W DOC AIRBUS | AMM A320F

General Visual Inspection of Upper Forward Pylon (EWIS)


TASK 05-24-10-200-001-A
General Visual Inspection of Upper Forward Pylon (EWIS)


ZONE: 411
ZONE: 413
ZONE: 414
ZONE: 421
ZONE: 423
ZONE: 424
1. Reason for the Job
Refer to the MPD TASK: ZL-411-01
GENERAL VISUAL INSPECTION OF UPPER FORWARD PYLON (EWIS)
NOTE: This is an EWIS (Electrical Wiring Interconnection System) procedure. EWIS is defined in ESPM 20-33-11.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
411
PYLON LEADING EDGE
413
UPPER FWD PYLON
414
UPPER FWD PYLON
421
PYLON LEADING EDGE
423
UPPER FWD PYLON
424
UPPER FWD PYLON
413AL, 413BL, 413CL, 423AL, 423BL, 423CL
413AR, 413BR, 413CR, 423AR, 423BR, 423CR, 471AL, 471AR, 481AL, 481AR
413DL, 414AR, 414BR, 414CR, 424AR, 424BR, 424CR
413EL, 414FR, 423DL, 423FL, 424ER
411AL, 413AT, 413BT, 413CT, 413ET, 421AL, 423AT, 423BT, 423CT, 423ET, 424DR
414AZ, 423AZ
413DT, 423DT
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 54-52-11-000-001-A
Removal of the Pressure Relief Doors
TASK 54-52-11-000-002-A
Removal of the Access Panels
TASK 54-52-11-000-002-B
Removal of the Access Panels
TASK 54-52-11-000-805-A
Removal of the Access Skin Panels
TASK 54-52-11-400-001-A
Installation of the Pressure Relief Doors
TASK 54-52-11-400-002-A
Installation of the Access Panels
TASK 54-52-11-400-002-B
Installation of the Access Panels
TASK 54-52-11-400-805-A
Installation of the Access Skin Panels
TASK 54-53-11-000-002-A
Removal of the Pylon-to-Wing Access Panels
TASK 54-53-11-000-002-B
Removal of the Pylon-to-Wing Access Panels
TASK 54-53-11-000-804-A
Removal of the Pylon-to-Wing Access Panels and Doors
TASK 54-53-11-400-002-A
Installation of the Pylon-to-Wing Access Panels
TASK 54-53-11-400-002-B
Installation of the Pylon-to-Wing Access Panels
TASK 54-53-11-400-804-A
Installation of the Pylon-to-Wing Access Panels and Doors
3. Job Set-up
Subtask 05-24-10-010-050-B ** ON A/C NOT FOR ALL Subtask 05-24-10-010-050-E ** ON A/C NOT FOR ALL
A. Get Access
   (1) Put the ACCESS PLATFORM 2M (6 FT) in position below the applicable zones.
   (2) Remove the access panels (Ref. AMM TASK 54-52-11-000-002) and (Ref. AMM TASK 54-53-11-000-002):
   (3) Open the pressure relief doors:
- For the left pylon 413BL and 413BR
- For the right pylon 423BL and 423BR.
Subtask 05-24-10-010-050-G ** ON A/C NOT FOR ALL
A. Get Access
   (1) Put an ACCESS PLATFORM 2M (6 FT) in position at zone 410 (420).
   (2) Remove the access panels (Ref. AMM TASK 54-52-11-000-805) and (Ref. AMM TASK 54-53-11-000-804):
4. Procedure
Subtask 05-24-10-210-050-A
A. Inspection
   (1) Do a general visual inspection of the upper forward pylon (zones 411, 413, 414, 421, 423, and 424).
   (2) Make sure that there are no signs of corrosion, cracks or damage.
   (3) Make sure that all the installations (wiring, ducting, piping) are correctly attached.
5. Close-up
Subtask 05-24-10-410-050-B ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the access panels (Ref. AMM TASK 54-52-11-400-002), (Ref. AMM TASK 54-52-11-400-001) and (Ref. AMM TASK 54-53-11-400-002):
   (3) Remove the access platform(s).
Subtask 05-24-10-410-050-E ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the pressure relief doors:
- For the left pylon 413BL and 413BR
- For the right pylon 423BL and 423BR.
   (3) Install the access panels (Ref. AMM TASK 54-52-11-400-002) and (Ref. AMM TASK 54-53-11-400-002):
   (4) Remove the access platform(s).
Subtask 05-24-10-410-050-G ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the access panels (Ref. AMM TASK 54-52-11-400-805) and (Ref. AMM TASK 54-53-11-400-804):
   (3) Remove the access platform(s).
[Rev.10 from 2021] 2026.03.31 22:49:49 UTC