Installation of the BMC
TASK 36-11-34-400-001-A
Installation of the BMC
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 36-11-34-860-051-A
Subtask 36-11-34-420-050-A
Subtask 36-11-34-410-050-A
[Rev.10 from 2021]
2026.04.01 01:08:59 UTC
Installation of the BMC
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 121 | AVIONICS COMPARTMENT |
| 122 | AVIONICS COMPARTMENT |
| 811 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 36-11-00-610-801-A | Uploading of the Bleed Monitoring Computer (BMC) Data |
| TASK 36-11-00-740-001-A | BITE Test of the BMC 1(2) |
| TASK 36-11-00-740-802-A | BITE Test of the Engine Bleed Air System (EBAS) (System Test) |
Subtask 36-11-34-860-051-A
A. Aircraft Maintenance Configuration
(1) Make sure that the ground service network is energized (Ref. AMM TASK 24-42-00-861-001).
Subtask 36-11-34-010-051-A (1) Make sure that the ground service network is energized (Ref. AMM TASK 24-42-00-861-001).
B. Get Access
(1) Make sure that the ACCESS PLATFORM 2M (6 FT) is in position at the access door 811.
(2) Make sure that the access door 811 is open.
Subtask 36-11-34-865-051-A (1) Make sure that the ACCESS PLATFORM 2M (6 FT) is in position at the access door 811.
(2) Make sure that the access door 811 is open.
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 1HA1 (BMC1) | |||
| 49VU | AIR BLEED/ENG 1/CTL | 3HA1 | D12 |
| 49VU | AIR BLEED/ENG 1/MONG | 2HA1 | D11 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR BLEED/ENG 1/CTL | 2HA1 | D11 |
| 122VU | AIR BLEED/ENG 1/MONG | 3HA1 | Z23 |
| FOR FIN: 1HA2 (BMC2) | |||
| 49VU | AIR BLEED/ENG 2/MONG | 3HA2 | D12 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR BLEED/ENG 2/CTL | 3HA2 | Z23 |
| 122VU | AIR BLEED/ENG 2/MONG | 2HA2 | Z22 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR BLEED/ENG 2/CTL | 2HA2 | Z22 |
Subtask 36-11-34-420-050-A
A. Installation of the BMC
(1) Clean the component interface and/or the adjacent area.
(2) Remove the CAP-BLANKING from each electrical connector and receptacle.
(3) Make sure that all the electrical connections are clean and in the correct condition.
(4) Install the BMC (1) on its rack (3).
(5) Push the BMC (1) on its rack (3) to connect the electrical connectors (2).
(6) Engage the nut (4) on the lug (5) and tighten.
Subtask 36-11-34-865-052-A (1) Clean the component interface and/or the adjacent area.
(2) Remove the CAP-BLANKING from each electrical connector and receptacle.
(3) Make sure that all the electrical connections are clean and in the correct condition.
(4) Install the BMC (1) on its rack (3).
(5) Push the BMC (1) on its rack (3) to connect the electrical connectors (2).
(6) Engage the nut (4) on the lug (5) and tighten.
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 36-11-34-970-050-B ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 1HA1 (BMC1) | |||
| 49VU | AIR BLEED/ENG 1/CTL | 3HA1 | D12 |
| 49VU | AIR BLEED/ENG 1/MONG | 2HA1 | D11 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR BLEED/ENG 1/CTL | 2HA1 | D11 |
| 122VU | AIR BLEED/ENG 1/MONG | 3HA1 | Z23 |
| FOR FIN: 1HA2 (BMC2) | |||
| 49VU | AIR BLEED/ENG 2/MONG | 3HA2 | D12 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR BLEED/ENG 2/CTL | 3HA2 | Z23 |
| 122VU | AIR BLEED/ENG 2/MONG | 2HA2 | Z22 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR BLEED/ENG 2/CTL | 2HA2 | Z22 |
C. Do a check of the configuration of the BMC that you installed and, if necessary, upload the applicable software (Ref. AMM TASK 36-11-00-610-801).
Subtask 36-11-34-710-050-A ** ON A/C NOT FOR ALL Subtask 36-11-34-710-050-B ** ON A/C NOT FOR ALL D. Do the BITE test of the Engine Bleed Air System (EBAS) (System Test) (Ref. AMM TASK 36-11-00-740-802).
5. Close-upSubtask 36-11-34-410-050-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 811.
(3) Remove the access platform(s).
Subtask 36-11-34-862-050-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 811.
(3) Remove the access platform(s).
Bleed Monitoring Computer (BMC)