To Drain the Remaining Fuel from the Additional Center Tank (ACT)
TASK 28-25-00-650-005-A
To Drain the Remaining Fuel from the Additional Center Tank (ACT)
Self Explanatory
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 28-25-00-941-084-A ** ON A/C NOT FOR ALL
Subtask 28-25-00-680-052-A ** ON A/C NOT FOR ALL
Subtask 28-25-00-080-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:06:05 UTC
To Drain the Remaining Fuel from the Additional Center Tank (ACT)
WARNING:
OBEY THE FUEL SAFETY PROCEDURES.
WARNING:
BE CAREFUL NOT TO GET AIRCRAFT FUEL IN YOUR MOUTH OR IN YOUR EYES.
IF YOU GET FUEL ON YOUR SKIN OR ON YOUR CLOTHES, FLUSH IT IMMEDIATELY WITH WATER.
IF NECESSARY, GET MEDICAL HELP.
AIRCRAFT FUEL IS POISONOUS.
WARNING:
DO NOT GET YOUR CLOTHES SOAKED WITH FUEL.
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
MAKE SURE THE AREA AROUND THE AIRCRAFT IS SAFE BEFORE YOU START THE REFUEL/DEFUEL PROCEDURE. IN THE SAFETY AREA, DO NOT:
1. Reason for the Job- SMOKE
- MAKE SPARKS OR FIRE
- USE ANY EQUIPMENT WHICH IS NOT APPROVED FOR REFUEL/DEFUEL PROCEDURES.
Self Explanatory
NOTE: If you do this procedure regularly it can prevent microbiological contamination of the fuel tanks.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | 2 | ADAPTER 0,75 IN (19,05 MM) - SQUARE DRIVE |
| No specific | AR | CONTAINER 30 L(8 USGAL) |
| No specific | 2 | GAGE 5 BAR (75 PSI) - PRESSURE |
| No specific | 1 | GROUND PRESSURE GENERATOR - 0 TO 2 BAR (0 TO 30 PSI) |
| No specific | 2 | PROBE - NON METALLIC, FLEXIBLE |
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | 2 | STEPLADDER 0.5 M (1.6 FT) |
| No specific | AR | WARNING NOTICE(S) |
| 98D28108293000 | AR | ADAPTER-WATER DRAIN, ADDITIONAL CENTER TANK |
| 98D28108293002 | AR | ADAPTER-WATER DRAIN, ADDITIONAL CENTER TANK |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 130 | FWD CARGO COMPT AFT BULKHEAD OF AVNCS COMPT TO FWD PRESSURE BULKHEAD OF WING CENTER BOX |
| 150 | AFT CARGO COMPARTMENT FWD PRESS BULKHEAD TO AFT BULKHEAD OF AFT CARGO COMPARTMENT |
| 160 | BULK CARGO COMPARTMENT AFT BULKHEAD OF AFT CARGO COMPARTMENT TO AFT BULKHEAD OF BULK CARGO COMPARTMENT |
| 151NC, 153AZ, 192MB, 197AB, 197GB, 826 | |
| 154AZ, 154BR, 198QB |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 25-55-11-000-002-A | Removal of the Ceiling Panels in the Aft Cargo-Compartment - FR47/FR59 |
| TASK 25-55-11-400-002-A | Installation of the Ceiling Panels in the Aft Cargo-Compartment - FR47/FR59 |
| TASK 28-00-00-910-001-A | Fuel Safety Procedures |
| TASK 28-25-00-650-001-A | Pressure Defuel |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-002-A | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 53-35-13-000-001-A | Removal of the Belly Fairing Access Panels |
| TASK 53-35-13-400-001-A | Installation of the Belly Fairing Access Panels |
Subtask 28-25-00-941-084-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Obey the fuel safety procedures (Ref. AMM TASK 28-00-00-910-001).
(2) Put a WARNING NOTICE(S) on the panels that follow, to tell persons not to operate the refuel/defuel system:
Subtask 28-25-00-860-069-A ** ON A/C NOT FOR ALL (1) Obey the fuel safety procedures (Ref. AMM TASK 28-00-00-910-001).
(2) Put a WARNING NOTICE(S) on the panels that follow, to tell persons not to operate the refuel/defuel system:
- Refuel/defuel control panels 800VU and 801VU
- Fuel control panel 40VU.
B. Aircraft Maintenance Configuration
(1) Make sure that the ACT is defueled to its unusable fuel level (Ref. AMM TASK 28-25-00-650-001).
(2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(3) Put a STEPLADDER 0.5 M (1.6 FT) below the applicable water drain valve.
Subtask 28-25-00-860-069-B ** ON A/C NOT FOR ALL (1) Make sure that the ACT is defueled to its unusable fuel level (Ref. AMM TASK 28-25-00-650-001).
(2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(3) Put a STEPLADDER 0.5 M (1.6 FT) below the applicable water drain valve.
B. Aircraft Maintenance Configuration
(1) Make sure that the applicable ACT is defueled to its unusable fuel level (Ref. AMM TASK 28-25-00-650-001).
(2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(3) Put a STEPLADDER 0.5 M (1.6 FT) below the applicable water drain valve.
Subtask 28-25-00-860-082-A ** ON A/C NOT FOR ALL (1) Make sure that the applicable ACT is defueled to its unusable fuel level (Ref. AMM TASK 28-25-00-650-001).
(2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(3) Put a STEPLADDER 0.5 M (1.6 FT) below the applicable water drain valve.
C. Aircraft Maintenance Configuration
(1) Make sure that each applicable ACT is defueled to its unusable fuel level (Ref. AMM TASK 28-25-00-650-001).
(2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(3) Put a STEPLADDER 0.5 M (1.6 FT) below the applicable water drain valve.
Subtask 28-25-00-865-066-A ** ON A/C NOT FOR ALL (1) Make sure that each applicable ACT is defueled to its unusable fuel level (Ref. AMM TASK 28-25-00-650-001).
(2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(3) Put a STEPLADDER 0.5 M (1.6 FT) below the applicable water drain valve.
D. Open, safety and tag this(these) circuit breaker(s):
Subtask 28-25-00-010-092-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | ACT PUMP SUPPLY | 25QH | Q29 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/INLET VLV/MOT1/AFT 2 | 84QH | L29 |
| 121VU | FUEL/INLET VLV/MOT1/MAN SPLY/AFT 1 | 46QH | L28 |
| 121VU | FUEL/ACT/FUEL PUMP/SPLY | 25QH | Q29 |
E. Get Access (If ACT1 Installed)
(1) Remove the applicable access panels:
Subtask 28-25-00-010-092-B ** ON A/C NOT FOR ALL (1) Remove the applicable access panels:
- for the water drain-valve (174QM1), remove 198QB and 154AZ
- for the water drain-valve (175QM1), remove 154BR.
NOTE: It is necessary to remove access panel 198QB to gain access to panel 154AZ.
E. Get Access (If ACT1 and ACT2 Installed)
(1) Remove the applicable access panels:
Subtask 28-25-00-010-087-F ** ON A/C NOT FOR ALL (1) Remove the applicable access panels:
- for the water drain-valve (174QM1), remove 198QB and 154AZ
- for the water drain-valve (175QM1), remove 154BR
- for the water drain-valve (174QM2), remove 154DR
- for the water drain-valve (175QM2), remove 153BR.
NOTE: It is necessary to remove access panel 198QB to gain access to panel 154AZ.
F. Get Access
(1) Remove the applicable access panel(s):
Subtask 28-25-00-480-050-A ** ON A/C NOT FOR ALL (1) Remove the applicable access panel(s):
- For water drain-valve 226QM1, remove 197AB and 153AZ (Ref. AMM TASK 53-35-13-000-001)
- For water drain-valve 226QM2, remove 197GB (Ref. AMM TASK 53-35-13-000-001).
G. Installation of the Water Drain Adaptor
(1) Put a CONTAINER 30 L(8 USGAL) below the applicable water drain valve.
(2) Install the 98D28108293000 ADAPTER-WATER DRAIN, ADDITIONAL CENTER TANK or 98D28108293001 ADAPTER-WATER DRAIN, ADDITIONAL CENTER TANK as follows:
(a) Put the thrust rod (2) into the sleeve (1).
(b) Install the sleeve (1) in the water drain-valve tube.
(c) Hold the sleeve (1) and turn the nut (3) clockwise against the nut (4) to hold the water drain adaptor in position.
Subtask 28-25-00-480-050-C ** ON A/C NOT FOR ALL (1) Put a CONTAINER 30 L(8 USGAL) below the applicable water drain valve.
(2) Install the 98D28108293000 ADAPTER-WATER DRAIN, ADDITIONAL CENTER TANK or 98D28108293001 ADAPTER-WATER DRAIN, ADDITIONAL CENTER TANK as follows:
(a) Put the thrust rod (2) into the sleeve (1).
(b) Install the sleeve (1) in the water drain-valve tube.
(c) Hold the sleeve (1) and turn the nut (3) clockwise against the nut (4) to hold the water drain adaptor in position.
G. Installation of the Water Drain Adapter
(1) Put a CONTAINER 30 L(8 USGAL) below the applicable water drain valve.
(2) Install the 98D28108293000 ADAPTER-WATER DRAIN, ADDITIONAL CENTER TANK or 98D28108293002 ADAPTER-WATER DRAIN, ADDITIONAL CENTER TANK as follows:
(a) Put the thrust rod (2) into the sleeve (1).
(b) Install the sleeve (1) in the water drain-valve tube.
(c) Hold the sleeve (1) and turn the nut (3) clockwise against the nut (4) to hold the water drain adapter in position.
4. Procedure(1) Put a CONTAINER 30 L(8 USGAL) below the applicable water drain valve.
(2) Install the 98D28108293000 ADAPTER-WATER DRAIN, ADDITIONAL CENTER TANK or 98D28108293002 ADAPTER-WATER DRAIN, ADDITIONAL CENTER TANK as follows:
(a) Put the thrust rod (2) into the sleeve (1).
(b) Install the sleeve (1) in the water drain-valve tube.
(c) Hold the sleeve (1) and turn the nut (3) clockwise against the nut (4) to hold the water drain adapter in position.
Subtask 28-25-00-680-052-A ** ON A/C NOT FOR ALL
A. To Drain the Remaining Fuel
(2) Use a non metallic probe to lift the thrust rod (2) against the water drain-valve. This causes the water drain-valve to open and the fuel to flow.
(3) Continue to hold the water drain-valve open until the fuel flow stops. Make sure that there is sufficient space in the container for all the drained fuel.
Subtask 28-25-00-680-053-A ** ON A/C NOT FOR ALL WARNING:
BE CAREFUL NOT TO GET AIRCRAFT FUEL IN YOUR MOUTH OR IN YOUR EYES.
IF YOU GET FUEL ON YOUR SKIN OR ON YOUR CLOTHES, FLUSH IT IMMEDIATELY WITH WATER.
IF NECESSARY, GET MEDICAL HELP.
AIRCRAFT FUEL IS POISONOUS.
WARNING:
DO NOT GET YOUR CLOTHES SOAKED WITH FUEL.
WARNING:
BE CAREFUL WHEN YOU OPEN THE WATER DRAIN VALVES. SOME FUEL CAN ALSO COME OUT OF THE VALVES.
(1) Make sure that the container is in the correct position below the thrust rod (2). (2) Use a non metallic probe to lift the thrust rod (2) against the water drain-valve. This causes the water drain-valve to open and the fuel to flow.
(3) Continue to hold the water drain-valve open until the fuel flow stops. Make sure that there is sufficient space in the container for all the drained fuel.
B. To Drain the Remaining Fuel
(2) Use a PROBE - NON METALLIC, FLEXIBLE to lift the thrust rod (2) against the water drain valve. This causes the water drain valve to open and the fuel to flow.
(3) Continue to hold the water drain valve open until the fuel flow stops. Make sure that there is sufficient space in the container for all the drained fuel.
Subtask 28-25-00-680-051-D ** ON A/C NOT FOR ALL WARNING:
BE CAREFUL WHEN YOU OPEN THE WATER DRAIN VALVES. SOME FUEL CAN ALSO COME OUT OF THE VALVES.
(1) Make sure that the container is in the correct position below the thrust rod (2). (2) Use a PROBE - NON METALLIC, FLEXIBLE to lift the thrust rod (2) against the water drain valve. This causes the water drain valve to open and the fuel to flow.
(3) Continue to hold the water drain valve open until the fuel flow stops. Make sure that there is sufficient space in the container for all the drained fuel.
C. To Fully Drain the ACT
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) On the right side of the belly fairing, open quick-release access-door 192MB.
(3) On refuel/defuel control-panel 801VU, make sure that:
(a) All REFUEL VALVE switches are in the NORM and safe position.
(4) In the cockpit, on ACT-fuel control-panel 28VU:
(a) Make sure that the ACT XFR rotary switch is in the OFF position.
(b) Push the ACT XFR MODE SEL pushbutton switch (the MAN legend comes on and the ACT vent valve closes).
(6) Open and safety aft cargo-compartment-door 826 (Ref. AMM TASK 52-30-00-860-001).
(7) Put the WARNING NOTICE(S) on the aft-cargo loading-system control-panel to tell persons not to operate the aft-cargo loading-system.
(8) In the aft cargo compartment:
(a) Set CARGO COMPT LIGHT switch 8LU to the ON position.
(b) Remove ceiling panel 151NC to get access to ACT-pressurization system-test ports T1 and T2 (Ref. AMM TASK 25-55-11-000-002).
(9) In the aft cargo compartment at test port T1:
(11) In the aft cargo compartment at test port T2:
(14) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(15) Start the ground pressure generator.
(16) Let the ground pressure generator pressurize the ACT system.
(18) Continue to hold the water drain valve in the open position until the fuel flow stops:
(a) Make sure that there is sufficient space in the CONTAINER 30 L(8 USGAL) for all the drained fuel.
(19) When the fuel flow from the water drain valve stops:
(Ref. AMM TASK 24-41-00-861-002).
(21) At test port T1:
(a) Disconnect the ground pressure generator from the low pressure gage.
(b) Remove the low pressure gage and the ADAPTER 0,75 IN (19,05 MM) - SQUARE DRIVE.
(22) At test port T2, remove the low pressure gage and the ADAPTER 0,75 IN (19,05 MM) - SQUARE DRIVE.
(23) In the cockpit, on ACT fuel control-panel 28VU, release the ACT XFR MODE SEL pushbutton switch (the MAN legend goes off).
(25) Set CARGO COMPT LIGHT switch 8LU to the OFF position.
(26) Close aft cargo-compartment-door 826 (Ref. AMM TASK 52-30-00-860-002).
(27) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
Subtask 28-25-00-680-051-B (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) On the right side of the belly fairing, open quick-release access-door 192MB.
(3) On refuel/defuel control-panel 801VU, make sure that:
(a) All REFUEL VALVE switches are in the NORM and safe position.
(4) In the cockpit, on ACT-fuel control-panel 28VU:
(a) Make sure that the ACT XFR rotary switch is in the OFF position.
(b) Push the ACT XFR MODE SEL pushbutton switch (the MAN legend comes on and the ACT vent valve closes).
NOTE: The fuel inlet valve in each ACT will stay closed.
NOTE: The ACT FWD vent-isolation valve is permanently open.
(5) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at aft cargo-compartment-door 826. (6) Open and safety aft cargo-compartment-door 826 (Ref. AMM TASK 52-30-00-860-001).
(7) Put the WARNING NOTICE(S) on the aft-cargo loading-system control-panel to tell persons not to operate the aft-cargo loading-system.
(8) In the aft cargo compartment:
(a) Set CARGO COMPT LIGHT switch 8LU to the ON position.
(b) Remove ceiling panel 151NC to get access to ACT-pressurization system-test ports T1 and T2 (Ref. AMM TASK 25-55-11-000-002).
(9) In the aft cargo compartment at test port T1:
- Connect the ADAPTER 0,75 IN (19,05 MM) - SQUARE DRIVE
- Connect the GAGE 5 BAR (75 PSI) - PRESSURE
- Connect the GROUND PRESSURE GENERATOR - 0 TO 2 BAR (0 TO 30 PSI).
(11) In the aft cargo compartment at test port T2:
- Connect the ADAPTER 0,75 IN (19,05 MM) - SQUARE DRIVE
- Connect the GAGE 5 BAR (75 PSI) - PRESSURE.
WARNING:
DO NOT OPEN THE WATER DRAIN VALVE(S) WHEN THE TANK(S) IS/ARE PRESSURIZED. IF YOU DO, FUEL CAN COME OUT OF THE VALVE(S) WITH FORCE AND CAUSE YOU INJURY.
(13) Use the PROBE - NON METALLIC, FLEXIBLE to lift the thrust rod (2) against the water drain valve. This causes the water drain valve to open. (14) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(15) Start the ground pressure generator.
(16) Let the ground pressure generator pressurize the ACT system.
NOTE: The ACT pressure reducing-valve decreases the pressure from 0 -0 bar or +1 bar (0 -0 psi or +14.50 psi) to 0.345 bar (5.00 psi).
The pressure in the ACT will increase and cause the remaining fuel to flow through the water drain valve.
(17) Make sure that the pressure on the pressure gage at test port T2 stays below 0.345 bar (5.00 psi). If the pressure increases above 0.345 bar (5.00 psi), stop the ground pressure generator immediately. The pressure in the ACT will increase and cause the remaining fuel to flow through the water drain valve.
(18) Continue to hold the water drain valve in the open position until the fuel flow stops:
(a) Make sure that there is sufficient space in the CONTAINER 30 L(8 USGAL) for all the drained fuel.
(19) When the fuel flow from the water drain valve stops:
- Stop the ground pressure generator
- Carefully release the pressure at the ground pressure generator.
(Ref. AMM TASK 24-41-00-861-002).
(21) At test port T1:
(a) Disconnect the ground pressure generator from the low pressure gage.
(b) Remove the low pressure gage and the ADAPTER 0,75 IN (19,05 MM) - SQUARE DRIVE.
(22) At test port T2, remove the low pressure gage and the ADAPTER 0,75 IN (19,05 MM) - SQUARE DRIVE.
(23) In the cockpit, on ACT fuel control-panel 28VU, release the ACT XFR MODE SEL pushbutton switch (the MAN legend goes off).
NOTE: The ACT vent valve opens and the pressure in the vent system releases.
(24) Install ceiling panel 151NC to close access to test ports T1 and T2 (Ref. AMM TASK 25-55-11-400-002).(25) Set CARGO COMPT LIGHT switch 8LU to the OFF position.
(26) Close aft cargo-compartment-door 826 (Ref. AMM TASK 52-30-00-860-002).
(27) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
DELETED
Subtask 28-25-00-865-067-A ** ON A/C NOT FOR ALL D. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
5. Close-up| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | ACT PUMP SUPPLY | 25QH | Q29 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/INLET VLV/MOT1/AFT 2 | 84QH | L29 |
| 121VU | FUEL/INLET VLV/MOT1/MAN SPLY/AFT 1 | 46QH | L28 |
| 121VU | FUEL/ACT/FUEL PUMP/SPLY | 25QH | Q29 |
Subtask 28-25-00-080-050-A ** ON A/C NOT FOR ALL
A. Removal of the Water Drain Adaptor
Water Drain Adaptors
Water Drain Adaptor ** ON A/C NOT FOR ALL
Water Drain Adaptors ** ON A/C NOT FOR ALL
(1) When the fuel flow stops, remove the probe to close the water drain-valve.
(2) To release the water drain adaptor from the water drain valve tube:
(a) Hold the sleeve (1) and turn the nut (3) counter clockwise from the nut (4).
(3) Remove the thrust rod (2) from the sleeve (1).
(4) Examine the water drain valve for leakage. Leaks are not permitted.
Subtask 28-25-00-410-087-A ** ON A/C NOT FOR ALL
Water Drain Adaptors
Water Drain Adaptor ** ON A/C NOT FOR ALL
Water Drain Adaptors ** ON A/C NOT FOR ALL (2) To release the water drain adaptor from the water drain valve tube:
(a) Hold the sleeve (1) and turn the nut (3) counter clockwise from the nut (4).
(3) Remove the thrust rod (2) from the sleeve (1).
(4) Examine the water drain valve for leakage. Leaks are not permitted.
B. Close Access (ACT1 Installed)
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the applicable access panel:
Subtask 28-25-00-410-087-B ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the applicable access panel:
B. Close Access (ACT1 and ACT2 Installed)
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the applicable access panel:
Subtask 28-25-00-410-083-F ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the applicable access panel:
C. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the removed access panel(s):
Subtask 28-25-00-942-081-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the removed access panel(s):
- For water drain-valve 226QM1, install 153AZ and 197AB (Ref. AMM TASK 53-35-13-400-001).
- For water drain-valve 226QM2, install 197GB (Ref. AMM TASK 53-35-13-400-001).
D. Removal of Equipment
(1) If installed, remove the safety barriers.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
(4) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(5) To discard the drained fuel, refer to your local regulations.
(1) If installed, remove the safety barriers.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
(4) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(5) To discard the drained fuel, refer to your local regulations.