Visual Check of Fire Extinguisher Bottle Pressure Reading
TASK 26-25-00-200-005-A
Visual Check of Fire Extinguisher Bottle Pressure Reading
Refer to the MPD TASK: 262541-04
VISUAL CHECK OF FIRE EXTINGUISHER BOTTLE PRESSURE READING
2. Job Set-up Information
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 26-25-00-860-050-A
Subtask 26-25-00-210-054-A ** ON A/C NOT FOR ALL
Subtask 26-25-00-410-058-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 04:27:07 UTC
Visual Check of Fire Extinguisher Bottle Pressure Reading
ZONE: 200
FIN: 7910MM
FIN: 7911MM
FIN: 7912MM ** ON A/C NOT FOR ALL
FIN: 7914MM31 ** ON A/C NOT FOR ALL
FIN: 7914MM41 ** ON A/C NOT FOR ALL
FIN: 7914MM42 ** ON A/C NOT FOR ALL
FIN: 7916MM ** ON A/C NOT FOR ALL
FIN: 7917MM ** ON A/C NOT FOR ALL
1. Reason for the JobFIN: 7910MM
FIN: 7911MM
FIN: 7912MM ** ON A/C NOT FOR ALL
FIN: 7914MM31 ** ON A/C NOT FOR ALL
FIN: 7914MM41 ** ON A/C NOT FOR ALL
FIN: 7914MM42 ** ON A/C NOT FOR ALL
FIN: 7916MM ** ON A/C NOT FOR ALL
FIN: 7917MM ** ON A/C NOT FOR ALL
Refer to the MPD TASK: 262541-04
VISUAL CHECK OF FIRE EXTINGUISHER BOTTLE PRESSURE READING
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 200 | UPPER HALF FUSELAGE |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 26-25-00-200-003-A | Remove Lavatory Fire Extinguisher Bottle for Weight Check |
| TASK 26-25-41-000-001-A | Removal of the Fire Extinguisher Bottle |
| TASK 26-25-41-000-802-A | Removal of the Fire Extinguisher Bottle of Lavatory A |
| TASK 26-25-41-000-804-A | Removal of the Fire Extinguisher Bottle of Lavatory DS/ES/HS |
| TASK 26-25-41-000-805-A | Removal of the Fire Extinguisher Bottle of Lavatory WC/FS/GS |
| TASK 26-25-41-400-001-A | Installation of the Fire Extinguisher Bottle |
| TASK 26-25-41-400-802-A | Installation of the Fire Extinguisher Bottle of Lavatory A |
| TASK 26-25-41-400-804-A | Installation of the Fire Extinguisher Bottle of Lavatory DS/ES/HS |
| TASK 26-25-41-400-805-A | Installation of the Fire Extinguisher Bottle of Lavatory WC/FS/GS |
| TASK 25-40-00-00 | LAVATORIES - DESCRIPTION AND OPERATION |
| TASK 26-25-00-00 | LAVATORY FIRE EXTINGUISHING - DESCRIPTION AND OPERATION |
Subtask 26-25-00-860-050-A
A. Aircraft Maintenance Configuration
(1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 26-25-00-010-060-A ** ON A/C NOT FOR ALL (1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
B. Get Access
(1) For the location of this component refer to (Ref. AMM D/O 25-40-00-00), (Ref. AMM D/O 26-25-00-00).
(2) Get access to the lavatory and open the service door.
Subtask 26-25-00-010-060-R ** ON A/C NOT FOR ALL (1) For the location of this component refer to (Ref. AMM D/O 25-40-00-00), (Ref. AMM D/O 26-25-00-00).
(2) Get access to the lavatory and open the service door.
B. Get Access
(1) For the location of this component refer to (Ref. AMM D/O 26-25-00-00).
(2) Get access to related lavatory.
(3) Open the service door.
4. Procedure(1) For the location of this component refer to (Ref. AMM D/O 26-25-00-00).
(2) Get access to related lavatory.
(3) Open the service door.
Subtask 26-25-00-210-054-A ** ON A/C NOT FOR ALL
A. Check of the Pressure Gage of the Fire Extinguisher Bottle
(1) Read the pressure on the pressure gage.
(2) Make sure that the pressure gage shows a correct pressure.
(a) A correct pressure is shown when:
(a) Remove the fire extinguisher bottle for a weight check (Ref. AMM TASK 26-25-00-200-003).
(b) If necessary, replace the fire extinguisher bottle (Ref. AMM TASK 26-25-41-000-001) and (Ref. AMM TASK 26-25-41-400-001).
Subtask 26-25-00-210-056-D ** ON A/C NOT FOR ALL (1) Read the pressure on the pressure gage.
(2) Make sure that the pressure gage shows a correct pressure.
(a) A correct pressure is shown when:
- The gage needle is in the green area.
- The gage needle is on the outer side, to the left of the green area.
- The gage needle is between the red and green area.
- The gage needle is on the outer side, to the right of the green area.
(a) Remove the fire extinguisher bottle for a weight check (Ref. AMM TASK 26-25-00-200-003).
(b) If necessary, replace the fire extinguisher bottle (Ref. AMM TASK 26-25-41-000-001) and (Ref. AMM TASK 26-25-41-400-001).
B. Check of the Pressure Gage of the Fire Extinguisher Bottle
(1) Read the pressure on the pressure gage.
(2) Make sure that the pressure gage shows a correct pressure.
(a) A correct pressure is shown when:
(a) Remove the fire extinguisher bottle for a weight check (Ref. AMM TASK 26-25-00-200-003).
(b) If necessary, replace the fire extinguisher bottle
(Ref. AMM TASK 26-25-41-000-802) and (Ref. AMM TASK 26-25-41-400-802) or
(Ref. AMM TASK 26-25-41-000-804) and (Ref. AMM TASK 26-25-41-400-804).
Subtask 26-25-00-210-056-E ** ON A/C NOT FOR ALL (1) Read the pressure on the pressure gage.
(2) Make sure that the pressure gage shows a correct pressure.
(a) A correct pressure is shown when:
- The gage needle is in the green area.
- The gage needle is on the outer side, to the left of the green area.
- The gage needle is between the red and green area.
- The gage needle is on the outer side, to the right of the green area.
(a) Remove the fire extinguisher bottle for a weight check (Ref. AMM TASK 26-25-00-200-003).
(b) If necessary, replace the fire extinguisher bottle
(Ref. AMM TASK 26-25-41-000-802) and (Ref. AMM TASK 26-25-41-400-802) or
(Ref. AMM TASK 26-25-41-000-804) and (Ref. AMM TASK 26-25-41-400-804).
B. Check of the Pressure Gage of the Fire Extinguisher Bottle
(1) Read the pressure on the pressure gage.
(2) Make sure that the pressure gage shows a correct pressure.
(a) A correct pressure is shown when:
(a) Remove the fire extinguisher bottle for a weight check (Ref. AMM TASK 26-25-00-200-003).
(b) If necessary, replace the fire extinguisher bottle
(Ref. AMM TASK 26-25-41-000-802) and (Ref. AMM TASK 26-25-41-400-802) or
(Ref. AMM TASK 26-25-41-000-804) and (Ref. AMM TASK 26-25-41-400-804) or
(Ref. AMM TASK 26-25-41-000-805) and (Ref. AMM TASK 26-25-41-400-805).
5. Close-up(1) Read the pressure on the pressure gage.
(2) Make sure that the pressure gage shows a correct pressure.
(a) A correct pressure is shown when:
- The gage needle is in the green area.
- The gage needle is on the outer side, to the left of the green area.
- The gage needle is between the red and green area.
- The gage needle is on the outer side, to the right of the green area.
(a) Remove the fire extinguisher bottle for a weight check (Ref. AMM TASK 26-25-00-200-003).
(b) If necessary, replace the fire extinguisher bottle
(Ref. AMM TASK 26-25-41-000-802) and (Ref. AMM TASK 26-25-41-400-802) or
(Ref. AMM TASK 26-25-41-000-804) and (Ref. AMM TASK 26-25-41-400-804) or
(Ref. AMM TASK 26-25-41-000-805) and (Ref. AMM TASK 26-25-41-400-805).
Subtask 26-25-00-410-058-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the service door and close the door of the lavatory.
Subtask 26-25-00-410-058-R ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the service door and close the door of the lavatory.
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the service door.
(3) Close the door of related lavatory.
Subtask 26-25-00-860-051-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the service door.
(3) Close the door of related lavatory.
B. Put the aircraft back to its initial configuration.
(1) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
(1) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).