Removal of the APU Hoist Tool
TASK 49-00-00-080-001-A
Removal of the APU Hoist Tool
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 49-00-00-860-053-A ** ON A/C NOT FOR ALL
Subtask 49-00-00-410-063-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:25:29 UTC
Removal of the APU Hoist Tool
WARNING:
DO NOT TOUCH THE APU UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS WHEN YOU DO THE MAINTENANCE TASK(S).
1. Reason for the JobSelf Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 315AL, 316AR |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 29-10-00-864-001-A | Depressurize the Green Hydraulic System |
| TASK 29-10-00-864-002-A | Depressurize the Yellow Hydraulic System |
| TASK 29-10-00-864-003-A | Depressurize the Blue Hydraulic System |
| TASK 49-11-11-400-003-A | Installation of the Power Plant (APU) (APS 3200) |
| TASK 49-52-41-000-002-A | Removal of the Oil Cooler Outlet Duct (APS 3200) |
| TASK 49-52-41-400-002-A | Installation of the Oil Cooler Outlet Duct (APS 3200) |
| TASK 52-41-00-010-001-A | Open the APU Doors for Access |
| TASK 52-41-00-410-001-A | Close the APU Doors after Access |
| TASK 52-41-21-000-001-A | Removal of APU Access Door 315AL |
| TASK 52-41-21-400-001-A | Installation of APU Access Door 315AL |
Subtask 49-00-00-860-053-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the warning notices are on panel 25VU to tell persons not to start the APU.
(2) Make sure that the ground service network is energized (Ref. AMM TASK 24-41-00-861-002).
(3) Make sure that the hydraulic systems are depressurized (Ref. AMM TASK 29-10-00-864-001), (Ref. AMM TASK 29-10-00-864-002) and (Ref. AMM TASK 29-10-00-864-003).
(4) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE is in position below the access doors 315AL and 316AR.
(5) Make sure that the APU access doors 315AL, 316AR are open (Ref. AMM TASK 52-41-00-010-001) or removed (Ref. AMM TASK 52-41-21-000-001).
(7) Make sure that the the oil-cooler outlet duct is removed (Ref. AMM TASK 49-52-41-000-002).
Subtask 49-00-00-865-083-A ** ON A/C NOT FOR ALL (1) Make sure that the warning notices are on panel 25VU to tell persons not to start the APU.
(2) Make sure that the ground service network is energized (Ref. AMM TASK 24-41-00-861-002).
(3) Make sure that the hydraulic systems are depressurized (Ref. AMM TASK 29-10-00-864-001), (Ref. AMM TASK 29-10-00-864-002) and (Ref. AMM TASK 29-10-00-864-003).
(4) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE is in position below the access doors 315AL and 316AR.
(5) Make sure that the APU access doors 315AL, 316AR are open (Ref. AMM TASK 52-41-00-010-001) or removed (Ref. AMM TASK 52-41-21-000-001).
NOTE: The installation of the A1-91-265 HOIST-MINILIFT is also possible without a removal of the APU access door 315AL, but a removal will make the installation of the A1-91-265 HOIST-MINILIFT easier.
(6) Make sure that the light switch 11LJ is set to on. (7) Make sure that the the oil-cooler outlet duct is removed (Ref. AMM TASK 49-52-41-000-002).
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | APU/APU/CTL | 2KD | L42 |
| 121VU | APU/ECB/SPLY | 1KD | L41 |
| 121VU | APU/FIRE/EXTIG/SQUIB/B | 2WF | L39 |
| 121VU | APU/FIRE/EXTIG/SQUIB/A | 1WF | L38 |
| 121VU | APU/FIRE/LP VALVE/NORM | 4WF | M42 |
| 121VU | APU/FIRE/LP VALVE/STBY | 3WF | M41 |
WARNING:
OBEY THE HOISTING SAFETY PROCEDURES.
MAKE SURE THAT THE HOIST IS ASSEMBLED AND ATTACHED CORRECTLY BEFORE YOU PUT A LOAD ON IT. OBEY THE MANUFACTURER'S INSTRUCTIONS WHEN YOU USE THE HOIST.
IF THE HOIST IS IN AN INCORRECT CONDITION THE LOAD CAN MOVE ACCIDENTALLY AND KILL PERSONS OR CAUSE INJURY.
CAUTION:
MAKE SURE THAT THE THREE ATTACHMENT NUTS ARE INSTALLED AND CORRECTLY TORQUED BEFORE YOU DISCONNECT THE HOIST.
IF YOU DO NOT DO THIS, YOU CAN CAUSE DAMAGE TO THE TIE RODS.
Subtask 49-00-00-080-050-A ** ON A/C NOT FOR ALL A. Removal of the A1-91-265 HOIST-MINILIFT
(1) Make sure that the APU is correctly installed and the APU mount nuts are correctly torqued (Ref. AMM TASK 49-11-11-400-003).
(2) Disconnection of the A1-91-265 HOIST-MINILIFT from the APU
(a) Turn the upper drum shaft of the A1-91-265 HOIST-MINILIFT (10) in a counterclockwise direction until you have removed the tension from the cable (3).
(b) Remove the quick release pin (5) and disconnect the shackle assembly (4) from the adapter of the APU (9).
(c) Disconnect the shackle assembly (4) from the cable (3) of the A1-91-265 HOIST-MINILIFT (10).
(3) Removal of the A1-91-265 HOIST-MINILIFT from the APU compartment
(a) Hold the A1-91-265 HOIST-MINILIFT (10) in position and remove the quick release pin (8) from the bearing assy (7) on the LH side of the APU compartment.
(b) Hold the A1-91-265 HOIST-MINILIFT (10) in position and remove the quick release pin (2) from the APU hoist bracket (1) on the top firewall of the APU compartment.
(c) Remove the A1-91-265 HOIST-MINILIFT (10) from the APU compartment.
(d) Install the quick release pins (2) and (8) temporarily on the A1-91-265 HOIST-MINILIFT (10).
5. Close-up(1) Make sure that the APU is correctly installed and the APU mount nuts are correctly torqued (Ref. AMM TASK 49-11-11-400-003).
(2) Disconnection of the A1-91-265 HOIST-MINILIFT from the APU
(a) Turn the upper drum shaft of the A1-91-265 HOIST-MINILIFT (10) in a counterclockwise direction until you have removed the tension from the cable (3).
(b) Remove the quick release pin (5) and disconnect the shackle assembly (4) from the adapter of the APU (9).
(c) Disconnect the shackle assembly (4) from the cable (3) of the A1-91-265 HOIST-MINILIFT (10).
(3) Removal of the A1-91-265 HOIST-MINILIFT from the APU compartment
(a) Hold the A1-91-265 HOIST-MINILIFT (10) in position and remove the quick release pin (8) from the bearing assy (7) on the LH side of the APU compartment.
(b) Hold the A1-91-265 HOIST-MINILIFT (10) in position and remove the quick release pin (2) from the APU hoist bracket (1) on the top firewall of the APU compartment.
(c) Remove the A1-91-265 HOIST-MINILIFT (10) from the APU compartment.
(d) Install the quick release pins (2) and (8) temporarily on the A1-91-265 HOIST-MINILIFT (10).
Subtask 49-00-00-410-063-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Install the APU oil cooler outlet-duct (Ref. AMM TASK 49-52-41-400-002)
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Close or install the APU access doors 315AL, 316AR (Ref. AMM TASK 52-41-00-410-001) (Ref. AMM TASK 52-41-21-400-001).
(4) Set the light switch 11LJ to the off position.
(5) Remove the access platform(s).
Subtask 49-00-00-865-084-A ** ON A/C NOT FOR ALL (1) Install the APU oil cooler outlet-duct (Ref. AMM TASK 49-52-41-400-002)
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Close or install the APU access doors 315AL, 316AR (Ref. AMM TASK 52-41-00-410-001) (Ref. AMM TASK 52-41-21-400-001).
(4) Set the light switch 11LJ to the off position.
(5) Remove the access platform(s).
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 49-00-00-860-055-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | APU/APU/CTL | 2KD | L42 |
| 121VU | APU/ECB/SPLY | 1KD | L41 |
| 121VU | APU/FIRE/EXTIG/SQUIB/B | 2WF | L39 |
| 121VU | APU/FIRE/EXTIG/SQUIB/A | 1WF | L38 |
| 121VU | APU/FIRE/LP VALVE/NORM | 4WF | M42 |
| 121VU | APU/FIRE/LP VALVE/STBY | 3WF | M41 |
C. Put the aircraft back to its initial configuration.
(1) De-energize the ground service network (Ref. AMM TASK 24-41-00-862-002).
(2) Remove the WARNING NOTICE(S).
(3) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) De-energize the ground service network (Ref. AMM TASK 24-41-00-862-002).
(2) Remove the WARNING NOTICE(S).
(3) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
APU Hoist Minilift Installation