W DOC AIRBUS | AMM A320F

Removal of the Anti-Ice Duct


TASK 30-11-42-000-001-A
Removal of the Anti-Ice Duct


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY BARRIER(S)
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
98D27803000000
1
LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
522BT, 522CB, 622BT, 622CB
522YB, 622YB
522AB, 622AB
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 27-80-00-866-004-A
Extending the Slats on the Ground
TASK 30-11-41-000-001-A
Removal of the Telescopic Duct
TASK 49-00-00-860-006-A
APU Shutdown by External Power
TASK 49-00-00-860-006-A-01
APU Shutdown by Batteries
TASK 49-00-00-860-009-A
APU Shutdown by External Power (131-9(A))
TASK 49-00-00-860-009-A-01
APU Shutdown by Batteries (131-9(A))
TASK 57-41-37-000-004-A
Removal of the Pressure Relief Panels
3. Job Set-up
Subtask 30-11-42-861-050-A
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002) or (Ref. AMM TASK 24-41-00-861-002).
Subtask 30-11-42-941-050-A
B. Safety Precautions
   (1) On the flap and slat control lever, on panel 114VU, install the 98D27803000000 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION.
   (2) Put the WARNING NOTICE(S) in positions that follow, before you start the work on the ice protection system:
  • On the high-pressure ground-power connections, to tell persons not to pressurize the pneumatic system
  • In the cockpit, to tell persons not to operate the engines or the APU control switches
  • On panel 30VU, to tell persons not to pressurize the bleed-air system
  • On panel 114VU, to tell persons not to operate the slat controls.
   (3) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
Subtask 30-11-42-866-050-A
C. Extend the Slats
   (1) Extend the slats fully (Ref. AMM TASK 27-80-00-866-004).
Subtask 30-11-42-865-050-A
D. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/SLT/CTL AND MONG/SYS15CVB06
** ON A/C ALL
49VUANTI ICE/WING/CTL2DLC02
49VUANTI ICE/WING/MONG1DLC01
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/SLT/CTL AND MONG/SYS15CVB01
** ON A/C ALL
121VUFLIGHT CONTROLS/SLT/CTL/SYS27CVR21
Subtask 30-11-42-010-050-A ** ON A/C NOT FOR ALL
E. Get Access
   (1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in the applicable position:
  • For the LH wing, below zone 510
  • For the RH wing, below zone 610.
   (2) Remove the applicable access panels (Ref. AMM TASK 57-41-37-000-004):
     (a) For the LH wing:
     (b) For the RH wing:
Subtask 30-11-42-010-050-B ** ON A/C NOT FOR ALL
E. Get Access
   (1) Put an ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in the applicable position:
  • For the LH wing, below zone 510.
  • For the RH wing, below zone 610.
   (2) Remove the applicable access panels (Ref. AMM TASK 57-41-37-000-004):
4. Procedure
Subtask 30-11-42-020-050-B
A. Removal of the Anti-Ice Ducts

NOTE: Put CAP - BLANKING on the ends of the ducts, immediately after you remove them.
   (1) If you use the APU to energize the aircraft electrical circuits, stop the APU:
WARNING: MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
   (2) Make sure that you wait for a minimum of 5 minutes until there is no pressure in the bleed-air duct system.
WARNING: DO NOT TOUCH THE UNIT UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS WHEN YOU DO THE MAINTENANCE TASK(S).
   (3) Make sure that the temperature of the bleed-air duct system is in the ambient condition.
   (4) To remove the duct (24):
     (a) Remove and discard the braided wire from the insulation muff (1) and then remove the insulation muff (1).
     (b) Remove the nut (25), the washer (26) and the screw (28), to disconnect the ends of the bonding straps (27) and (23).
     (c) Hold the duct (24) and remove the clamp (22).
     (d) Turn the duct (24) axially in relation to the anti-ice valve and carefully remove it from the duct (3).
     (e) Remove and discard the seal (2).
   (5) To remove the duct (3):
     (a) Remove and discard the braided wire from the insulation muff (9) and then remove the insulation muff (9).
     (b) Remove the nut (13), the washers (14) and (17) and the screw (18) to disconnect the end of the bonding strap (16).
     (c) Remove the nut (15), the washer (19), the screw (21) and the bonding strap (20).
     (d) Remove the nut (12), the bolt (10) and the cradle (4).
     (e) Remove the bolts (5) and (11), the washers (6) and the cradle (7).
     (f) Move the blast tube (8) inboard, to the approximate center of the duct (3).
     (g) Carefully remove the duct (3) together with the blast tube (8) from the duct (30).
     (h) Remove and discard the seal (29).
     (i) Remove the blast tube (8) from the duct (3).
   (6) To remove the duct (30):
     (a) Remove and discard the braided wire from the insulation muff (40) and then remove the insulation muff (40).
     (b) Remove the nut (32), the washer (33) and the screw (35), to disconnect the end of the bonding strap (34).
     (c) Remove the nut (36), the washer (37), the screw (39) and the bonding strap (38).
     (d) To remove the lower part of the intermediate rib:
  • Remove the nuts (71), (58) and (66), the bolts (72), (69) and (70) and the bracket (73).
  • Remove the nuts (67), the support washer (56), the bolts (57) and the top bracket (55).
  • Remove the nuts (63), the bolts (60), the lower bracket (59) and the support bracket (65).
  • Remove the nuts (61) and (68), the bolts (64) and (74) and the center rib (75) from the support ribs (54) and (62).
     (e) Remove the duct (30).
     (f) Remove and discard the seal (31).
   (7) To remove the duct (46):
     (a) Remove and discard the braided wire from the insulation muff (76) and then remove the insulation muff (76).
     (b) Remove the nut (48), the washer (45) and the screw (44), to disconnect the end of the bonding strap (34).
     (c) Remove the nut (53), the bolt (50) and the cradle (52).
     (d) Remove the bolts (41) and (51), the washers (42) and the cradle (43).
     (e) Move the blast tube (49) inboard.
     (f) Hold the duct (46) and remove the clamp (47) and then the duct (46).
   (8) To remove the duct (77):
     (a) Remove and discard the braided wires from the insulation muffs (76) and (82) and then remove the insulation muffs (76) and (82).
     (b) Remove the nut (83), the washer (84) and the screw (78), to disconnect the ends of the bonding straps (79) and (80).
     (c) Hold the duct (77) and remove the clamp (47).
     (d) Turn the duct (77) axially in relation to the duct (46) and carefully remove it from the duct box (87).
     (e) Remove and discard the seal (81).
   (9) To remove the duct box (87):
NOTE: It is necessary to remove the duct (77) before you remove the duct box (87).
     (a) Remove the telescopic duct (Ref. AMM TASK 30-11-41-000-001).
     (b) Remove the nut (90), the washer (91), the screw (93) and the bonding strap (92).
WARNING: USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
     (c) Remove and discard the lockwire from the bolts (85) and (89).
     (d) Hold the duct box (87) and remove the bolts (85) and (89) and the washers (86) and (88).
     (e) Remove the duct box (87).
[Rev.10 from 2021] 2026.04.01 00:28:25 UTC