Discard Demister Filter Element and Filter Cartridge (LE BOZEC)
TASK 21-26-43-600-016-A
Discard Demister Filter Element and Filter Cartridge (LE BOZEC)
Refer to the MPD TASK: 212600-11
DISCARD DEMISTER FILTER ELEMENT AND FILTER CARTRIDGE (LE BOZEC)
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Expendable Parts
D. Referenced Information
3. Job Set-up
Subtask 21-26-43-862-121-A ** ON A/C NOT FOR ALL Subtask 21-26-43-861-110-A ** ON A/C NOT FOR ALL Subtask 21-26-43-865-134-A ** ON A/C NOT FOR ALL
Subtask 21-26-43-020-089-E ** ON A/C NOT FOR ALL
Subtask 21-26-43-410-086-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 04:07:49 UTC
Discard Demister Filter Element and Filter Cartridge (LE BOZEC)
WARNING:
PUT ON GLOVES, A COVERALL WITH A HOOD, GOGGLES AND A PARTICULATE RESPIRATOR BEFORE YOU TOUCH THE FILTER. THE FILTER REMOVES SMALL PARTICLES (SMOKE, DUST, LINT, FIBERS, POLLEN) AND INFECTIOUS MATERIALS (BACTERIA, VIRUSES, MOLD SPORES, FUNGI) FROM THE AIR. THESE MATERIALS CAN CAUSE ILLNESS.
WARNING:
DO NOT LET THE FILTER TOUCH YOUR SKIN. DO NOT SHAKE OR HIT THE FILTER. DO NOT LET THE FILTER FALL. DO NOT USE COMPRESSED AIR TO CLEAN THE FILTER OR FILTER HOUSING. THIS CAN CAUSE THE INFECTIOUS MATERIAL TO BECOME AIRBORNE. DISCARD THE FILTER IN A PLASTIC DISPOSAL BAG. IF YOU DO NOT OBEY THESE INSTRUCTIONS, INFECTIOUS MATERIAL FROM THE FILTER CAN CAUSE ILLNESS.
WARNING:
PUT ALL AIR FILTERS THAT YOU REMOVE FROM THE AIRCRAFT INTO PLASTIC DISPOSAL BAGS. AIR FILTERS CAN CONTAIN INFECTIOUS MATERIALS WHICH CAN CAUSE ILLNESS. OBEY AIRLINE POLICY AND LOCAL HEALTH DEPARTMENT AND LAW ENFORCEMENT REGULATIONS FOR DISPOSAL OF INFECTIOUS MATERIALS.
CAUTION:
USE ONLY THE GROUND SERVICE NETWORK TO SUPPLY ELECTRICITY BECAUSE THE AVIONICS VENTILATION SYSTEM IS NOT SERVICEABLE. IF YOU ENERGIZE THE AIRCRAFT ELECTRICAL CIRCUITS WITHOUT THE VENTILATION SYSTEM YOU WILL CAUSE DAMAGE TO ELECTRICAL EQUIPMENT.
ZONE: 127
1. Reason for the JobRefer to the MPD TASK: 212600-11
DISCARD DEMISTER FILTER ELEMENT AND FILTER CARTRIDGE (LE BOZEC)
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 127 | REAR AVIONIC COMPARTMENT |
| 824 |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 4 | FILTER CARTRIDGE | AIPC 21-26-43-02-060 |
| 1 | DEMISTER FILTER | AIPC 21-26-43-02-070 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
Subtask 21-26-43-862-121-A ** ON A/C NOT FOR ALL Subtask 21-26-43-861-110-A ** ON A/C NOT FOR ALL Subtask 21-26-43-865-134-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 21-26-43-010-091-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/AVNCS VENT/CTL | 6HQ | D06 |
| 49VU | AIR COND/AVNCS VENT/CTL | 5HQ | D05 |
| 122VU | AIR COND/AVNCS/VENT/MONG | 3HQ | Y17 |
| 123VU | AVNCS VENT/EXTC/FAN | 2HQ | AC04 |
| 123VU | AVNCS VENT/BLOWER/FAN | 1HQ | AD10 |
D. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 824.
(2) Open the access door 824 (Ref. AMM TASK 52-41-00-010-002).
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 824.
(2) Open the access door 824 (Ref. AMM TASK 52-41-00-010-002).
Subtask 21-26-43-020-089-E ** ON A/C NOT FOR ALL
A. Removal of the Filter Cartridge
(1) Turn the door fasteners (3) of the filter housing (2) and open the door.
(2) Push the cartridge clamp (5) and remove the filter cartridge (4).
(3) Discard the filter cartridge (4).
Subtask 21-26-43-020-078-A ** ON A/C NOT FOR ALL (1) Turn the door fasteners (3) of the filter housing (2) and open the door.
(2) Push the cartridge clamp (5) and remove the filter cartridge (4).
(3) Discard the filter cartridge (4).
B. Removal of the Demister Filter
(1) Turn the door fasteners (3) of the filter housing (2) and open the door.
(2) Remove the demister filter (1) and discard it.
Subtask 21-26-43-210-078-A ** ON A/C NOT FOR ALL (1) Turn the door fasteners (3) of the filter housing (2) and open the door.
(2) Remove the demister filter (1) and discard it.
C. Clean the component interfaces and the adjacent area.
Subtask 21-26-43-420-087-D ** ON A/C NOT FOR ALL D. Installation of the Filter Cartridge
(1) Put a new AIPC 21-26-43-02-060 FILTER CARTRIDGE (4) in position in the filter housing (2).
(2) Pull the cartridge clamp (5) to prevent movement of the filter cartridge (4).
(3) Turn and safety the door fasteners (3) of the filter housing (2) to close the door.
Subtask 21-26-43-420-079-A ** ON A/C NOT FOR ALL (1) Put a new AIPC 21-26-43-02-060 FILTER CARTRIDGE (4) in position in the filter housing (2).
(2) Pull the cartridge clamp (5) to prevent movement of the filter cartridge (4).
(3) Turn and safety the door fasteners (3) of the filter housing (2) to close the door.
E. Installation of the Demister Filter
(1) Put a new AIPC 21-26-43-02-070 DEMISTER FILTER (1) in position in the filter housing (2).
(2) Make sure that the demister filter (1) is correctly installed in the filter housing (2).
(3) Turn and safety the door fasteners (3) of the filter housing (2) to close the door.
5. Close-up(1) Put a new AIPC 21-26-43-02-070 DEMISTER FILTER (1) in position in the filter housing (2).
(2) Make sure that the demister filter (1) is correctly installed in the filter housing (2).
(3) Turn and safety the door fasteners (3) of the filter housing (2) to close the door.
Subtask 21-26-43-410-086-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 824 (Ref. AMM TASK 52-41-00-410-002).
(3) Remove the access platform(s).
Subtask 21-26-43-865-135-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 824 (Ref. AMM TASK 52-41-00-410-002).
(3) Remove the access platform(s).
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 21-26-43-861-127-A ** ON A/C NOT FOR ALL Subtask 21-26-43-862-106-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/AVNCS VENT/CTL | 6HQ | D06 |
| 49VU | AIR COND/AVNCS VENT/CTL | 5HQ | D05 |
| 122VU | AIR COND/AVNCS/VENT/MONG | 3HQ | Y17 |
| 123VU | AVNCS VENT/EXTC/FAN | 2HQ | AC04 |
| 123VU | AVNCS VENT/BLOWER/FAN | 1HQ | AD10 |
Demister Air Filter Element and Filter Cartridge (LE BOZEC)