W DOC AIRBUS | AMM A320F

Removal of the Fire Extinguisher Bottle of Lavatory DS/ES/HS


TASK 26-25-41-000-804-A
Removal of the Fire Extinguisher Bottle of Lavatory DS/ES/HS


ZONE: 200
FIN: 7911MM ** ON A/C NOT FOR ALL
FIN: 7912MM ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
200
UPPER HALF FUSELAGE
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 26-25-00-00
LAVATORY FIRE EXTINGUISHING - DESCRIPTION AND OPERATION
3. Job Set-up
Subtask 26-25-41-860-054-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 26-25-41-010-054-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) For the location of this component refer to (Ref. AMM D/O 26-25-00-00).
   (2) Get access to the related lavatory.
   (3) Open the service door (1).
   (4) Remove the waste bin (2).
   (5) Remove the screws (10), the washers (9), the lanyard (7) and the cover (8).
4. Procedure
Subtask 26-25-41-020-053-A ** ON A/C NOT FOR ALL
CAUTION: MAKE SURE THAT YOU DO NOT BEND THE DISCHARGE TUBE(S) WHEN YOU REMOVE OR INSTALL THE FIRE EXTINGUISHER. IF YOU DO, YOU CAN CAUSE DAMAGE TO THE JOINT BETWEEN THE DISCHARGE TUBE AND THE CONTAINER.
A. Removal of the Fire Extinguisher Bottle
   (1) Remove the screws (6).
   (2) Carefully remove the fire extinguisher bottle (3) and the washers (5) from the waste-bin housing.
   (3) If necessary, remove the nut-clips (4) from the fire extinguisher bottle (3).
[Rev.10 from 2021] 2026.04.01 06:46:24 UTC