W DOC AIRBUS | AMM A320F

Operational Test of the Thrust Reverser System


TASK 27-92-00-040-003-A
Operational Test of the Thrust Reverser System


ZONE: 210
1. Reason for the Job
MMEL 27-92-02A
GROUND SPOILER CONTROL SYSTEM (FAA ONLY)
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 78-31-00-710-040-A
Operational Test of the Thrust Reverser System
TASK 78-31-00-710-040-A-01
Operational Test of the Thrust Reverser without CFDS - Engine not Running
TASK 78-31-00-710-040-A-02
Operational Test of the Thrust Reverser without CFDS - Engine Running
TASK 78-31-00-710-041-A
Operational Test of the Thrust Reverser System with the CFDS
TASK 78-31-00-710-041-A-02
Operational test of the Thrust Reverser without the CFDS and Engine Running
TASK 78-31-00-710-042-A
Operational Test of the Thrust Reverser System
TASK 78-31-00-710-805-A
Operational Test of Thrust Reverser with MCDU
TASK 78-31-00-710-805-A-01
Thrust Reverser Cycling Test (Engine Running)
3. Job Set-up
Subtask 27-92-00-861-052-A
A. Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
Subtask 27-92-00-875-050-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/SEC1/NORM/SPLY21CE1B08
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/SEC1/NORM/SPLY21CE1B03
** ON A/C ALL
105VUFLT CTL/SEC1/STBY SPLY22CEB01
121VUFLIGHT CONTROLS/SEC3/SPLY21CE3Q19
121VUFLIGHT CONTROLS/SEC2/SPLY21CE2Q18
Subtask 27-92-00-860-054-A
C. Aircraft Maintenance Configuration
   (1) On the overhead panel, on the FLT CTL section of panel 23VU:
  • Make sure that the SEC 1 pushbutton switch is pushed (on this pushbutton switch, the FAULT and OFF legends are off).
   (2) On the overhead panel, on the FLT CTL section of panel 24VU:
  • Make sure that the SEC 2 and SEC 3 pushbutton switches are pushed (on these pushbutton switches, the FAULT and OFF legends are off).
4. Procedure
Subtask 27-92-00-710-052-A ** ON A/C NOT FOR ALL
A. Do the operational test of the thrust reverser system (Ref. AMM TASK 78-31-00-710-040)
Subtask 27-92-00-710-052-B ** ON A/C NOT FOR ALL
A. Do the operational test of the thrust reverser system (Ref. AMM TASK 78-31-00-710-041)
Subtask 27-92-00-710-052-E ** ON A/C NOT FOR ALL
A. Do the operational test of the thrust reverser system (Ref. AMM TASK 78-31-00-710-042)
Subtask 27-92-00-710-052-G ** ON A/C NOT FOR ALL
A. Do the operational test of the thrust reverser system (Ref. AMM TASK 78-31-00-710-805).
5. Close-up
Subtask 27-92-00-862-051-A
A. Put the aircraft back to its initial configuration.
   (1) Make an applicable entry in the logbook.
   (2) De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.03.31 23:58:28 UTC