Measurement of the Centre Wire Resistance (CWR) of the OverHeat Detection System (OHDS) Loops
TASK 36-22-00-760-803-A
Measurement of the Centre Wire Resistance (CWR) of the OverHeat Detection System (OHDS) Loops
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 36-22-00-861-058-A ** ON A/C NOT FOR ALL Subtask 36-22-00-010-060-A ** ON A/C NOT FOR ALL
Subtask 36-22-00-760-052-A ** ON A/C NOT FOR ALL
Subtask 36-22-00-865-081-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 12:39:42 UTC
Measurement of the Centre Wire Resistance (CWR) of the OverHeat Detection System (OHDS) Loops
WARNING:
BEFORE YOU INSTALL/REMOVE THE GSE-TOOL, READ THE INSTRUCTIONS IN THE APPLICABLE GSE INSTRUCTION MANUAL. WHILE YOU OPERATE THIS TOOL, CAREFULLY OBEY THEM. IF YOU DO NOT OBEY THE INSTRUCTIONS, INJURY AND/OR DAMAGE CAN OCCUR.
ZONE: 120
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| 20549SI | 1 | LOOP-CONTROLLER |
| 9240SI | 1 | CONTROLLER-LOOP |
| ELC132A | 1 | LCR METERS |
| KRTG36-1032 | 1 | BLEED LOOP GROUND TEST |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 120 | AVIONICS COMPARTMENT |
| 811 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 36-11-34-000-001-A | Removal of the BMC |
| TASK 36-11-34-400-001-A | Installation of the BMC |
| TASK 36-22-00-100-801-A | Clean the Overheat Detection System (OHDS) Connectors and Apply the Electrical Insulating Compound |
| TASK 36-22-00-200-804-A | Wetting Current Procedure |
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
Subtask 36-22-00-861-058-A ** ON A/C NOT FOR ALL Subtask 36-22-00-010-060-A ** ON A/C NOT FOR ALL
B. Get access to the avionics compartment.
(1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at access door 811.
(2) Open access door 811 to get access to the main avionics compartment (Ref. AMM TASK 52-41-00-010-002).
Subtask 36-22-00-865-080-A ** ON A/C NOT FOR ALL (1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at access door 811.
(2) Open access door 811 to get access to the main avionics compartment (Ref. AMM TASK 52-41-00-010-002).
C. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR BLEED/ENG 1/CTL | 3HA1 | D12 |
| 49VU | AIR BLEED/ENG 1/MONG | 2HA1 | D11 |
| 122VU | AIR BLEED/ENG 2/CTL | 3HA2 | Z23 |
| 122VU | AIR BLEED/ENG 2/MONG | 2HA2 | Z22 |
Subtask 36-22-00-760-052-A ** ON A/C NOT FOR ALL
A. Maintenance Procedure
(1) Remove the Bleed Monitoring Computer (BMC) that controls the loop that you will measure (Ref. AMM TASK 36-11-34-000-001).
(3) Connect the test leads of the ELC132A LCR METERS between the pins identified on the specified rack connector(s).
(a) Push the L/C/R key to select the function to measure resistance.
(b) Push the FREQ key to select a test frequency of 1 kHz.
(5) Measure the CWR on the loop between the start pin and the end pin.
(a) Make sure that the measured value is stable.
(6) Make sure that the measured CWR value is lower than the maximum permitted CWR value for the applicable loop.
(a) If the measured CWR value is equal to or more than the maximum permitted CWR value for the loop:
5. Close-up(1) Remove the Bleed Monitoring Computer (BMC) that controls the loop that you will measure (Ref. AMM TASK 36-11-34-000-001).
NOTE: BMC-1 controls left and right WING loops A, loop APU and loop ENG1.
BMC-2 controls left and right WING loops B and loop ENG2.
(2) On the Centre Wire Resistance (CWR) table, do a check of the specified pins for the applicable loop. BMC-2 controls left and right WING loops B and loop ENG2.
(3) Connect the test leads of the ELC132A LCR METERS between the pins identified on the specified rack connector(s).
NOTE: You can also use the 9240SI CONTROLLER-LOOP or the 20549SI LOOP-CONTROLLER or the KRTG36-1032 BLEED LOOP GROUND TEST as an alternative to the ELC132A LCR METERS.
(4) On the ELC132A LCR METERS: (a) Push the L/C/R key to select the function to measure resistance.
(b) Push the FREQ key to select a test frequency of 1 kHz.
(5) Measure the CWR on the loop between the start pin and the end pin.
(a) Make sure that the measured value is stable.
(6) Make sure that the measured CWR value is lower than the maximum permitted CWR value for the applicable loop.
(a) If the measured CWR value is equal to or more than the maximum permitted CWR value for the loop:
- Do the wetting current procedure (Ref. AMM TASK 36-22-00-200-804).
- Clean the OverHeat Detection System (OHDS) connectors and apply the electrical insulating compound (Ref. AMM TASK 36-22-00-100-801).
Subtask 36-22-00-865-081-A ** ON A/C NOT FOR ALL
A. Remove the safety clips and tags and close these circuit breakers in this sequence:
Subtask 36-22-00-410-062-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR BLEED/ENG 2/CTL | 3HA2 | Z23 |
| 49VU | AIR BLEED/ENG 1/MONG | 2HA1 | D11 |
| 49VU | AIR BLEED/ENG 1/CTL | 3HA1 | D12 |
| 122VU | AIR BLEED/ENG 2/MONG | 2HA2 | Z22 |
B. Close Access
(1) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Close access door 811 (Ref. AMM TASK 52-41-00-410-002).
(4) Remove the access platform(s).
Subtask 36-22-00-860-078-A ** ON A/C NOT FOR ALL (1) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Close access door 811 (Ref. AMM TASK 52-41-00-410-002).
(4) Remove the access platform(s).
C. Aircraft Maintenance Configuration
(1) Put the aircraft back to its initial configuration.
Subtask 36-22-00-862-058-A ** ON A/C NOT FOR ALL (1) Put the aircraft back to its initial configuration.
CWR Connections