W DOC AIRBUS | AMM A320F

Operational Check of Cellular Radio Interlock Logic


TASK 31-36-00-710-802-A
Operational Check of Cellular Radio Interlock Logic


ZONE: 121
1. Reason for the Job
Refer to the MPD TASK: 313300-09
OPERATIONAL CHECK OF CELLULAR RADIO INTERLOCK LOGIC
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
121
AVIONICS COMPARTMENT
824
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 31-36-00-400-805-A
Installation of the Smart PCMCIA Card (SPC) of the FDIMU
TASK 32-00-00-860-001-A
Flight Configuration Precautions with Electrical Power
TASK 32-00-00-860-001-A-01
Flight Configuration Precautions without Electrical Power
TASK 32-00-00-860-002-A
Ground Configuration after Flight Configuration with Electrical Power
TASK 32-00-00-860-002-A-01
Ground Configuration after Flight Configuration without Electrical Power
TASK 52-10-00-010-001-A
Opening of the Passenger/Crew Door
TASK 52-10-00-410-001-A
Closing of the Passenger/Crew Door
TASK 52-41-00-010-002-A
Open the Avionics Compartment Doors for Access
TASK 52-41-00-410-002-A
Close the Avionics Compartment Doors after Access
TASK 31-36-00-00-02
AIDS INTERCONNECTION (DMU, DAR) - DESCRIPTION AND OPERATION
3. Job Set-up
Subtask 31-36-00-860-145-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the aircraft is in Ground configuration (Landing Gear compressed and all Engines stopped).
   (2) Make sure that the Smart PCMCIA Card (SPC) is installed in FDIMU (Ref. AMM TASK 31-36-00-400-805).
   (3) Make sure that the left forward passenger door is in open position (Ref. AMM TASK 52-10-00-010-001).
   (4) Do the flight configuration precautions with electrical power (Ref. AMM TASK 32-00-00-860-001).
   (5) On the overhead panel 50VU, push the ENG FADEC GND PWR 1 pushbutton switch (the white ON indicator light comes on).
   (6) On the overhead panel 50VU, push the ENG FADEC GND PWR 2 pushbutton switch (the white ON indicator light comes on).
   (7) On the ENG panel 115VU, make sure that the ENG/MODE selector switch is in NORM position.
   (8) On the ENG panel 115VU, set the ENG/MASTER 2 switch 2KC to OFF position.
Subtask 31-36-00-010-099-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE below the access door 824.
   (2) Open the access door 824 (Ref. AMM TASK 52-41-00-010-002).
   (3) For location of the FDIMU, refer to Para. Component Location (Ref. AMM D/O 31-36-00-00).
Subtask 31-36-00-865-172-A ** ON A/C NOT FOR ALL
C. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUENGINE/2/FADEC A/AND EIU 22KS2A05
49VUENGINE/1/FADEC A/AND EIU 12KS1A04
** ON A/C NOT FOR ALL
121VUAIDS & RCDR/FDIMU5TVK15
121VUENGINE/ENG2/FADEC B/AND EIU24KS2Q40
121VUENGINE/ENG1/FADEC B/AND EIU 14KS1R41
** ON A/C NOT FOR ALL
121VUAIDS & RCDR/FDIMU5TVK38
121VUENGINE/ENG2/FADEC B/AND EIU24KS2R41
121VUENGINE/ENG1/FADEC B/AND EIU 14KS1R40
4. Procedure
Subtask 31-36-00-710-140-A ** ON A/C NOT FOR ALL
A. Do a WEFA software status:
ACTION
RESULT
On the MCDU, in cockpit:
On the MCDU display:
  • Push the line the line key adjacent to MCDU MENU indication.
  • The MCDU MENU page comes into view.
  • Select:
    <AIDS
    <PCMCIA
    <WEFA
    <MAINTENANCE
  • AIDS WEFA STATUS page comes into view.
Check the WEFA STATUS is ENABLED*
  • If the WEFA STATUS is DISABLED*, select the WEFA STATUS adjacent line.
  • The WEFA STATUS will change to ENABLED*.
NOTE: The access to the ENABLED/DISABLED line is protected by a password. The standard password is SFIMP. The standard password is no longer applicable if it is changed. Protection becomes active again once DMU has logged off from the MCDU.
Subtask 31-36-00-710-142-A ** ON A/C NOT FOR ALL
B. Do a check of the WEFA hardware status:
ACTION
RESULT
Make sure that the DMU FAIL LED and the FDIU FAIL LED are OFF.
Make sure that the ON/OFF switch is in the ON position.
  • Check the LED of the SPC which is installed in the FDIMU (10TV).
The SPC Status LED (top LED) has to be GREEN or ORANGE.
NOTE: The SPC Transfer LED (antenna symbol/bottom LED) is OFF at the start (approximately 2 minutes).
The SPC Transfer LED is only "ORANGE" when the network is found (approximately 10 seconds).
The SPC Transfer LED is "GREEN" when the network is connected.
Subtask 31-36-00-710-144-A ** ON A/C NOT FOR ALL
C. Do a check of the RF-Interlock
ACTION
RESULT
In the electronic bay (80VU):

  • Check on the FDIMU (10TV) front panel the SPC Status LED (top LED).
  • The SPC Status LED (top LED) is GREEN.
Close and lock the Left Forward Passenger Door (Ref. AMM TASK 52-10-00-410-001).
  • Check on the FDIMU (10TV) front panel the SPC Status LED (top LED).
  • The SPC Status LED (top LED) is ORANGE.
Unlock and open the Left Forward Passenger Door (Ref. AMM TASK 52-10-00-010-001).
  • Check on the FDIMU (10TV) front panel the SPC Status LED (top LED).
  • The SPC Status LED (top LED) is GREEN.
On the ENG panel 115VU:

  • Make sure that the ENG/MODE switch is in the NORM position.
  • Set the ENG/MASTER 2 switch 2KC to ON.
In the electronic bay (80VU):

  • Check on the FDIMU (10TV) front panel the SPC Status LED (top LED).
  • The SPC Status LED (top LED) is ORANGE.
On the ENG panel 115VU:

  • Set the ENG/MASTER 2 switch 2KC to OFF.
In the electronic bay (80VU):

Check on the FDIMU (10TV) front panel the SPC Status LED (top LED).
The SPC Status LED (top LED) is GREEN.
Subtask 31-36-00-865-177-A ** ON A/C NOT FOR ALL
D. Open this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUENGINE/2/FADEC A/AND EIU 22KS2A05
49VUENGINE/1/FADEC A/AND EIU 12KS1A04
** ON A/C NOT FOR ALL
121VUENGINE/ENG2/FADEC B/AND EIU24KS2Q40
121VUENGINE/ENG1/FADEC B/AND EIU 14KS1R41
** ON A/C NOT FOR ALL
121VUENGINE/ENG2/FADEC B/AND EIU24KS2R41
121VUENGINE/ENG1/FADEC B/AND EIU 14KS1R40
Subtask 31-36-00-710-145-A ** ON A/C NOT FOR ALL
E. Do a check of the RF-Interlock
ACTION
RESULT
In the electronic bay (80VU):

  • Check on the FDIMU (10TV) front panel the SPC Status LED (top LED).
  • The SPC Status LED (top LED) is ORANGE.
Subtask 31-36-00-865-178-A ** ON A/C NOT FOR ALL
F. Close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUENGINE/2/FADEC A/AND EIU 22KS2A05
49VUENGINE/1/FADEC A/AND EIU 12KS1A04
** ON A/C NOT FOR ALL
121VUENGINE/ENG2/FADEC B/AND EIU24KS2Q40
121VUENGINE/ENG1/FADEC B/AND EIU 14KS1R41
** ON A/C NOT FOR ALL
121VUENGINE/ENG2/FADEC B/AND EIU24KS2R41
121VUENGINE/ENG1/FADEC B/AND EIU 14KS1R40
Subtask 31-36-00-710-146-A ** ON A/C NOT FOR ALL
G. Do a check of the RF-Interlock
ACTION
RESULT
In the electronic bay (80VU):

  • Check on the FDIMU (10TV) front panel the SPC Status LED (top LED).
  • The SPC Status LED (top LED) is GREEN.
5. Close-up
Subtask 31-36-00-860-146-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Do the ground configuration after flight configuration with electrical power (Ref. AMM TASK 32-00-00-860-002).
   (2) On the overhead panel 50VU, push the ENG FADEC GND PWR 1 pushbutton switch (the white ON indicator light goes off).
   (3) On the overhead panel 50VU, push the ENG FADEC GND PWR 2 pushbutton switch (the white ON indicator light goes off).
   (4) Make sure that the work area is clean and clear of tools and other items.
   (5) Close the access door 824 (Ref. AMM TASK 52-41-00-410-002).
   (6) Remove the access platform(s).
[Rev.10 from 2021] 2026.04.01 00:36:05 UTC