36-12-00-615-801-A [10] Decontamination of the Bleed-Air Ducting System Disconnected at APU Load-Compressor Valve with Engine 1 Bleed Pressure
36-12-00-615-801-A-01 [10] Decontamination of the Bleed-Air Ducting System Disconnected at APU Load-Compressor Valve with Engine 2 Bleed Pressure
36-12-00-615-802-A [10] Decontamination of the Bleed-Air Ducting System Disconnected at APU Load-Compressor Valve with Engine 1 Bleed Pressure
36-12-00-615-802-A-01 [10] Decontamination of the Bleed-Air Ducting System Disconnected at APU Load-Compressor Valve with Engine 2 Bleed Pressure
36-12-00-615-802-A-02 [10] Decontamination of the Bleed-Air Ducting System Disconnected at APU Load-Compressor Valve with Engine 2 Bleed Pressure
36-12-00-615-802-A-03 [10] Decontamination of the Bleed-Air Ducting System Disconnected at APU Load-Compressor Valve with Engine 1 Bleed Pressure
36-12-00-615-803-A [10] Decontamination of the Bleed-Air Ducting System Disconnected at the APU Load-Compressor Valve with Engine 1 Bleed Pressure
36-12-00-615-803-A-01 [10] Decontamination of the Bleed-Air Ducting System Disconnected at the APU Load-Compressor Valve with Engine 2 Bleed Pressure
36-12-00-615-804-A [10] Decontamination of the Bleed-Air Ducting System Disconnected at Pressure Regulating Valve (PRV) (4000HA1,4000HA2) with the APU Bleed Pressure
36-12-00-615-804-A-01 [10] Decontamination of the Bleed-Air Ducting System Disconnected at Pressure Regulating Valve (PRV) (4000HA1) with the APU Bleed Pressure
36-12-00-615-804-A-02 [10] Decontamination of the Bleed-Air Ducting System Disconnected at Pressure Regulating Valve (PRV) (4000HA2) with the APU Bleed Pressure
36-12-00-615-805-A [10] Decontamination of the Bleed-Air Ducting System Disconnected at Pressure Regulating Valve (PRV) (4000HA1, 4000HA2) with the APU Bleed Pressure
36-12-00-615-805-A-01 [10] Decontamination of the Bleed-Air Ducting System Disconnected at Pressure Regulating Valve (PRV) (4000HA1) with the APU Bleed Pressure
36-12-00-615-805-A-02 [10] Decontamination of the Bleed-Air Ducting System Disconnected at Pressure Regulating Valve (PRV) (4000HA2) with the APU Bleed Pressure
36-12-00-615-806-A [10] Decontamination of the Bleed-Air Ducting System disconnected at the Pressure Regulating Valve (PRV) (4000HA1, 4000HA2) with the APU Bleed Pressure
36-12-00-615-806-A-01 [10] Decontamination of the Bleed-Air Ducting System disconnected at the Pressure Regulating Valve (PRV) (4000HA1) with the APU Bleed Pressure
36-12-00-615-806-A-02 [10] Decontamination of the Bleed-Air Ducting System disconnected at the Pressure Regulating Valve (PRV) (4000HA2) with the APU Bleed Pressure
36-12-00-615-807-A [10] Decontamination of the Bleed-Air Ducting System Disconnected at HP Ground Connector with the APU Bleed Pressure
36-12-00-615-808-A [10] Decontamination of the Bleed-Air Ducting System Disconnected at HP Ground Connector with the APU Bleed Pressure
36-12-00-615-809-A [10] Decontamination of the Bleed-Air Ducting System through HP Ground Connector with the APU Bleed Pressure
36-12-00-710-001-A [10] Operational Test of the APU Bleed Air Supply and Crossbleed Systems
36-12-00-790-002-A [10] Perform Leak Check on APU Bleed Air Ducting (Upstream the APU Bleed Check Valve)
36-12-00-790-003-A [10] Leak Check of Bleed Air Ducting in the Fuselage Area between the APU Bleed Check Valve, Air Conditioning Pack and Wing/Fuselage Connection