Replacement of the Fluorescent Tube in the Ceiling Panel
TASK 33-21-11-960-001-A
Replacement of the Fluorescent Tube in the Ceiling Panel
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 33-21-11-861-052-A ** ON A/C NOT FOR ALL
Subtask 33-21-11-960-050-A ** ON A/C NOT FOR ALL
Subtask 33-21-11-410-053-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:53:18 UTC
Replacement of the Fluorescent Tube in the Ceiling Panel
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | GLOVES - COTTON, LINT-FREE, CLEAN |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | 1 | STEPLADDER 1.0 M (3.3 FT) |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 23-73-00-861-001-A | Energize the Cabin Intercommunication Data System (CIDS) |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 25-23-42-000-001-A | Removal of the Ceiling Panels - Forward Utility Area |
| TASK 25-23-42-000-002-A | Removal of the Ceiling Panels - Aft Utility Area |
| TASK 25-23-42-400-001-A | Installation of the Ceiling Panels - Forward Utility Area |
| TASK 25-23-42-400-002-A | Installation of the Ceiling Panels - Aft Utility Area |
| TASK 25-23-48-000-001-A | Removal of the Cove Light Panel |
| TASK 25-23-48-400-001-A | Installation of the Cove Light Panel |
Subtask 33-21-11-861-052-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 33-21-11-865-058-A ** ON A/C NOT FOR ALL (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
NOTE: The table that follows shows you all circuit breakers for the ballast units. If you open all the circuit breakers, the cabin becomes dark.
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 33-21-11-010-052-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | CAB LIGHT PWR-CEILING-AFT | 307LG | H08 |
| 2000VU | CAB LIGHT PWR-CEILING-AFT | 304LG | H07 |
| 2000VU | CAB LIGHT PWR-CEILING-FWD | 306LG | H06 |
| 2000VU | CAB LIGHT PWR-CEILING-FWD | 305LG | H05 |
| 2000VU | CAB LIGHT PWR-WINDOW-AFT | 302LG | H04 |
| 2000VU | CAB LIGHT PWR-WINDOW-AFT | 301LG | H03 |
| 2000VU | CAB LIGHT PWR-WINDOW-FWD | 303LG | H02 |
| 2000VU | CAB LIGHT PWR-WINDOW-FWD | 300LG | H01 |
C. Get Access
(1) For the aisle light unit:
(a) Put the STEPLADDER 1.0 M (3.3 FT) below the related ceiling panel.
(b) Release the quick-release fasteners (4) and remove the light cover (5).
(2) For the window light unit:
(a) Remove the related cove light panel (Ref. AMM TASK 25-23-48-000-001).
(3) For the entrance light unit:
(a) Put the STEPLADDER 1.0 M (3.3 FT) below the related ceiling panel.
(b) Remove the related ceiling panel (Ref. AMM TASK 25-23-42-000-001) (Ref. AMM TASK 25-23-42-000-002).
4. Procedure(1) For the aisle light unit:
(a) Put the STEPLADDER 1.0 M (3.3 FT) below the related ceiling panel.
(b) Release the quick-release fasteners (4) and remove the light cover (5).
(2) For the window light unit:
(a) Remove the related cove light panel (Ref. AMM TASK 25-23-48-000-001).
(3) For the entrance light unit:
(a) Put the STEPLADDER 1.0 M (3.3 FT) below the related ceiling panel.
(b) Remove the related ceiling panel (Ref. AMM TASK 25-23-42-000-001) (Ref. AMM TASK 25-23-42-000-002).
Subtask 33-21-11-960-050-A ** ON A/C NOT FOR ALL
A. Replacement of the Fluorescent Tube
(3) Remove and discard the fluorescent tube (1).
(4) Install the new fluorescent tube (1) into the lampholder (3). Make sure that you hear a click from each holder when you push the fluorescent tube (1) into the lampholder (3).
Subtask 33-21-11-865-059-A ** ON A/C NOT FOR ALL NOTE: The procedure is the same for all fluorescent tubes in the aisle light strips, window light strips and entrance lights (if installed).
(1) Use GLOVES - COTTON, LINT-FREE, CLEAN for the replacement of the fluorescent tube (1). CAUTION:
DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE CLOTH.
(2) Hold the fluorescent tube (1) and push the button (2) at the end of the lampholder (3) to remove the fluorescent tube (1). (3) Remove and discard the fluorescent tube (1).
(4) Install the new fluorescent tube (1) into the lampholder (3). Make sure that you hear a click from each holder when you push the fluorescent tube (1) into the lampholder (3).
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 33-21-11-860-053-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | CAB LIGHT PWR-CEILING-AFT | 307LG | H08 |
| 2000VU | CAB LIGHT PWR-CEILING-AFT | 304LG | H07 |
| 2000VU | CAB LIGHT PWR-CEILING-FWD | 306LG | H06 |
| 2000VU | CAB LIGHT PWR-CEILING-FWD | 305LG | H05 |
| 2000VU | CAB LIGHT PWR-WINDOW-AFT | 302LG | H04 |
| 2000VU | CAB LIGHT PWR-WINDOW-AFT | 301LG | H03 |
| 2000VU | CAB LIGHT PWR-WINDOW-FWD | 303LG | H02 |
| 2000VU | CAB LIGHT PWR-WINDOW-FWD | 300LG | H01 |
C. Aircraft Maintenance Configuration
(1) Make sure that the Cabin Intercommunication Data System (CIDS) is energized
(Ref. AMM TASK 23-73-00-861-001).
Subtask 33-21-11-710-052-A ** ON A/C NOT FOR ALL (1) Make sure that the Cabin Intercommunication Data System (CIDS) is energized
(Ref. AMM TASK 23-73-00-861-001).
D. Operational Test
(1) Do this test of the entrance-Lights, window-lights and ceiling-lights:
5. Close-up(1) Do this test of the entrance-Lights, window-lights and ceiling-lights:
| ACTION | RESULT |
|---|---|
| 1.For the entrance lighting: | |
| On Flight Attendant Panel (FAP) 120RH: | On FAP 120RH: |
|
|
|
|
| | In the cabin:
|
| | On FAP 120RH: |
|
|
| | In the cabin:
|
| | On FAP 120RH: |
|
|
| | In the cabin:
|
| | On FAP 120RH: |
|
|
| | In the cabin:
|
| 2.For the window or ceiling lighting: | |
| On FAP 120RH: | On FAP 120RH: |
|
|
| | In the cabin:
|
| | On FAP 120RH: |
|
|
| | In the cabin:
|
| | On FAP 120RH: |
|
|
| | In the cabin:
|
| | On FAP 120RH: |
|
|
| | In the cabin:
|
Subtask 33-21-11-410-053-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the related panel:
(a) For the aisle light unit:
1 Put the STEPLADDER 1.0 M (3.3 FT) under related ceiling panel.
2 Install the light cover (5) with the quick-release fasteners (4).
(b) For the window light unit:
1 Install the related cove light panel (Ref. AMM TASK 25-23-48-400-001).
(c) For the entrance light unit:
1 Put the STEPLADDER 1.0 M (3.3 FT) below the related ceiling panel.
2 Install the related ceiling panel (Ref. AMM TASK 25-23-42-400-001) (Ref. AMM TASK 25-23-42-400-002).
(3) Remove the STEPLADDER 1.0 M (3.3 FT).
Subtask 33-21-11-862-052-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the related panel:
(a) For the aisle light unit:
1 Put the STEPLADDER 1.0 M (3.3 FT) under related ceiling panel.
2 Install the light cover (5) with the quick-release fasteners (4).
(b) For the window light unit:
1 Install the related cove light panel (Ref. AMM TASK 25-23-48-400-001).
(c) For the entrance light unit:
1 Put the STEPLADDER 1.0 M (3.3 FT) below the related ceiling panel.
2 Install the related ceiling panel (Ref. AMM TASK 25-23-42-400-001) (Ref. AMM TASK 25-23-42-400-002).
(3) Remove the STEPLADDER 1.0 M (3.3 FT).
B. Put the aircraft back to its initial configuration.
(1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
Replacement of the Fluorescent Tube in the Ceiling Panel