W DOC AIRBUS | AMM A320F

Remove Smoke Detector for Cleaning


TASK 26-17-15-100-003-A
Remove Smoke Detector for Cleaning


ZONE: 200
FIN: 1WQ ** ON A/C NOT FOR ALL
FIN: 14WQ ** ON A/C NOT FOR ALL
FIN: 15WQ ** ON A/C NOT FOR ALL
FIN: 23WQ ** ON A/C NOT FOR ALL
FIN: 3WQ ** ON A/C NOT FOR ALL
FIN: 4WQ
FIN: 5WQ ** ON A/C NOT FOR ALL
FIN: 6WQ ** ON A/C NOT FOR ALL
FIN: 8WQ ** ON A/C NOT FOR ALL
1. Reason for the Job
Refer to the MPD TASK: 261700-04
REMOVE SMOKE DETECTOR FOR CLEANING
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
200
UPPER HALF FUSELAGE
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 26-17-15-000-001-A
Removal of the Lavatory Smoke Detector
TASK 26-17-15-000-008-A
Removal of the Lavatory Smoke Detector
TASK 26-17-15-000-802-A
Removal of the Smoke Detector of Lavatory A
TASK 26-17-15-000-808-A
Removal of the Smoke Detector of Lavatory DS/ES/HS
TASK 26-17-15-000-809-A
Removal of the Smoke Detector of Lavatory WC/FS/GS
TASK 26-17-15-400-001-A
Installation of the Lavatory Smoke Detector
TASK 26-17-15-400-007-A
Installation of the Lavatory Smoke Detector
TASK 26-17-15-400-802-A
Installation of the Smoke Detector of Lavatory A
TASK 26-17-15-400-808-A
Installation of the Smoke Detector of Lavatory DS/ES/HS
TASK 26-17-15-400-809-A
Installation of the Smoke Detector of Lavatory WC/FS/GS
3. Job Set-up
Subtask 26-17-15-020-057-A ** ON A/C NOT FOR ALL
A. Remove the related smoke detector from the related lavatory:
Subtask 26-17-15-020-057-D ** ON A/C NOT FOR ALL
A. Remove the related smoke detector from the related lavatory:
Subtask 26-17-15-020-057-O ** ON A/C NOT FOR ALL
A. Remove the related smoke detector from the related lavatory:
Subtask 26-17-15-020-057-Q ** ON A/C NOT FOR ALL
A. Remove the related smoke detector from the related lavatory:
Subtask 26-17-15-020-057-U ** ON A/C NOT FOR ALL
A. Remove the related smoke detector from the related lavatory:
Subtask 26-17-15-020-068-E ** ON A/C NOT FOR ALL
B. Removal of the Smoke Detector
   (1) Remove the smoke detector
(Ref. AMM TASK 26-17-15-000-802) or (Ref. AMM TASK 26-17-15-000-808).
Subtask 26-17-15-020-068-F ** ON A/C NOT FOR ALL
B. Removal of the Smoke Detector:
   (1) Remove the smoke detector
(Ref. AMM TASK 26-17-15-000-802) or (Ref. AMM TASK 26-17-15-000-808) or (Ref. AMM TASK 26-17-15-000-809).
4. Procedure
Subtask 26-17-15-110-052-A
A. Cleaning
   (1) Send the related smoke detector to the workshop.
5. Close-up
Subtask 26-17-15-420-057-A ** ON A/C NOT FOR ALL
A. Install a serviceable smoke detector in the related lavatory:
Subtask 26-17-15-420-057-D ** ON A/C NOT FOR ALL
A. Install a serviceable smoke detector in the related lavatory:
Subtask 26-17-15-420-057-O ** ON A/C NOT FOR ALL
A. Install a serviceable smoke detector in the related lavatory:
Subtask 26-17-15-420-057-Q ** ON A/C NOT FOR ALL
A. Install a serviceable smoke detector in the related lavatory:
Subtask 26-17-15-420-057-U ** ON A/C NOT FOR ALL
A. Install a serviceable smoke detector in the related lavatory:
Subtask 26-17-15-420-068-E ** ON A/C NOT FOR ALL
B. Installation of the Smoke Detector
   (1) Install a serviceable smoke detector
(Ref. AMM TASK 26-17-15-400-802) or (Ref. AMM TASK 26-17-15-400-808).
Subtask 26-17-15-420-068-F ** ON A/C NOT FOR ALL
B. Installation of the Smoke Detector
   (1) Install a serviceable smoke detector
(Ref. AMM TASK 26-17-15-400-802) or (Ref. AMM TASK 26-17-15-400-808) or (Ref. AMM TASK 26-17-15-400-809).