Update of the Aircraft Tail Number in the Wireless Ground Link-Quick Access Recorder (WGL-QAR)
TASK 31-33-00-710-018-A
Update of the Aircraft Tail Number in the Wireless Ground Link-Quick Access Recorder (WGL-QAR)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 31-33-00-861-067-A ** ON A/C NOT FOR ALL Subtask 31-33-00-010-063-C ** ON A/C NOT FOR ALL
Subtask 31-33-00-710-087-C ** ON A/C NOT FOR ALL
Subtask 31-33-00-410-063-C ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 08:31:47 UTC
Update of the Aircraft Tail Number in the Wireless Ground Link-Quick Access Recorder (WGL-QAR)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 120 | AVIONICS COMPARTMENT |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
| TASK 31-33-00-00 | DIGITAL FLIGHT DATA RECORDING SYSTEM (DFDRS) - INTERCONNECTION - DESCRIPTION AND OPERATION |
Subtask 31-33-00-861-067-A ** ON A/C NOT FOR ALL Subtask 31-33-00-010-063-C ** ON A/C NOT FOR ALL
B. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at access door 824.
(2) Open access door 824 (Ref. AMM TASK 52-41-00-010-002).
(3) For the location of the WGL-QAR, refer to paragraph Component Location (Ref. AMM D/O 31-33-00-00).
Subtask 31-33-00-865-082-A ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at access door 824.
(2) Open access door 824 (Ref. AMM TASK 52-41-00-010-002).
(3) For the location of the WGL-QAR, refer to paragraph Component Location (Ref. AMM D/O 31-33-00-00).
C. Make sure that this(these) circuit breaker(s) is(are) closed:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | RCDR/ACCLRM | 9TU | K18 |
| 121VU | AIDS & RCDR/QAR | 14TU | K17 |
| 121VU | AIDS & RCDR/FDIMU | 5TV | K15 |
Subtask 31-33-00-710-087-C ** ON A/C NOT FOR ALL
A. Update of the Aircraft Tail Number in the WGL-QAR
5. Close-up| ACTION | RESULT |
|---|---|
| On the WGL-QAR Front Panel: | On the WGL-QAR Display: |
|
|
|
|
|
|
|
|
|
|
| NOTE: The Tail Number field is empty. In this condition, the underscore flashes in the first position. |
|
|
|
|
|
|
|
|
NOTE: All characters that follow the <SPACE> character get erased. |
|
|
NOTE: The reboot procedure is completed in approximately 5 minutes. After reboot, the WGL-QAR is prepared for operation with the new tail number. If you want to discard the changes, after reboot push the - button. |
Subtask 31-33-00-410-063-C ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close access door 824 (Ref. AMM TASK 52-41-00-410-002).
(3) Remove the access platform(s).
Subtask 31-33-00-862-067-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close access door 824 (Ref. AMM TASK 52-41-00-410-002).
(3) Remove the access platform(s).