Installation of the Generator Power Harness 238W0903 [CFMI]


TASK 71-51-44-400-001-A
Installation of the Generator Power Harness 238W0903


FIN: 1000EM1 ** ON A/C NOT FOR ALL
FIN: 1000EM2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 1M(3 FT)
No specific
1
GROUND AIR-SUPPLY UNIT(HIGH PRESSURE)
No specific
AR
WARNING NOTICE(S)
No specific
Torque wrench: range to between 14 and 12 lbf.ft (1.90 and 1.63 m.daN ) T
No specific
Torque wrench: range to between 22 and 20 lbf.in (0.25 and 0.23 m.daN ) T
No specific
Torque wrench: range to between 25 and 20 lbf.in (0.28 and 0.23 m.daN ) T
No specific
Torque wrench: range to between 110 and 95 lbf.in (1.24 and 1.07 m.daN ) T
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.CP1041)
isopropyl alcohol
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 31-60-00-860-001-A
EIS Start Procedure
TASK 31-60-00-860-002-A
EIS Stop Procedure
TASK 70-60-00-910-042-A
Nacelle Standard Practices
TASK 71-00-00-710-003-A
Engine Automatic Start
TASK 71-00-00-710-028-A
Engine Shutdown
TASK 71-13-00-010-040-A
Opening of the Fan Cowl Doors
TASK 71-13-00-410-040-A
Closing of the Fan Cowl Doors
3. Job Set-up
Subtask 71-51-44-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) On the center pedestal, on the ENG panel 115VU, make sure that a WARNING NOTICE(S) is in position to tell persons not to start the engine.
   (2) On the overhead maintenance panel 50VU, make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off. Make sure that a WARNING NOTICE(S) is in position to tell persons not to energize the FADEC 1(2).
   (3) Make sure that the ACCESS PLATFORM 1M(3 FT) is in position.
Subtask 71-51-44-010-051-A ** ON A/C NOT FOR ALL
B. Make sure that the fan cowl doors are open (Ref. AMM TASK 71-13-00-010-040):
   (1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
   (2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
Subtask 71-51-44-865-051-A ** ON A/C NOT FOR ALL
WARNING: OPEN THE PROBE HEATER CIRCUIT-BREAKERS 1DA1(2), 3DA1(2,3), 4DA1(2,3) AND 5DA1(2,3) BEFORE ENG1(2)FADEC A and EIU 1(2) C/B'S 2KS1 AND 2KS2. IF YOU DO NOT OBEY THIS SEQUENCE:
  • THE PROBES WILL BECOME TOO HOT.
  • THIS CAN CAUSE DAMAGE TO EQUIPMENT AND INJURY TO MAINTENANCE PERSONNEL.
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUENGINE/1 AND 2/IGN/SYS A1JHA03
49VUANTI ICE/PROBES/AOA/14DA1D04
49VUANTI ICE/PROBES/PITOT/13DA1D02
49VUCOM/CVR/SPLY2RKE14
49VUCOM/CVR/CTL4RKE13
121VURCDR/DFDR7TUK16
121VUHYDRAULIC/HYD POWER/Y3803GXN30
122VUANTI ICE/WINDOWS/R4DG2W14
122VUANTI ICE/WINDOWS/L4DG1X14
122VUANTI ICE/PROBES/2/PITOT3DA2Y14
122VUANTI ICE/PROBES/2/AOA4DA2Y13
122VUANTI ICE/PROBES/2/STATIC5DA2Y11
122VUANTI ICE/PROBES/3/PITOT3DA3Z16
122VUANTI ICE/PROBES/3/AOA4DA3Z15
122VUANTI ICE/PROBES/3/STATIC5DA3Z14
122VUANTI ICE/PROBES/1/STATIC5DA1Z13
123VUY HYD/ELEC/PUMP3802GXAB06
123VUY HYD/ELEC/ELEC PUMP/NORM3801GXAB03
FOR FIN: 1000EM1 (ENGINE1)
49VUENGINE/1/FIRE DET/LOOP A7WD1A06
49VUENGINE/1/FADEC A/AND EIU 12KS1A04
121VUENGINE/IGN/ENG1/SYS B3JH1P41
121VUENGINE/IGN/ENG1/SYS A BAT2JH1P39
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/B2WE1Q44
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/A1WE1Q43
121VUENGINE/ENG1/FIRE DET/LOOP B8WD1Q38
121VUENGINE/ENG1/FADEC B/AND EIU 14KS1R41
122VUELEC/GCU/12XU1T26
FOR FIN: 1000EM2 (ENGINE2)
49VUENGINE/2/FIRE DET/LOOP B8WD2A07
49VUENGINE/2/FADEC A/AND EIU 22KS2A05
121VUENGINE/IGN/ENG2/SYS B3JH2P42
121VUENGINE/IGN/ENG2/SYS A BAT2JH2P40
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/B2WE2Q42
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/A1WE2Q41
121VUENGINE/ENG2/FADEC B4KS2Q40
121VUENGINE/ENG2/FIRE DET/LOOP A7WD2Q39
122VUELEC/GCU/22XU2T27
4. Procedure
Subtask 71-51-44-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the Generator Power Harness 238W09036
NOTE: Refer to the recommended procedure for the installation of the wire harness (Ref. AMM TASK 70-60-00-910-042).
   (1) Remove the protective covers from the electrical connectors on the harness (5) and the pylon junction box.
   (2) Make sure that all the electrical connections are clean and in the correct condition.
   (3) Do not clean the contacts with abrasive material.
   (4) Do a pin retention check of the sockets (Ref. AWM 20-44-14).
   (5) Put the electrical harness (5) in position on the engine.
   (6) Connect the electrical connector 400VC-A to the pylon junction box.
     (a) Tighten the connector by hand until the colored marking is visible in the lock display (window).
   (7) Put the harness (5) into the flip-lock clamps (10).
   (8) Tighten the captive screws 1/4 turn clockwise to engage the cam nuts.
   (9) Cleaning of the mating surfaces:
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
     (a) Clean the mating surfaces of the ground cable terminals and the ground plate with isopropyl alcohol (Material No.CP1041) and a Textile-Lint free Cotton - (Material No.14SBA1) .
   (10) Attach the harness cables (5) to the ground plate with the bolt (15), the washer (20), the lockwasher (25) and the nut (30). Remove the tags.
   (11) TORQUE the nut (30) to between 110 and 95 lbf.in (1.24 and 1.07 m.daN ) T.
   (12) Attach the ground cables (60), (65), (120) and (125) to the IDG terminals with the washers (55), the lockwashers (50), and the nuts (45).
   (13) TORQUE the nuts (45) to between 14 and 12 lbf.ft (1.90 and 1.63 m.daN )
T.
   (14) Install the cover (40) on the IDG terminal with the screws (35).
   (15) TORQUE the screws (35) to between 22 and 20 lbf.in (0.25 and 0.23 m.daN )
T.
   (16) Attach the bracket (85) to the line block (80) with the bolt (95), the washers (90) and (75), and nut (70).
   (17) TORQUE the nut (70) to between 25 and 20 lbf.in (0.28 and 0.23 m.daN )
T.
   (18) Attach the clamp (110) to the bracket (85) with the screw (105), the washer (100) and the nut (115).
   (19) TORQUE the nut (115) to between 25 and 20 lbf.in (0.28 and 0.23 m.daN )
T.
   (20) Examine the harness installation and make sure that all clamps and line blocks are installed correctly.
Subtask 71-51-44-760-050-A ** ON A/C NOT FOR ALL
B. Do an electrical bond resistance check as follows:
NOTE: The electrical bond resistance procedure that follows is applicable for the electrical harness ground cables.
   (1) Put one lead of the ohmmeter on the ground cable terminal near the bolt (15).
   (2) Put the other lead of the ohmmeter on the top surface of the bracket.
   (3) The resistance measured between the ohmmeter leads must not be more than 0.001 ohm.
   (4) If the resistance is more than 0.001 ohm, remove the applicable hardware and clean the mating surface again. Do this procedure until the resistance is less than 0.001 ohm.
Subtask 71-51-44-865-052-A ** ON A/C NOT FOR ALL
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUENGINE/1 AND 2/IGN/SYS A1JHA03
49VUANTI ICE/PROBES/AOA/14DA1D04
49VUANTI ICE/PROBES/PITOT/13DA1D02
49VUCOM/CVR/SPLY2RKE14
49VUCOM/CVR/CTL4RKE13
121VURCDR/DFDR7TUK16
121VUHYDRAULIC/HYD POWER/Y3803GXN30
122VUANTI ICE/WINDOWS/R4DG2W14
122VUANTI ICE/WINDOWS/L4DG1X14
122VUANTI ICE/PROBES/2/PITOT3DA2Y14
122VUANTI ICE/PROBES/2/AOA4DA2Y13
122VUANTI ICE/PROBES/2/STATIC5DA2Y11
122VUANTI ICE/PROBES/3/PITOT3DA3Z16
122VUANTI ICE/PROBES/3/AOA4DA3Z15
122VUANTI ICE/PROBES/3/STATIC5DA3Z14
122VUANTI ICE/PROBES/1/STATIC5DA1Z13
123VUY HYD/ELEC/PUMP3802GXAB06
123VUY HYD/ELEC/ELEC PUMP/NORM3801GXAB03
FOR FIN: 1000EM1 (ENGINE1)
49VUENGINE/1/FIRE DET/LOOP A7WD1A06
49VUENGINE/1/FADEC A/AND EIU 12KS1A04
121VUENGINE/IGN/ENG1/SYS B3JH1P41
121VUENGINE/IGN/ENG1/SYS A BAT2JH1P39
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/B2WE1Q44
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/A1WE1Q43
121VUENGINE/ENG1/FIRE DET/LOOP B8WD1Q38
121VUENGINE/ENG1/FADEC B/AND EIU 14KS1R41
122VUELEC/GCU/12XU1T26
FOR FIN: 1000EM2 (ENGINE2)
49VUENGINE/2/FIRE DET/LOOP B8WD2A07
49VUENGINE/2/FADEC A/AND EIU 22KS2A05
121VUENGINE/IGN/ENG2/SYS B3JH2P42
121VUENGINE/IGN/ENG2/SYS A BAT2JH2P40
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/B2WE2Q42
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/A1WE2Q41
121VUENGINE/ENG2/FADEC B4KS2Q40
121VUENGINE/ENG2/FIRE DET/LOOP A7WD2Q39
122VUELEC/GCU/22XU2T27
Subtask 71-51-44-861-050-A ** ON A/C NOT FOR ALL
Subtask 71-51-44-869-050-A ** ON A/C NOT FOR ALL
E. Aircraft Maintenance Configuration
   (1) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
   (2) Pressurize the aircraft pneumatic system with a GROUND AIR-SUPPLY UNIT(HIGH PRESSURE) or through the APU.
Subtask 71-51-44-869-051-A ** ON A/C NOT FOR ALL
F. Check the voltage and frequency:
   (1) Start the engine (Ref. AMM TASK 71-00-00-710-003). Let it become stable at the idle speed.
   (2) On the ECAM control panel, get the ELEC page. On the lower display unit of the ECAM system:
  • make sure that the voltage and frequency are correct.
   (3) Stop the engine (Ref. AMM TASK 71-00-00-710-028).
Subtask 71-51-44-869-052-A ** ON A/C NOT FOR ALL
G. Do the EIS stop procedure (Ref. AMM TASK 31-60-00-860-002).
5. Close-up
Subtask 71-51-44-862-050-A ** ON A/C NOT FOR ALL
A. De-energize the aircraft circuits (Ref. AMM TASK 24-41-00-862-002).
Subtask 71-51-44-869-053-A ** ON A/C NOT FOR ALL
B. Depressurize the pneumatic system.
Subtask 71-51-44-410-050-A ** ON A/C NOT FOR ALL
C. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
   (3) FOR [1000EM1] (ENGINE-1)
437AL 438AR
   (4) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (5) Remove the access platform(s).
   (6) Remove the WARNING NOTICE(S).