Installation of the Removable SIM Module (RSM) and the SIM Module I/O Cards (SMIO) of the WGL-DAR
TASK 31-36-00-400-803-A
Installation of the Removable SIM Module (RSM) and the SIM Module I/O Cards (SMIO) of the WGL-DAR
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 31-36-00-861-086-A ** ON A/C NOT FOR ALL
Subtask 31-36-00-420-059-A ** ON A/C NOT FOR ALL
Subtask 31-36-00-410-093-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 08:36:18 UTC
Installation of the Removable SIM Module (RSM) and the SIM Module I/O Cards (SMIO) of the WGL-DAR
CAUTION:
OBEY THESE PRECAUTIONS TO PREVENT ELECTROSTATIC DISCHARGE (ESD) DAMAGE TO THE COMPONENTS:
- STAY ON A CONDUCTIVE SURFACE THAT IS ELECTRICALLY GROUNDED.
- USE A CONDUCTIVE WRIST-STRAP THAT IS ELECTRICALLY GROUNDED. (CONNECTED TO A BONDING-POINT NEAR THE WORK AREA).
- BEFORE YOU USE THE TOOLS, MOMENTARILY HOLD THEM AGAINST AN ELECTRICAL GROUND TO RELEASE STATIC ELECTRICITY.
CAUTION:
BEFORE YOU REMOVE OR INSTALL THE REMOVABLE SIM MODULE, MAKE SURE THAT THE WGL DAR IS DE-ENERGIZED. IF YOU DO NOT OBEY THIS INSTRUCTION, DAMAGE TO THE EQUIPMENT CAN OCCUR.
CAUTION:
INSTALL THE SIM CARDS VERY CAREFULLY AND MAKE SURE THAT YOU DO NOT CAUSE DAMAGE TO THEIR METAL CONTACTS. THIS WILL HELP TO PREVENT DAMAGE TO OTHER COMPONENTS.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 121 | AVIONICS COMPARTMENT |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 31-36-00-740-017-A | Test of the Wireless Ground Link-Digital AIDS Recorder (WGL-DAR) |
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
| TASK 31-36-00-00-02 | AIDS INTERCONNECTION (DMU, DAR) - DESCRIPTION AND OPERATION |
Subtask 31-36-00-861-086-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 31-36-00-010-093-A ** ON A/C NOT FOR ALL (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
B. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below access door 824.
(2) Open access door 824 (Ref. AMM TASK 52-41-00-010-002).
(3) For the location of the WGL-DAR, refer to paragraph Component Location (Ref. AMM D/O 31-36-00-00).
Subtask 31-36-00-865-166-A ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below access door 824.
(2) Open access door 824 (Ref. AMM TASK 52-41-00-010-002).
(3) For the location of the WGL-DAR, refer to paragraph Component Location (Ref. AMM D/O 31-36-00-00).
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | RCDR/ACCLRM | 9TU | K18 |
| 121VU | AIDS & RCDR/FDIMU | 5TV | K15 |
Subtask 31-36-00-420-059-A ** ON A/C NOT FOR ALL
A. Installation of the Removable SIM Module (RSM)
(1) If removed, install the new SIM cards (2).
(3) Install and secure the screws (3).
(4) Make sure that the arrow of the RSM (1) points up.
(5) Hold tightly the handle of the RSM (1). Push the RSM (1) into the slot.
(6) Move down the top clip and move up the bottom clip to safety the RSM (1).
(7) Turn the thumbscrew clockwise by hand to safety the access door.
Subtask 31-36-00-865-167-A ** ON A/C NOT FOR ALL (1) If removed, install the new SIM cards (2).
NOTE: If the SIM cards (2) are replaced, a new OPC (configuration) file must be installed. Contact the vendor customer services for more information. This will help to prevent malfunction of the equipment.
NOTE: It is recommended to record the correct position of the SIM cards (2). You must install the new SIM cards (2) in same position as before removal.
(2) Put the shield (4) in position. (3) Install and secure the screws (3).
(4) Make sure that the arrow of the RSM (1) points up.
(5) Hold tightly the handle of the RSM (1). Push the RSM (1) into the slot.
(6) Move down the top clip and move up the bottom clip to safety the RSM (1).
(7) Turn the thumbscrew clockwise by hand to safety the access door.
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 31-36-00-710-135-A ** ON A/C NOT FOR ALL 5. Close-up| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | RCDR/ACCLRM | 9TU | K18 |
| 121VU | AIDS & RCDR/FDIMU | 5TV | K15 |
Subtask 31-36-00-410-093-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close access door 824 (Ref. AMM TASK 52-41-00-410-002).
(3) Remove the access platform(s).
Subtask 31-36-00-862-088-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close access door 824 (Ref. AMM TASK 52-41-00-410-002).
(3) Remove the access platform(s).
B. Aircraft Maintenance Configuration
(1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
Removable SIM Module (RSM) and the SIM Module I/O Cards (SMIO) of the WGL-DAR