
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | 1 | SMART PCMCIA CARD |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 128 | REAR AVIONIC COMPARTMENT |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 31-36-00-710-802-A | Operational Check of Cellular Radio Interlock Logic |
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
Subtask 31-36-00-861-089-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the aircraft electrical circuits are energized (Ref. AMM TASK 24-41-00-861-002).
Subtask 31-36-00-010-098-A ** ON A/C NOT FOR ALL (1) Make sure that the aircraft electrical circuits are energized (Ref. AMM TASK 24-41-00-861-002).
B. Get Access
(1) Make sure that the ACCESS PLATFORM 2M (6 FT) is in position at access door 824 in zone 128.
(2) Make sure that access door 824 is open (Ref. AMM TASK 52-41-00-010-002).
Subtask 31-36-00-865-174-A ** ON A/C NOT FOR ALL (1) Make sure that the ACCESS PLATFORM 2M (6 FT) is in position at access door 824 in zone 128.
(2) Make sure that access door 824 is open (Ref. AMM TASK 52-41-00-010-002).
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | AIDS & RCDR/FDIMU | 5TV | K15 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | AIDS & RCDR/FDIMU | 5TV | K38 |
Subtask 31-36-00-400-057-A ** ON A/C NOT FOR ALL
A. Install the Smart PCMCIA Card (SPC)
(1) Open the cover.
(2) Insert the SMART PCMCIA CARD carefully into the interface until the card has connected with the contacts.
(3) Close the cover.
5. Close-up(1) Open the cover.
(2) Insert the SMART PCMCIA CARD carefully into the interface until the card has connected with the contacts.
(3) Close the cover.
Subtask 31-36-00-865-175-A ** ON A/C NOT FOR ALL
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 31-36-00-710-141-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | AIDS & RCDR/FDIMU | 5TV | K15 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | AIDS & RCDR/FDIMU | 5TV | K38 |
B. Test of the Interlock of the SPC installation
(1) Do the Interlock test of the SPC (Ref. AMM TASK 31-36-00-710-802).
Subtask 31-36-00-410-097-A ** ON A/C NOT FOR ALL (1) Do the Interlock test of the SPC (Ref. AMM TASK 31-36-00-710-802).
C. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close access door 824 (Ref. AMM TASK 52-41-00-410-002).
(3) Remove the access platform(s).
Subtask 31-36-00-862-091-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close access door 824 (Ref. AMM TASK 52-41-00-410-002).
(3) Remove the access platform(s).
D. Aircraft Maintenance Configuration
(1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
Smart PCMCIA Card (SPC) of the FDIMU