W DOC AIRBUS | AMM A320F

Removal of the Access Panels


TASK 54-52-11-000-002-B
Removal of the Access Panels


WARNING: BEFORE YOU START WORK, YOU MUST PUT ON A SAFETY HARNESS AND ATTACH IT TO THE ACCESS PLATFORM. WITHOUT A SAFETY HARNESS, YOU CAN FALL. THIS CAN KILL YOU OR CAUSE YOU INJURY.
WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
ZONE: 410
ZONE: 420
FIN: 1000EM1 ** ON A/C NOT FOR ALL
FIN: 1000EM2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
410
ENG 1 PYLON BOX AND FORWARD FAIRING
420
ENG 2 PYLON BOX AND FORWARD FAIRING
411AT, 411BT, 413AL, 413AR, 413CL, 413CR, 413DT, 421AT, 421BT, 423AL, 423AR, 423CL, 423CR, 423DT
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 54-52-12-300-001-A
Replacement of the Cantilever Cover Assemblies
TASK 78-30-00-040-012-A
Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance
TASK 78-30-00-481-041-B
Make the Thrust Reverser Unserviceable for Maintenance
F Access Panels ** ON A/C NOT FOR ALL
F Access Panels ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 54-52-11-941-060-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) in position to tell persons not to start the engine 1(2).
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) in position to tell persons not to energize the FADEC 1(2).
Subtask 54-52-11-010-056-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position:
     (a) For the left pylon, in zone 410
     (b) For the right pylon, in zone 420.
Subtask 54-52-11-040-063-A ** ON A/C NOT FOR ALL
C. Deactivation of the Thrust Reverser
WARNING: MAKE SURE THAT THE THRUST REVERSER IS LOCKED. IF NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE REVERSER.
   (1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-481-041).
Subtask 54-52-11-040-063-B ** ON A/C NOT FOR ALL
C. Deactivation of the Thrust Reverser
WARNING: MAKE SURE THAT THE THRUST REVERSER IS LOCKED. IF NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE REVERSER.
   (1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-040-012).
4. Procedure
Subtask 54-52-11-020-058-A ** ON A/C NOT FOR ALL
A. Removal of the Access Panels and the Cantilever Cover Assemblies
F Access Panels ** ON A/C NOT FOR ALL
F Access Panels ** ON A/C NOT FOR ALL
   (1) For cantilever cover assemblies 411BT( 421BT) and 411AT( 421AT):
     (a) Remove cantilever cover assemblies 411BT( 421BT) and 411AT( 421AT) (Ref. AMM TASK 54-52-12-300-001).
   (2) For access panels 413AL, 413CL, 413DT, 413AR, 413CR, 423AL, 423CL, 423DT, 423AR and 423CR:
     (a) Hold the access panels (1).
     (b) Remove the screws (3) and the washers (2).
     (c) Remove the access panels (1):