W DOC AIRBUS | AMM A320F

Visual Inspection of the Low Pressure Turbine (LPT) Active Clearance Control (ACC) Valve [CFML]


TASK 75-22-05-210-801-A
Visual Inspection of the Low Pressure Turbine (LPT) Active Clearance Control (ACC) Valve


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
FIN: 4162KS
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 1M(3 FT)
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL, 438AR, 451AL, 452AR
FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL, 448AR, 461AL, 462AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-803-A
Opening of the Fan Cowl Doors
TASK 71-13-00-410-803-A
Closing of the Fan Cowl Doors
TASK 73-21-60-000-813-A
Removal of the HJ8A Engine Wiring Harness
TASK 73-21-60-400-813-A
Installation of the HJ8A Engine Wiring Harness
TASK 75-22-05-000-801-A
Removal of the Low Pressure Turbine Active Clearance Control (LPT ACC) Valve
TASK 75-22-05-400-801-A
Installation of the Low Pressure Turbine Active Clearance Control (LPT ACC) Valve
TASK 78-30-00-040-809-A
Deactivation of the Thrust Reverser System for Ground Maintenance
TASK 78-30-00-440-809-A
Reactivation of the Thrust Reverser System after Ground Maintenance
TASK 78-36-00-010-806-A
Opening of the Thrust Reverser Cowl Doors
TASK 78-36-00-410-806-A
Closing of the Thrust Reverser Cowl Doors
3. Job Set-up
Subtask 75-22-05-941-052-A
A. Safety Precautions
   (1) On the center pedestal, on ENG panel 115VU:
     (a) Make sure that the ENG/MODE selector switch is in the NORM position.
     (b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
     (c) Put WARNING NOTICE(S) in position to tell persons not to operate:
  • The ENG/MODE selector switch
  • The ENG/MASTER 1(2) control switch.
   (2) On the ENG section of maintenance panel 50VU:
     (a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 75-22-05-010-054-A
B. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
   (2) Put an ACCESS PLATFORM 1M(3 FT) in position.
Subtask 75-22-05-040-052-A
C. Deactivation of the Thrust Reverser System for Ground Maintenance
WARNING: YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
   (1) Do the deactivation of the thrust reverser system for ground maintenance (Ref. AMM TASK 78-30-00-040-809).
Subtask 75-22-05-010-055-A
D. Get Access
   (1) Open the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-010-806):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
451AL 452AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
461AL 462AR
4. Procedure
Subtask 75-22-05-210-050-A
A. Do a visual Inspection of the Low Pressure Turbine (LPT) Active Clearance Control (ACC) Valve
INSPECT/CHECK
MAXIMUM SERVICEABLE LIMITS
REMARKS
1.Fuel Leaks
  • It is permitted to have a valve that has a fuel stain, if you do not find drops of fuel.


  • A valve shaft that is wet is permitted, if there are no drops of fuel.


  • A fuel leak that makes drops is not permitted.


  • A fuel leak from the valve housing or shaft is not permitted.
If you find damage or contamination on the fuel fittings replace the LPT ACC valve (Ref. AMM TASK 75-22-05-000-801) and (Ref. AMM TASK 75-22-05-400-801).


If the fuel tubes are not installed correctly or are loose, install and tighten the fuel tube B-nuts (Ref. AMM TASK 75-22-05-400-801).


If the fuel leak continues, replace the LPT ACC valve (Ref. AMM TASK 75-22-05-000-801) and (Ref. AMM TASK 75-22-05-400-801).
2.Inspect for cracks and dents in the LPT ACC valve.
Not serviceable.
Replace the LPT ACC valve (Ref. AMM TASK 75-22-05-000-801) and (Ref. AMM TASK 75-22-05-400-801).
3.Inspect for signs of air leaks
Not serviceable.
Identify the air leakage


Install and tighten the hose clamps and coupling on the LPT ACC valve (Ref. AMM TASK 75-22-05-400-801).
4.Inspect electrical receptacles and connectors on the LPT ACC valve
  • Small damage to electrical connector is acceptable.
If damage to connector prevents correct installation, replace the wiring harness (Ref. AMM TASK 73-21-60-000-813) and (Ref. AMM TASK 73-21-60-400-813).

  • Damage to electrical connector that prevents correct installation is not permitted.
If damage to electrical receptacle prevents correct installation, replace the LPT ACC valve (Ref. AMM TASK 75-22-05-000-801) and (Ref. AMM TASK 75-22-05-400-801).

  • Damage to electrical receptacle that prevents correct installation of the electrical connector is not permitted.
Small damage to the electrical receptacle threads may be repaired until connector can be tightened and can hold torque.
5.Evaluate insulation blanket surrounding the valve
Damage to insulation blanket is not permitted.
If there is damage to the insulation blanket, replace the LPT ACC valve (Ref. AMM TASK 75-22-05-000-801) and (Ref. AMM TASK 75-22-05-400-801).
5. Close-up
Subtask 75-22-05-410-052-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-410-806):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
451AL 452AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
461AL 462AR
Subtask 75-22-05-440-051-A
B. Do the reactivation of the thrust reverser system after ground maintenance (Ref. AMM TASK 78-30-00-440-809).
Subtask 75-22-05-410-053-A
C. Close Access
   (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-803):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
   (2) Remove the access platform(s).
   (3) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 03:14:22 UTC