W DOC AIRBUS | AMM A320F

Removal of the Smoke Detector of Lavatory WC/FS/GS


TASK 26-17-15-000-809-A
Removal of the Smoke Detector of Lavatory WC/FS/GS


ZONE: 260
FIN: 23WQ ** ON A/C NOT FOR ALL
FIN: 3WQ ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
1
SCREWDRIVER - SMALL
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
260
AFT CABIN UTILITY AREA
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 26-17-00-00
LAVATORY SMOKE DETECTION - DESCRIPTION AND OPERATION
3. Job Set-up
Subtask 26-17-15-860-066-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 26-17-15-875-053-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUCOM/CIDS/DEU B/ESS153RHG03
** ON A/C NOT FOR ALL
49VUCOM/CIDS/DEU B ESS/R420RHG05
49VUCOM/CIDS/DEU B ESS/L419RHG04
49VUCOM/CIDS/DEU A ESS/2 R466RHHA12
49VUCOM/CIDS/DEU A ESS/2 L465RHHA11
** ON A/C NOT FOR ALL
121VUCOM / CIDS / DEU B / NORM FWD193RHM09
121VUCOM/CIDS/DEU B/BAT143RHN12
** ON A/C NOT FOR ALL
121VUCOM NAV/CIDS/DEU A NORM/R AFT668RHM14
121VUCOM NAV/CIDS/DEU A NORM/L AFT667RHM13
121VUCOM NAV/CIDS/DEU B NORM/R620RHM08
121VUCOM NAV/CIDS/DEU B NORM/L619RHM07
** ON A/C NOT FOR ALL
2001VUCIDS-DEU B-NORM-AFT194RHC08
Subtask 26-17-15-010-080-B ** ON A/C NOT FOR ALL
C. Get Access
F Smoke Detector of Lavatory FS/GS ** ON A/C NOT FOR ALL
   (1) For the location of this component refer to (Ref. AMM D/O 26-17-00-00).
   (2) Get access to the related lavatory.
   (3) Get access to the smoke detector (5):
     (a) Put the SCREWDRIVER - SMALL into the access hole (10) and open the air-extraction panel (9).
     (b) Push the hooks (6) and remove the grille (8) and the air-extraction filter (7) from the air-extraction panel (9).
4. Procedure
Subtask 26-17-15-020-066-B ** ON A/C NOT FOR ALL
A. Removal of the Smoke Detector
F Smoke Detector of Lavatory FS/GS ** ON A/C NOT FOR ALL
NOTE: The procedure to remove all the smoke detectors is the same. Thus, the procedure to remove only one smoke detector is given here.
   (1) Disconnect the electrical connector (2) from the smoke detector (5).
   (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (3) Remove the screws (3) and the washers (4).
   (4) Remove the smoke detector (5) from the air-extraction panel (9).
[Rev.10 from 2021] 2026.03.31 23:44:19 UTC