Operational Test of the Flow Control Valves Closing
TASK 21-51-00-710-003-A
Operational Test of the Flow Control Valves Closing
Self explanatory
2. Job Set-up Information
A. Referenced Information
3. Job Set-up
Subtask 21-51-00-861-053-A Subtask 21-51-00-865-053-A
Subtask 21-51-00-860-054-A
[Rev.10 from 2021]
2026.04.01 08:26:22 UTC
Operational Test of the Flow Control Valves Closing
WARNING:
MAKE SURE THAT THE FWD AVIONICS ACCESS DOOR 811 IS OPEN WITH A WARNING PLACARD ATTACHED TO IT.
THE WARNING NOTICE MUST TELL PERSONS NOT TO CLOSE THE DOOR. THIS PREVENTS ACCIDENTAL PRESSURIZATION OF THE AIRCRAFT.
FIN: 11HB ** ON A/C NOT FOR ALL
FIN: 23HB ** ON A/C NOT FOR ALL
FIN: 24HB ** ON A/C NOT FOR ALL
FIN: 8HB ** ON A/C NOT FOR ALL
1. Reason for the JobFIN: 23HB ** ON A/C NOT FOR ALL
FIN: 24HB ** ON A/C NOT FOR ALL
FIN: 8HB ** ON A/C NOT FOR ALL
Self explanatory
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-33-21-618-001-A-01 | Pre-conditioning through the HP Ground Connection |
| TASK 12-33-21-618-001-A-02 | Pre-conditioning with the APU |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 31-60-00-860-002-A | EIS Stop Procedure |
Subtask 21-51-00-861-053-A Subtask 21-51-00-865-053-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 21-51-00-860-053-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/TEMP CTL/SYS 1 CHAN B/28VDC | 52HH | D08 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/ZONE TEMP CTL/28VDC/SYS2 | 4HK | V20 |
| 122VU | AIR COND/ZONE TEMP CTL/28VDC/SYS1 | 3HK | V19 |
| 122VU | AIR COND/ZONE TEMP CTL/115VAC/SYS2 | 2HK | V18 |
| 122VU | AIR COND/ZONE TEMP CTL/115VAC/SYS1 | 1HK | V17 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/2/115VAC | 21HH | W22 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/2/28VDC | 23HH | W21 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/1/115VAC | 1HH | X22 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/1/28VDC | 3HH | X21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/2/28VDC | 24HH | Y21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/2/115VAC | 22HH | Y20 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/1/28VDC | 4HH | Y19 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/1/115VAC | 2HH | Y18 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN A/115VAC | 53HH | W22 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN A/28VDC | 55HH | W21 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN A/115VAC | 49HH | X22 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN A/28VDC | 51HH | X21 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN B/28VDC | 56HH | Y21 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN B/115VAC | 54HH | Y20 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN B/115VAC | 50HH | Y18 |
C. Aircraft Maintenance Configuration
(1) Open the avionics-bay access door 811.
(2) Put a warning notice in position to tell persons not to close the avionics-bay access door 811.
(3) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
(4) Make sure that the BLEED page is shown on the ECAM lower display unit.
(5) On the panel 30VU make sure that:
Subtask 21-51-00-860-053-B ** ON A/C NOT FOR ALL (1) Open the avionics-bay access door 811.
(2) Put a warning notice in position to tell persons not to close the avionics-bay access door 811.
(3) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
(4) Make sure that the BLEED page is shown on the ECAM lower display unit.
(5) On the panel 30VU make sure that:
- the PACK 1 and the PACK 2 pushbutton switches are in the off position (the OFF legends are on),
- the PACK FLOW selector is in the NORM position and,
- the HOT AIR pushbutton switch is in the off position (the OFF legend is on).
C. Aircraft Maintenance Configuration
(1) Open the avionics-bay access door 811.
(2) Put a warning notice in position to tell persons not to close the avionics-bay access door 811.
(3) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
(4) Make sure that the BLEED page is shown on the ECAM lower display unit.
(5) On the panel 30VU make sure that:
Subtask 21-51-00-618-051-A (1) Open the avionics-bay access door 811.
(2) Put a warning notice in position to tell persons not to close the avionics-bay access door 811.
(3) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
(4) Make sure that the BLEED page is shown on the ECAM lower display unit.
(5) On the panel 30VU make sure that:
- the PACK 1 and the PACK 2 pushbutton switches are in the off position (the OFF legends are on),
- the ECON FLOW pushbutton switch is in the off position (the ON legend is off) and,
- the HOT AIR pushbutton switch is in the off position (the OFF legend is on).
D. Do the pre-conditioning through the HP ground connection (Ref. AMM TASK 12-33-21-618-001) or with the APU (Ref. AMM TASK 12-33-21-618-001).
4. ProcedureWARNING:
MAKE SURE THAT THERE ARE NO PERSONS OR EQUIPMENT NEAR THE RAM AIR OUTLETS.
HOT EXHAUST GASES CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
Subtask 21-51-00-710-052-A A. Operational Test of the Flow Control Valves Closing
5. Close-up| ACTION | RESULT |
|---|---|
1.On the panel 30VU:
| On the panel 30VU:
|
| | On the ECAM lower display unit:
|
| On the panel 30VU:
|
| | On the ECAM lower display panel:
|
Subtask 21-51-00-860-054-A
A. Aircraft Maintenance Configuration
(1) Stop the pre-conditioning through the HP ground connection (Ref. AMM TASK 12-33-21-618-001).
(2) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
(3) Remove the WARNING NOTICE(S).
(4) Close the avionics-bay access door 811.
Subtask 21-51-00-862-052-A (1) Stop the pre-conditioning through the HP ground connection (Ref. AMM TASK 12-33-21-618-001).
(2) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
(3) Remove the WARNING NOTICE(S).
(4) Close the avionics-bay access door 811.