W DOC AIRBUS | AMM A320F

Installation of the Oil Quantity Transmitter [CFMI]


TASK 79-31-15-400-040-A
Installation of the Oil Quantity Transmitter


FIN: 4002EN ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
WARNING NOTICE(S)
No specific
Torque wrench: range to between 70 and 63 lbf.in (0.79 and 0.71 m.daN ) T
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.CP2442)
engine oil
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL
FOR [1000EM2] (ENGINE-2)
447AL
 D. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
25
PACKING
AIPC 79-31-15-01-040
20
PACKING
AIPC 79-31-15-01-051
 E. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 31-60-00-860-001-A
EIS Start Procedure
TASK 31-60-00-860-002-A
EIS Stop Procedure
TASK 71-13-00-010-040-A
Opening of the Fan Cowl Doors
TASK 71-13-00-410-040-A
Closing of the Fan Cowl Doors
3. Job Set-up
Subtask 79-31-15-860-054-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) On the center pedestal, on the ENG panel 115VU, make sure that a WARNING NOTICE(S) is in position to tell persons not to start the engine.
   (2) On the overhead maintenance panel 50VU, make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off. Make sure that a WARNING NOTICE(S) is in position to tell persons not to energize the FADEC 1(2).
Subtask 79-31-15-010-055-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Make sure that the left fan cowl doors is open (Ref. AMM TASK 71-13-00-010-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL
     (b) FOR [1000EM2] (ENGINE-2)
447AL
4. Procedure
Subtask 79-31-15-420-052-A ** ON A/C NOT FOR ALL Subtask 79-31-15-861-051-A ** ON A/C NOT FOR ALL Subtask 79-31-15-860-056-A ** ON A/C NOT FOR ALL
C. Do the EIS start procedure (lower ECAM DU only) (Ref. AMM TASK 31-60-00-860-001).
Subtask 79-31-15-869-054-A ** ON A/C NOT FOR ALL
D. Make sure that oil quantity indication is available on the lower ECAM DU.
Subtask 79-31-15-860-055-A ** ON A/C NOT FOR ALL
E. Do the EIS stop procedure (Ref. AMM TASK 31-60-00-860-002).
Subtask 79-31-15-862-051-A ** ON A/C NOT FOR ALL
F. De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
5. Close-up
Subtask 79-31-15-410-052-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the left fan cowl door (Ref. AMM TASK 71-13-00-410-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL
     (b) FOR [1000EM2] (ENGINE-2)
447AL
   (3) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 03:38:21 UTC