Removal of the Strobe Light
TASK 33-48-14-000-001-A
Removal of the Strobe Light
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 33-48-14-941-050-A ** ON A/C NOT FOR ALL
Subtask 33-48-14-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 05:54:28 UTC
Removal of the Strobe Light
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
WARNING:
DO NOT TOUCH THE STROBE LIGHTS FOR AT LEAST 5 MINUTES AFTER OPERATION. THE STROBE LIGHT WILL STILL BE HOT.
WARNING:
DO NOT REMOVE THE STROBE LIGHT FOR AT LEAST TEN MINUTES AFTER YOU DE-ENERGIZE THE ELECTRICAL CIRCUITS. THE HIGH VOLTAGE ELECTRICAL CURRENT IN THE CAPACITOR OF THE STROBE LIGHT IS DANGEROUS.
1. Reason for the JobSelf Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 57-37-12-000-802-A | Removal of the Navigation-Light Glazing Panel |
Subtask 33-48-14-941-050-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Put the SAFETY BARRIER(S) in position.
(2) Put a WARNING NOTICE(S) in the cockpit on panel 25VU to tell persons not to operate the navigation lights or the strobe lights.
Subtask 33-48-14-865-050-A ** ON A/C NOT FOR ALL (1) Put the SAFETY BARRIER(S) in position.
(2) Put a WARNING NOTICE(S) in the cockpit on panel 25VU to tell persons not to operate the navigation lights or the strobe lights.
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 33-48-14-010-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 122VU | LIGHTING/WING/STROBE | 10LV | V05 |
C. Get Access
(1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position below the applicable zone 534 or 634.
(2) Remove the applicable glazing panel (3) (Ref. AMM TASK 57-37-12-000-802).
4. Procedure(1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position below the applicable zone 534 or 634.
(2) Remove the applicable glazing panel (3) (Ref. AMM TASK 57-37-12-000-802).
Subtask 33-48-14-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Strobe Light
(2) Remove the strobe light sufficiently to get access to the electrical connector (1).
(3) Disconnect the electrical connector (1).
(4) Remove the strobe light (2).
(5) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
WARNING:
DO NOT DISCONNECT THE ELECTRICAL CONNECTIONS FOR AT LEAST 2 MINUTES AFTER YOU DE-ENERGIZE THE ELECTRICAL CIRCUITS.
(1) Remove the bolts (4) and the washers (5). (2) Remove the strobe light sufficiently to get access to the electrical connector (1).
(3) Disconnect the electrical connector (1).
(4) Remove the strobe light (2).
(5) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
Strobe Light