Apply Temporary Protection to End Fittings of Electrical Conduits in Wing Tip
TASK 24-92-00-210-005-A
Apply Temporary Protection to End Fittings of Electrical Conduits in Wing Tip
Refer to the MPD TASK: 240000-09
APPLY TEMPORARY PROTECTION TO END FITTINGS OF ELECTRICAL CONDUITS IN WING TIP
To apply temporary protection on the end fittings of the electrical conduits in the wing tip.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 24-92-00-862-054-A Subtask 24-92-00-869-059-A Subtask 24-92-00-010-054-B ** ON A/C NOT FOR ALL
Subtask 24-92-00-210-054-A
Subtask 24-92-00-410-055-B ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:25:43 UTC
Apply Temporary Protection to End Fittings of Electrical Conduits in Wing Tip
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
MAKE SURE THAT YOU OBEY ALL THE WARNINGS AND THE CAUTIONS INCLUDED IN THE REFERENCED PROCEDURES.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobRefer to the MPD TASK: 240000-09
APPLY TEMPORARY PROTECTION TO END FITTINGS OF ELECTRICAL CONDUITS IN WING TIP
To apply temporary protection on the end fittings of the electrical conduits in the wing tip.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | AR | BRUSH - BRISTLED |
| No specific | AR | SPRAY - BOTTLE, PUMP TYPE (NON AEROSOL) |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.12ACB1) | Corrosion Preventive Compound-Heavy Duty Hard Film - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 534 | WING TIP |
| 634 | WING TIP |
| 534BB, 534CB, 634BB, 634CB | |
| 534AB, 634AB |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-34-24-869-002-A | Aircraft Grounding (Earthing) for the Maintenance Operations |
| TASK 12-34-24-869-002-A-01 | Aircraft Grounding (Earthing) during Transit, Turnaround or Overnight Stop |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 33-41-11-000-001-A | Removal of the Wingtip Navigation Light |
| TASK 33-41-11-000-802-A | Removal of the Navigation Light - Sharklet |
| TASK 33-41-11-400-001-A | Installation of the Wingtip Navigation Light |
| TASK 33-41-11-400-802-A | Installation of the Navigation Light - Sharklet |
| TASK 33-48-14-000-001-A | Removal of the Strobe Light |
| TASK 33-48-14-000-802-A | Removal of the Strobe Light - Sharklet |
| TASK 33-48-14-400-001-A | Installation of the Strobe Light |
| TASK 33-48-14-400-802-A | Installation of the Strobe Light - Sharklet |
| TASK 57-31-23-000-802-A | Removal of the Sharklet Access Panels |
| TASK 57-31-23-400-802-A | Installation of the Sharklet Access Panels |
| ESPM 203330 | |
| TASK 57-39-00-00 | MISCELLANEOUS - DESCRIPTION AND OPERATION |
Subtask 24-92-00-862-054-A Subtask 24-92-00-869-059-A Subtask 24-92-00-010-054-B ** ON A/C NOT FOR ALL
C. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the wing tip.
(2) For the left wing:
(a) Remove access panel 534AB.
(3) For the right wing:
(a) Remove access panel 634AB.
(4) Remove wing-tip navigation light 9LA (10LA) (Ref. AMM TASK 33-41-11-000-001).
(5) Remove the sharklet strobe light (Ref. AMM TASK 33-48-14-000-001).
Subtask 24-92-00-010-054-C ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the wing tip.
(2) For the left wing:
(a) Remove access panel 534AB.
(3) For the right wing:
(a) Remove access panel 634AB.
(4) Remove wing-tip navigation light 9LA (10LA) (Ref. AMM TASK 33-41-11-000-001).
(5) Remove the sharklet strobe light (Ref. AMM TASK 33-48-14-000-001).
C. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the wing tip.
(2) For the left wing:
(a) Remove access panels 534BB and 534CB (Ref. AMM TASK 57-31-23-000-802).
(3) For the right wing:
(a) Remove access panels 634BB and 634CB (Ref. AMM TASK 57-31-23-000-802).
(4) Remove wing-tip navigation light 9LA (10LA) (Ref. AMM TASK 33-41-11-000-802).
(5) Remove the sharklet strobe light (Ref. AMM TASK 33-48-14-000-802).
4. Procedure(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the wing tip.
(2) For the left wing:
(a) Remove access panels 534BB and 534CB (Ref. AMM TASK 57-31-23-000-802).
(3) For the right wing:
(a) Remove access panels 634BB and 634CB (Ref. AMM TASK 57-31-23-000-802).
(4) Remove wing-tip navigation light 9LA (10LA) (Ref. AMM TASK 33-41-11-000-802).
(5) Remove the sharklet strobe light (Ref. AMM TASK 33-48-14-000-802).
Subtask 24-92-00-210-054-A
A. Temporary Protection of the Electrical Conduits End-Fittings in the Wing Tip
Location of the Electrical Conduit End-Fittings ** ON A/C NOT FOR ALL
Location of the Electrical Conduit End-Fittings ** ON A/C NOT FOR ALL
(a) Remove contamination from the fitting with the Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
(b) Remove the flakes or blisters and make sure that the you do not damage the base metal while you do this task.
5. Close-up
Location of the Electrical Conduit End-Fittings ** ON A/C NOT FOR ALL
Location of the Electrical Conduit End-Fittings ** ON A/C NOT FOR ALL WARNING:
BE CAREFUL NOT TO CUT YOUR FINGERS. FLAKES OF NICKEL ARE SHARP.
(1) To prevent corrosion, do the steps that follow at each fitting: (a) Remove contamination from the fitting with the Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
(b) Remove the flakes or blisters and make sure that the you do not damage the base metal while you do this task.
NOTE: We recommend that you use a dental tool or a seal tool (non metallic) to remove the flakes and the blisters.
(c) Apply a continuous thin and smooth layer of Corrosion Preventive Compound-Heavy Duty Hard Film - (Material No.12ACB1) on all the fittings with the BRUSH - BRISTLED or the SPRAY - BOTTLE, PUMP TYPE (NON AEROSOL) ESPM 203330.Subtask 24-92-00-410-055-B ** ON A/C NOT FOR ALL
A. Close Access
(1) Install the sharklet strobe light (Ref. AMM TASK 33-48-14-400-001).
(2) Install wing-tip navigation light 9LA (10LA) (Ref. AMM TASK 33-41-11-400-001).
(3) Make sure that the work area is clean and clear of tools and other items.
(4) For the left wing:
(a) Install access panel 534AB.
(b) Make sure that access panel 534AB is installed with the drain holes in the inboard direction (Ref. AMM D/O 57-39-00-00).
(5) For the right wing:
(a) Install access panel 634AB.
(b) Make sure that access panel 634AB is installed with the drain holes in the inboard direction (Ref. AMM D/O 57-39-00-00).
(6) Disconnect the aircraft from the ground (Ref. AMM TASK 12-34-24-869-002).
(7) Remove the access platform(s).
Subtask 24-92-00-410-055-C ** ON A/C NOT FOR ALL (1) Install the sharklet strobe light (Ref. AMM TASK 33-48-14-400-001).
(2) Install wing-tip navigation light 9LA (10LA) (Ref. AMM TASK 33-41-11-400-001).
(3) Make sure that the work area is clean and clear of tools and other items.
(4) For the left wing:
(a) Install access panel 534AB.
(b) Make sure that access panel 534AB is installed with the drain holes in the inboard direction (Ref. AMM D/O 57-39-00-00).
(5) For the right wing:
(a) Install access panel 634AB.
(b) Make sure that access panel 634AB is installed with the drain holes in the inboard direction (Ref. AMM D/O 57-39-00-00).
(6) Disconnect the aircraft from the ground (Ref. AMM TASK 12-34-24-869-002).
(7) Remove the access platform(s).
A. Close Access
(1) Install the sharklet strobe light (Ref. AMM TASK 33-48-14-400-802).
(2) Install wing-tip navigation light 9LA (10LA) (Ref. AMM TASK 33-41-11-400-802).
(3) Make sure that the work area is clean and clear of tools and other items.
(4) For the left wing:
(a) Install access panels 534BB and 534CB (Ref. AMM TASK 57-31-23-400-802).
(5) For the right wing:
(a) Install access panels 634BB and 634CB (Ref. AMM TASK 57-31-23-400-802).
(6) Disconnect the aircraft from the ground (Ref. AMM TASK 12-34-24-869-002).
(7) Remove the access platform(s).
(1) Install the sharklet strobe light (Ref. AMM TASK 33-48-14-400-802).
(2) Install wing-tip navigation light 9LA (10LA) (Ref. AMM TASK 33-41-11-400-802).
(3) Make sure that the work area is clean and clear of tools and other items.
(4) For the left wing:
(a) Install access panels 534BB and 534CB (Ref. AMM TASK 57-31-23-400-802).
(5) For the right wing:
(a) Install access panels 634BB and 634CB (Ref. AMM TASK 57-31-23-400-802).
(6) Disconnect the aircraft from the ground (Ref. AMM TASK 12-34-24-869-002).
(7) Remove the access platform(s).