Functional Test of the Cockpit and Cabin Temperature Control without CFDS/MCDU.


TASK 21-63-00-720-001-A
Functional Test of the Cockpit and Cabin Temperature Control without CFDS/MCDU.


1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 12-33-21-618-001-A-01
Pre-conditioning through the HP Ground Connection
TASK 12-33-21-618-001-A-02
Pre-conditioning with the APU
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 31-60-00-860-001-A
EIS Start Procedure
TASK 31-60-00-860-002-A
EIS Stop Procedure
3. Job Set-up
Subtask 21-63-00-861-062-A
A. Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
Subtask 21-63-00-865-063-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/FLOW/CTL &/IND11HBD07
** ON A/C NOT FOR ALL
49VUAIR COND/TEMP CTL/SYS 1 CHAN B/28VDC52HHD08
** ON A/C NOT FOR ALL
122VUAIR COND/FLOW/MIXER/FLAP3HBV22
122VUAIR COND/FLOW/CTL AND IND/22HBV21
122VUAIR COND/ZONE TEMP CTL/28VDC/SYS24HKV20
122VUAIR COND/ZONE TEMP CTL/28VDC/SYS13HKV19
122VUAIR COND/ZONE TEMP CTL/115VAC/SYS22HKV18
122VUAIR COND/ZONE TEMP CTL/115VAC/SYS11HKV17
122VUAIR COND/PACK TEMP/CTL SYS1/2/115VAC21HHW22
122VUAIR COND/PACK TEMP/CTL SYS1/2/28VDC23HHW21
122VUAIR COND/PACK TEMP/CTL SYS1/1/115VAC1HHX22
122VUAIR COND/PACK TEMP/CTL SYS1/1/28VDC3HHX21
122VUAIR COND/PACK TEMP CTL SYS2/2/28VDC24HHY21
122VUAIR COND/PACK TEMP CTL SYS2/2/115VAC22HHY20
122VUAIR COND/PACK TEMP CTL SYS2/1/28VDC4HHY19
122VUAIR COND/PACK TEMP CTL SYS2/1/115VAC2HHY18
** ON A/C NOT FOR ALL
122VUAIR COND/TEMP CTL SYS 2/CHAN A/115VAC53HHW22
122VUAIR COND/TEMP CTL SYS 2/CHAN A/28VDC55HHW21
122VUAIR COND/TEMP CTL SYS 1/CHAN A/115VAC49HHX22
122VUAIR COND/TEMP CTL SYS 1/CHAN A/28VDC51HHX21
122VUAIR COND/TEMP CTL SYS 2/CHAN B/28VDC56HHY21
122VUAIR COND/TEMP CTL SYS 2/CHAN B/115VAC54HHY20
122VUAIR COND/TEMP CTL SYS 1/CHAN B/115VAC50HHY18
Subtask 21-63-00-860-054-A ** ON A/C NOT FOR ALL
C. Aircraft Maintenance Configuration
WARNING: MAKE SURE THAT THE FWD AVIONICS ACCESS DOOR 811 IS OPEN WITH A WARNING PLACARD ATTACHED TO IT. THE WARNING NOTICE MUST TELL PERSONS NOT TO CLOSE THE DOOR. THIS PREVENTS ACCIDENTAL PRESSURIZATION OF THE AIRCRAFT.
   (1) Pre-condition the Aircraft
   (2) On the AIR COND panel 30VU make sure that:
     (a) the PACK FLOW selector is in the NORM position and,
     (b) the PACK 1 and the PACK 2 pushbutton switches are in the on position (the OFF legend is off).
   (3) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
Subtask 21-63-00-860-054-B ** ON A/C NOT FOR ALL
C. Aircraft Maintenance Configuration
WARNING: MAKE SURE THAT THE FWD AVIONICS ACCESS DOOR 811 IS OPEN WITH A WARNING PLACARD ATTACHED TO IT. THE WARNING NOTICE MUST TELL PERSONS NOT TO CLOSE THE DOOR. THIS PREVENTS ACCIDENTAL PRESSURIZATION OF THE AIRCRAFT.
   (1) Pre-condition the Aircraft
   (2) On the AIR COND panel 30VU make sure that:
     (a) the ECON FLOW pushbutton switch is in the off position (the ON legend is off) and,
     (b) the PACK 1 and the PACK 2 pushbutton switches are in the on position (the OFF legends are off).
   (3) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
4. Procedure
Subtask 21-63-00-720-050-B
WARNING: MAKE SURE THAT THERE ARE NO PERSONS OR EQUIPMENT NEAR THE RAM AIR OUTLETS. HOT EXHAUST GASES CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
A. Functional Test of the Temperature Control System
NOTE: Make sure that the cabin doors and the cockpit windows are closed when you do the test.
NOTE: Due to low pressure in the trim system, with fully closed trim air valves the trim-air pressure regulating-valve symbol (6) can be indicated as closed and show amber.
You must ignore this indication for the purposes of this test.
ACTION
RESULT
1.On the ECAM control panel:
  • push the BLEED pushbutton switch.
On the System Display (SD):
  • the BLEED page comes on,
  • the pack flow-control valves symbols (1) move to the open positions and show green.
2.On the AIR COND panel 30VU:
  • put the COCKPIT, the FWD CABIN and the AFT CABIN temperature selectors to the mid (12 o'clock) position ( 24 deg.C (75.20 deg.F)).

3.On the ECAM control panel:
  • push the COND pushbutton switch.
On the SD:
  • the COND page comes on.
4.Wait until the CKPT, the FWD and the AFT zone temperatures (5) have stabilized at 24 deg.C (75.20 deg.F).
On the SD (COND page):
  • the CKPT, the FWD and the AFT zone temperatures (5) are shown in green.
5.On the AIR COND panel 30VU:
  • put the COCKPIT, the FWD CABIN and the AFT CABIN temperature selectors to the HOT position ( 30 deg.C (86.00 deg.F)).
On the SD (COND page):
  • the trim-air pressure regulating-valves symbols (6) show green and open.
  • the CKPT, the FWD and the AFT zone temperatures (5) start to increase.
  • the trim-air valves position needles (4) show green and open to a maximum of 80%, then start to close,
    if the target temperature is reached, or
    if the duct temperature limits are reached.
6.On the ECAM control panel:
  • push the BLEED pushbutton switch.
On the SD:
  • the BLEED page comes on,
  • the temperature control valves position needles (2) show green and move to the open (H) positions,
  • the pack outlet temperatures (3) show a maximum of 70 deg.C (158.00 deg.F).
7.On the AIR COND panel 30VU:
  • put the COCKPIT, the FWD CABIN and the AFT CABIN temperature selectors to the COLD position ( 18 deg.C (64.40 deg.F)) and wait for apprx. 3 minutes.
On the SD (BLEED page):
  • the temperature control valves position needles (2) show green and move to the closed (C) positions,
  • the pack outlet temperatures (3) decrease,
    (the lowest pack outlet temperatures reached are dependant upon the outside air temperature).
8.On the ECAM control panel:
  • push the COND pushbutton switch.
On the SD:
  • the COND page comes on,
    If the actual temperature is more than the selected temperature, or the duct temperatures are more than the allowed lower duct temperatures then,
  • the trim air valves position needles (4) show green and move to the closed (C) positions,
  • the CKPT, the FWD and the AFT zone temperatures (5) decrease.
5. Close-up
Subtask 21-63-00-860-055-A
A. Aircraft Maintenance Configuration
   (1) On the AIR COND panel 30VU put the cockpit and the cabin TEMP selectors to the 12 o'clock position.
   (2) Push the PACK 1 and the PACK 2 pushbutton switches to the off position (the OFF legends are on).
   (3) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
   (4) Stop the pre-conditioning with the APU (Ref. AMM TASK 12-33-21-618-001) or through the HP ground connector (Ref. AMM TASK 12-33-21-618-001) .
Subtask 21-63-00-862-061-A
B. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).