W DOC AIRBUS | AMM A320F

Remove Lavatory Fire Extinguisher Bottle for Weight Check


TASK 26-25-00-200-003-A
Remove Lavatory Fire Extinguisher Bottle for Weight Check


ZONE: 200
FIN: 7910MM
FIN: 7911MM
FIN: 7912MM ** ON A/C NOT FOR ALL
FIN: 7914MM31 ** ON A/C NOT FOR ALL
FIN: 7914MM41 ** ON A/C NOT FOR ALL
FIN: 7914MM42 ** ON A/C NOT FOR ALL
FIN: 7916MM ** ON A/C NOT FOR ALL
FIN: 7917MM ** ON A/C NOT FOR ALL
1. Reason for the Job
Refer to the MPD TASK: 262541-02
REMOVE LAVATORY FIRE EXTINGUISHER BOTTLE FOR WEIGHT CHECK
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
200
UPPER HALF FUSELAGE
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 26-25-41-000-001-A
Removal of the Fire Extinguisher Bottle
TASK 26-25-41-000-802-A
Removal of the Fire Extinguisher Bottle of Lavatory A
TASK 26-25-41-000-804-A
Removal of the Fire Extinguisher Bottle of Lavatory DS/ES/HS
TASK 26-25-41-000-805-A
Removal of the Fire Extinguisher Bottle of Lavatory WC/FS/GS
TASK 26-25-41-400-001-A
Installation of the Fire Extinguisher Bottle
TASK 26-25-41-400-802-A
Installation of the Fire Extinguisher Bottle of Lavatory A
TASK 26-25-41-400-804-A
Installation of the Fire Extinguisher Bottle of Lavatory DS/ES/HS
TASK 26-25-41-400-805-A
Installation of the Fire Extinguisher Bottle of Lavatory WC/FS/GS
3. Job Set-up
Subtask 26-25-00-020-054-A ** ON A/C NOT FOR ALL
A. Removal of the Fire Extinguisher Bottle
   (1) Remove the fire extinguisher bottle (Ref. AMM TASK 26-25-41-000-001).
Subtask 26-25-00-020-056-D ** ON A/C NOT FOR ALL
B. Removal of the Fire Extinguisher Bottle
   (1) Remove the fire extinguisher bottle
(Ref. AMM TASK 26-25-41-000-802) or (Ref. AMM TASK 26-25-41-000-804).
Subtask 26-25-00-020-056-E ** ON A/C NOT FOR ALL
B. Removal of the Fire Extinguisher Bottle
   (1) Remove the fire extinguisher bottle
(Ref. AMM TASK 26-25-41-000-802) or (Ref. AMM TASK 26-25-41-000-804) or (Ref. AMM TASK 26-25-41-000-805).
4. Procedure
Subtask 26-25-00-280-052-A
A. Weight Check of the Fire-Extinguisher Bottle
   (1) Remove the fire-extinguisher bottle for the weight check.
5. Close-up
Subtask 26-25-00-420-054-A ** ON A/C NOT FOR ALL
A. Installation of the Fire Extinguisher Bottle
   (1) Install a serviceable fire extinguisher bottle (Ref. AMM TASK 26-25-41-400-001).
Subtask 26-25-00-420-056-D ** ON A/C NOT FOR ALL
B. Installation of the Fire Extinguisher Bottle
   (1) Install a serviceable fire extinguisher bottle
(Ref. AMM TASK 26-25-41-400-802) or (Ref. AMM TASK 26-25-41-400-804).
Subtask 26-25-00-420-056-E ** ON A/C NOT FOR ALL
B. Installation of the Fire Extinguisher Bottle
   (1) Install a serviceable fire extinguisher bottle
(Ref. AMM TASK 26-25-41-400-802) or (Ref. AMM TASK 26-25-41-400-804) or (Ref. AMM TASK 26-25-41-400-805).
[Rev.10 from 2021] 2026.04.01 06:46:27 UTC