Removal of the Pylon-to-Wing Access Panels and Doors
TASK 54-53-11-000-804-A
Removal of the Pylon-to-Wing Access Panels and Doors
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 54-53-11-941-060-A ** ON A/C NOT FOR ALL
Subtask 54-53-11-020-057-A ** ON A/C NOT FOR ALL
(2) Remove the pylon-to-wing access panel/door (1).
[Rev.10 from 2021]
2026.04.01 02:02:32 UTC
Removal of the Pylon-to-Wing Access Panels and Doors
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
1. Reason for the Job- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 470 | ENGINE 1 AFT PYLON |
| 480 | ENGINE 2 AFT PYLON |
| 413DL, 413ET, 423ET, 424DR, 471AL, 471BL, 471CL, 472AR, 472BR, 481AL, 481BL, 482AR, 482BR, 482CR |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-00-00-860-833-A | Procedure to Prevent Engine Motoring |
| TASK 78-30-00-040-805-A | Deactivation of the Thrust Reverser System for Ground Maintenance |
Subtask 54-53-11-941-060-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
Subtask 54-53-11-040-061-A ** ON A/C NOT FOR ALL (1) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
B. Deactivation of the Thrust Reverser
Subtask 54-53-11-010-060-A ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER IS LOCKED. IF NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE REVERSER.
(1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-040-805). C. Get Access
(1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position:
(a) For the left pylon, in zone 470
(b) For the right pylon, in zone 480.
4. Procedure(1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position:
(a) For the left pylon, in zone 470
(b) For the right pylon, in zone 480.
Subtask 54-53-11-020-057-A ** ON A/C NOT FOR ALL
CAUTION:
WHEN YOU REMOVE THE SCREWS, MAKE SURE THAT YOU RECORD THE CORRECT POSITION OF EACH OF THEM. THE SCREWS HAVE DIFFERENT LENGTHS.
A. Removal of the Pylon-to-Wing Access Panels and Doors NOTE: The procedure is the same for all the panels and the doors:
(1) Remove the screws (2). (2) Remove the pylon-to-wing access panel/door (1).
Pylon-to-Wing Access Panels and Doors