Cleaning of EWIS Installed in the Forward Cabin Overhead-Compartment (Only If Contaminated)(EWIS)
TASK 24-92-00-100-010-A
Cleaning of EWIS Installed in the Forward Cabin Overhead-Compartment (Only If Contaminated)(EWIS)
1. Reason for the Job
Refer to the MPD TASK: 200223-01
CLEANING OF EWIS INSTALLED IN THE FORWARD CABIN OVERHEAD COMPARTMENT (ONLY IF CONTAMINATED) (EWIS)
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 24-92-00-010-103-A
Subtask 24-92-00-160-059-A
Subtask 24-92-00-410-101-A
[Rev.10 from 2021]
2026.03.31 23:27:08 UTC
Cleaning of EWIS Installed in the Forward Cabin Overhead-Compartment (Only If Contaminated)(EWIS)
1. Reason for the Job
Refer to the MPD TASK: 200223-01
CLEANING OF EWIS INSTALLED IN THE FORWARD CABIN OVERHEAD COMPARTMENT (ONLY IF CONTAMINATED) (EWIS)
NOTE: This is an EWIS (Electrical Wiring Interconnection System) procedure. EWIS is defined in ESPM 20-33-11.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 223 | FWD CAB OVERHEAD COMPARTMENT |
| 224 | FWD CAB OVERHEAD COMPARTMENT |
| 221AC, 221BC, 222BC |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 25-23-42-000-001-A | Removal of the Ceiling Panels - Forward Utility Area |
| TASK 25-23-42-400-001-A | Installation of the Ceiling Panels - Forward Utility Area |
| TASK 25-31-41-000-001-A | Removal of the Forward Galley Unit |
| TASK 25-31-41-400-001-A | Installation of the Forward Galley Unit |
| TASK 25-31-42-000-001-A | Removal of the Forward Galley Unit |
| TASK 25-31-42-400-001-A | Installation of the Forward Galley Unit |
| TASK 25-41-41-000-001-A | Removal of Lavatory A |
| TASK 25-41-41-000-001-B | Removal of Lavatory A |
| TASK 25-41-41-400-001-A | Installation of Lavatory A |
| TASK 25-41-41-400-001-B | Installation of Lavatory A |
| TASK 52-10-00-010-001-A | Opening of the Passenger/Crew Door |
| TASK 52-10-00-410-001-A | Closing of the Passenger/Crew Door |
| ESPM 2055000 | |
Subtask 24-92-00-010-103-A
A. Get Access
(1) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position at the zone 831 (841).
(2) Open the forward passenger/crew door 831 (841) (Ref. AMM TASK 52-10-00-010-001).
(3) Remove the ceiling panels in the forward utility area (Ref. AMM TASK 25-23-42-000-001):
(4) Remove the lavatory A (Ref. AMM TASK 25-41-41-000-001) or stowage (Ref. AMM D/O 25-27-44-00) if installed.
(5) Remove the forward galley unit (6475MM) (Ref. AMM TASK 25-31-41-000-001) or (Ref. AMM TASK 25-31-42-000-001) if installed.
Subtask 24-92-00-862-091-A 4. Procedure(1) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position at the zone 831 (841).
(2) Open the forward passenger/crew door 831 (841) (Ref. AMM TASK 52-10-00-010-001).
(3) Remove the ceiling panels in the forward utility area (Ref. AMM TASK 25-23-42-000-001):
(4) Remove the lavatory A (Ref. AMM TASK 25-41-41-000-001) or stowage (Ref. AMM D/O 25-27-44-00) if installed.
(5) Remove the forward galley unit (6475MM) (Ref. AMM TASK 25-31-41-000-001) or (Ref. AMM TASK 25-31-42-000-001) if installed.
Subtask 24-92-00-160-059-A
A. Cleaning of All Wiring Installed in the Forward Cabin Overhead-Compartment (Only Contaminated Wiring)
(1) Clean the wiring if there is dust contamination ESPM 2055000.
(a) On the AC/DC feeder routes: 3G and 6G.
(b) On the AC/DC power-distribution routes: 1P, 2P and 3P.
(c) On the generator excitation routes: 3E and 6E.
(d) On other routes: 1M and 2M.
5. Close-up(1) Clean the wiring if there is dust contamination ESPM 2055000.
(a) On the AC/DC feeder routes: 3G and 6G.
(b) On the AC/DC power-distribution routes: 1P, 2P and 3P.
(c) On the generator excitation routes: 3E and 6E.
(d) On other routes: 1M and 2M.
Subtask 24-92-00-410-101-A
A. Close Access
(1) Install the ceiling panels in the forward utility area (Ref. AMM TASK 25-23-42-400-001).
(2) Install the forward galley unit (6475MM) (Ref. AMM TASK 25-31-41-400-001) or (Ref. AMM TASK 25-31-42-400-001) if removed.
(3) Install the lavatory A (Ref. AMM TASK 25-41-41-400-001) or stowage (Ref. AMM D/O 25-27-44-40) if removed.
(4) Close the forward passenger/crew door 831 (841) (Ref. AMM TASK 52-10-00-410-001).
(5) Remove the access platform(s).
(1) Install the ceiling panels in the forward utility area (Ref. AMM TASK 25-23-42-400-001).
(2) Install the forward galley unit (6475MM) (Ref. AMM TASK 25-31-41-400-001) or (Ref. AMM TASK 25-31-42-400-001) if removed.
(3) Install the lavatory A (Ref. AMM TASK 25-41-41-400-001) or stowage (Ref. AMM D/O 25-27-44-40) if removed.
(4) Close the forward passenger/crew door 831 (841) (Ref. AMM TASK 52-10-00-410-001).
(5) Remove the access platform(s).
Forward Cabin Overhead-Compartment - Cleaning Area - Zones 223-224