Detailed Inspection of EWIS Installed in the Hot Section (EWIS)
TASK 24-92-00-220-004-A
Detailed Inspection of EWIS Installed in the Hot Section (EWIS)
Refer to the MPD TASK: 200453-01
DETAILED INSPECTION OF EWIS INSTALLED IN THE HOT SECTION (EWIS)
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 24-92-00-941-057-A ** ON A/C NOT FOR ALL
Subtask 24-92-00-220-054-A ** ON A/C NOT FOR ALL
Subtask 24-92-00-410-163-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:26:05 UTC
Detailed Inspection of EWIS Installed in the Hot Section (EWIS)
ZONE: 453
ZONE: 454
ZONE: 463
ZONE: 464
FIN: 1000EM1 ** ON A/C NOT FOR ALL
FIN: 1000EM2 ** ON A/C NOT FOR ALL
1. Reason for the JobZONE: 454
ZONE: 463
ZONE: 464
FIN: 1000EM1 ** ON A/C NOT FOR ALL
FIN: 1000EM2 ** ON A/C NOT FOR ALL
Refer to the MPD TASK: 200453-01
DETAILED INSPECTION OF EWIS INSTALLED IN THE HOT SECTION (EWIS)
NOTE: This is an EWIS (Electrical Wiring Interconnection System) procedure. EWIS is defined in ESPM 20-33-11.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| No specific | 1 | FLASHLIGHT |
| No specific | 1 | MIRROR - INSPECTION |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 453 | HOT SECTION |
| 454 | HOT SECTION |
| 463 | HOT SECTION |
| 464 | HOT SECTION |
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR, 451AL, 452AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR, 461AL, 462AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 71-13-00-010-010-A | Opening of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 71-13-00-010-040-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-010-040-B | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-010-A | Closing of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 71-13-00-410-040-A | Closing of the Fan Cowl Doors |
| TASK 71-13-00-410-040-B | Closing of the Fan Cowl Doors |
| TASK 78-30-00-040-012-A | Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance |
| TASK 78-30-00-081-041-A | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-081-041-B | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-440-012-A | Re-activation of the Thrust Reverser Hydraulic Control Unit (HCU) after Ground Maintenance |
| TASK 78-30-00-481-041-A | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-30-00-481-041-B | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-32-00-010-010-A | Opening of the Thrust Reverser Halves |
| TASK 78-32-00-410-010-A | Closing of the Thrust Reverser Halves |
| TASK 78-36-00-010-040-A | Opening of the Thrust Reverser Doors |
| TASK 78-36-00-010-040-B | Opening of the Thrust Reverser Doors |
| TASK 78-36-00-410-040-A | Closing of the Thrust Reverser Doors |
| TASK 78-36-00-410-040-B | Closing of the Thrust Reverser Doors |
Subtask 24-92-00-941-057-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(3) On the overhead maintenance panel 50VU:
Subtask 24-92-00-010-083-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
- Put a WARNING NOTICE(S) in position to tell persons not to start the engine.
(3) On the overhead maintenance panel 50VU:
- Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
B. Get Access
(1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below the engine.
(2) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
Subtask 24-92-00-040-051-A ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below the engine.
(2) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
C. Deactivation of the Thrust Reverser
Subtask 24-92-00-010-083-B ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-481-041). D. Get Access
(1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below the engine.
(2) Open the fan cowls (Ref. AMM TASK 71-13-00-010-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
Subtask 24-92-00-040-051-B ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below the engine.
(2) Open the fan cowls (Ref. AMM TASK 71-13-00-010-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
E. Deactivation of the Thrust Reverser
Subtask 24-92-00-010-083-D ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(1) Deactivate the thrust-reverser Hydraulic Control Unit (HCU) (Ref. AMM TASK 78-30-00-040-012). F. Get Access
(1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below the engine.
(2) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
Subtask 24-92-00-040-051-D ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below the engine.
(2) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
G. Deactivation of the Thrust Reverser
Subtask 24-92-00-862-073-A ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-481-041). H. Make sure that the aircraft electrical circuits are de-energized
(Ref. AMM TASK 24-41-00-862-002).
Subtask 24-92-00-010-084-A ** ON A/C NOT FOR ALL (Ref. AMM TASK 24-41-00-862-002).
I. Get Access
(1) Open the thrust reverser doors (Ref. AMM TASK 78-36-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
Subtask 24-92-00-010-084-B ** ON A/C NOT FOR ALL (1) Open the thrust reverser doors (Ref. AMM TASK 78-36-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
I. Get Access
(1) Open the thrust reverser halves (Ref. AMM TASK 78-32-00-010-010):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
Subtask 24-92-00-010-084-D ** ON A/C NOT FOR ALL (1) Open the thrust reverser halves (Ref. AMM TASK 78-32-00-010-010):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
I. Get Access
(1) Open the thrust reverser doors (Ref. AMM TASK 78-36-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
4. Procedure(1) Open the thrust reverser doors (Ref. AMM TASK 78-36-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
Subtask 24-92-00-220-054-A ** ON A/C NOT FOR ALL
A. Detailed Inspection of All Wiring installed in the Hot Section
(1) Do a detailed inspection of the wiring to make sure that there is no signs of ageing, alteration, overheating, scaling and deformation.
(a) Use a FLASHLIGHT or a MIRROR - INSPECTION, if necessary.
(b) Make sure that there is no dust, fuel or oil contamination.
5. Close-up(1) Do a detailed inspection of the wiring to make sure that there is no signs of ageing, alteration, overheating, scaling and deformation.
(a) Use a FLASHLIGHT or a MIRROR - INSPECTION, if necessary.
(b) Make sure that there is no dust, fuel or oil contamination.
Subtask 24-92-00-410-163-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser doors (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
Subtask 24-92-00-440-050-A ** ON A/C NOT FOR ALL Subtask 24-92-00-410-083-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser doors (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
C. Close Access
(1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
Subtask 24-92-00-410-163-B ** ON A/C NOT FOR ALL (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
D. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser halves (Ref. AMM TASK 78-32-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
Subtask 24-92-00-440-050-B ** ON A/C NOT FOR ALL Subtask 24-92-00-410-083-B ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser halves (Ref. AMM TASK 78-32-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
F. Close Access
(1) Close the fan cowls (Ref. AMM TASK 71-13-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
Subtask 24-92-00-410-163-D ** ON A/C NOT FOR ALL (1) Close the fan cowls (Ref. AMM TASK 71-13-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
G. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser doors (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
Subtask 24-92-00-440-050-D ** ON A/C NOT FOR ALL Subtask 24-92-00-410-083-D ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser doors (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.