W DOC AIRBUS | AMM A320F

Removal of the AFT Tie-Rod and Vibration Isolator (APS 3200)


TASK 49-12-53-000-002-A
Removal of the AFT Tie-Rod and Vibration Isolator (APS 3200)


WARNING: DO NOT TOUCH THE APU UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS WHEN YOU DO THE MAINTENANCE TASK(S).
WARNING: LOCK THE MECHANISM OF THE ACCESS DOOR 316AR WITH THE PIP PIN WHEN YOU OPEN THE ACCESS DOOR. THIS WILL PREVENT INJURY.
CAUTION: DO NOT REMOVE MORE THAN ONE APU MOUNT AT A TIME WHEN THE APU IS INSTALLED. THE APU HOIST AND THE REMAINING TWO MOUNTS MUST SUPPORT THE APU WHEN YOU REMOVE AN APU MOUNT.
FIN: 4055KM ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
98A49107504001
1
PROTECTOR-THREADS,APU MOUNTING BOLTS
A1-91-265
1
HOIST-MINILIFT
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
315AL, 316AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 29-00-00-864-001-A
Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action
TASK 49-00-00-480-001-A
Installation of the APU Hoist Tool
TASK 52-41-00-010-001-A
Open the APU Doors for Access
TASK 52-41-21-000-001-A
Removal of APU Access Door 315AL
TASK 52-41-22-000-001-A
Removal of the APU Access Door and the related Door Mechanism
3. Job Set-up
Subtask 49-12-53-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Put the warning notices on panel 25VU to tell persons not to start the APU.
   (2) Energize the ground service network (Ref. AMM TASK 24-41-00-861-002).
   (3) Make sure that the hydraulic systems are depressurized (Ref. AMM TASK 29-00-00-864-001).
Subtask 49-12-53-865-054-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUAPU/APU/CTL2KDL42
121VUAPU/ECB/SPLY1KDL41
Subtask 49-12-53-010-051-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE below the access doors 315AL and 316AR.
   (2) Open the APU access doors 315AL, 316AR. (Ref. AMM TASK 52-41-00-010-001)
   (3) Set the light switch 11LJ to on.
   (4) Remove the APU access doors 315AL 316AR (Ref. AMM TASK 52-41-21-000-001) (Ref. AMM TASK 52-41-22-000-001).
4. Procedure
Subtask 49-12-53-480-051-A ** ON A/C NOT FOR ALL
A. Installation of the HOIST- MINILIFT
WARNING: OBEY THE HOISTING SAFETY PROCEDURES. MAKE SURE THAT THE HOIST IS ASSEMBLED AND ATTACHED CORRECTLY BEFORE YOU PUT A LOAD ON IT. OBEY THE MANUFACTURER'S INSTRUCTIONS WHEN YOU USE THE HOIST. IF THE HOIST IS IN AN INCORRECT CONDITION THE LOAD CAN MOVE ACCIDENTALLY AND KILL PERSONS OR CAUSE INJURY.
WARNING: DO NOT TURN THE HOIST HANDLE MORE THAN 90 DEGREES WHEN THE APU MOUNT BRACKETS ARE TIGHTLY ENGAGED ON THE VIBRATION ISOLATORS. IF YOU TURN THE HOIST HANDLE MORE THAN 90 DEGREES, YOU CAN CAUSE DAMAGE TO THE APU AND THE APU MOUNTS. THEN THE APU CAN FALL AND KILL PERSONS OR CAUSE THEM INJURY.
   (1) Install the A1-91-265 HOIST-MINILIFT (Ref. AMM TASK 49-00-00-480-001)
Subtask 49-12-53-020-051-A ** ON A/C NOT FOR ALL
B. Removal of the Aft Vibration Isolator
   (1) Slowly wind the handle on the APU hoist until the APU hoist-cable is in tension.
   (2) Remove the nut (9) and install the 98A49107504001 PROTECTOR-THREADS,APU MOUNTING BOLTS on the cone bolt.
   (3) Remove and discard the cotter pins (3) and (5).
   (4) Remove the castle nuts (2) and (6), the washers (1) and (7) and the bolts (4)) and (8).
   (5) Remove the tie-rods (12) and (13) from the vibration isolator.
   (6) Remove the vibration isolator (10) from the APU mount-bracket (11).
   (7) If necessary remove the tie-rods (12) and/or (13).
     (a) Remove the nuts (14), the washers (17) and the screws (16).
     (b) Disconnect the bonding straps (15).
     (c) Remove and discard the cotter pins (20).
     (d) Remove the castle nuts (19), the washers (18) and the bolts (21).
     (e) Remove the tie-rods (12) and/or (13).
[Rev.10 from 2021] 2026.04.01 12:42:24 UTC