W DOC AIRBUS | AMM A320F

Removal of the Fire Extinguisher Bottle of Lavatory WC/FS/GS


TASK 26-25-41-000-805-A
Removal of the Fire Extinguisher Bottle of Lavatory WC/FS/GS


ZONE: 260
FIN: 7916MM ** ON A/C NOT FOR ALL
FIN: 7917MM ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
PIN - RELEASE
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
260
AFT CABIN UTILITY AREA
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 26-25-00-00
LAVATORY FIRE EXTINGUISHING - DESCRIPTION AND OPERATION
3. Job Set-up
Subtask 26-25-41-860-055-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 26-25-41-010-055-B ** ON A/C NOT FOR ALL
B. Get Access
   (1) For the location of this component refer to (Ref. AMM D/O 26-25-00-00).
   (2) Get access to the related lavatory.
   (3) Use PIN - RELEASE to open the fire extinguisher door (1).
NOTE: Make sure that the release pin has a length of 1.543 in. (39.192 mm).
4. Procedure
Subtask 26-25-41-020-054-B ** ON A/C NOT FOR ALL
CAUTION: MAKE SURE THAT YOU DO NOT BEND THE DISCHARGE TUBE(S) WHEN YOU REMOVE OR INSTALL THE FIRE EXTINGUISHER. IF YOU DO, YOU CAN CAUSE DAMAGE TO THE JOINT BETWEEN THE DISCHARGE TUBE AND THE CONTAINER.
A. Removal of the Fire Extinguisher Bottle
   (1) Remove the screws (2) and the washers (3).
   (2) Carefully remove the fire extinguisher bottle (4) from the waste-bin housing.
[Rev.10 from 2021] 2026.03.31 23:47:08 UTC